AJP - Heart pressure measurements
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 242: H392-H404, 1982;
0363-6135/82 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Buy
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Consigny, P. M.
Right arrow Articles by Hoffman, J. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Consigny, P. M.
Right arrow Articles by Hoffman, J. I.

AJP - Heart and Circulatory Physiology, Vol 242, Issue 3 392-H404, Copyright © 1982 by American Physiological Society


ARTICLES

Acute and chronic microsphere loss from canine left ventricular myocardium

P. M. Consigny, E. D. Verrier, B. D. Payne, G. Edelist, J. Jester, R. W. Baer, G. J. Vlahakes and J. I. Hoffman

We determined the effects of time, type of anesthesia, and myocardial infarction on loss of radioactive microspheres averaging 9 or 15 micrometers diameter from left ventricular myocardium. The principle used to compute losses was comparison of the number of microspheres injected directly into coronary arteries to the numbers remaining in myocardium, appearing within 2-4 min in the coronary sinus, or trapped in the lungs. Losses of 9-micrometers microspheres within 2 min of injection were significantly greater for halothane (mean 6.3%) than nitrous oxide anesthesia (mean 3.3%), and in the next 2 h increased to 11.7 and 7.9%, respectively. Over 5 wk in conscious dogs losses were as high as 40 and 11% for 9 and 15 micrometers microspheres, respectively. Losses were not greater for infarcted than normal muscle, and negligible radioactivity appeared in paracardiac lymph nodes. Microspheres leaving the heart were almost all below 10.3 micrometers diameter, so that microspheres with diameters 10-14 (mean 12) micrometers might be the best size to use for myocardial studies.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
E. Thein, M. Becker, H. Anetzberger, C. Hammer, and K. Messmer
Direct assessment and distribution of regional portal blood flow in the pig by means of fluorescent microspheres
J Appl Physiol, November 1, 2003; 95(5): 1808 - 1816.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online