AJP - Heart Watch the video to see how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 246: H754-H760, 1984;
0363-6135/84 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hayes, B. E.
Right arrow Articles by Bisgard, G. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hayes, B. E.
Right arrow Articles by Bisgard, G. E.

AJP - Heart and Circulatory Physiology, Vol 246, Issue 6 754-H760, Copyright © 1984 by American Physiological Society


ARTICLES

Limitations of thermodilution cardiac output measurements in the rat

B. E. Hayes, J. A. Will, W. C. Zarnstorff and G. E. Bisgard

Heat loss from the vascular system could introduce an error in thermodilution cardiac output determinations. Cardiac output measured in the rat via the thermodilution technique following right atrial injection yielded different values (P less than 0.001), depending whether sampling was from the pulmonary artery (460 +/- 31 ml X min-1 X kg-1), right ventricle (311 +/- 19), or thoracic aorta (245 +/- 15). Recirculation errors could not account for the differences. Heat loss from the vascular system was measured from extravascular thermistors within both the thorax and the abdomen. These dilutions were 22-57% in peak height of aortic curves recorded at approximately the same location. Differences in calculated cardiac output between sampling sites could be attributed to rapid heat conduction directly from the right atrium and inferior vena cava to the thoracic aorta with progressive loss of indicator from both the right ventricle and pulmonary artery.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
N. Veal, F. Moal, J. Wang, E. Vuillemin, F. Oberti, E. Roy, M. Kaassis, R. Trouve, J.-L. Saumet, and P. Cales
New method of cardiac output measurement using ultrasound velocity dilution in rats
J Appl Physiol, September 1, 2001; 91(3): 1274 - 1282.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. Vogel
Measurement of cardiac output in small laboratory animals using recordings of blood conductivity
Am J Physiol Heart Circ Physiol, November 1, 1997; 273(5): H2520 - H2527.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online