AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 249: H899-H905, 1985;
0363-6135/85 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fleming, B. P.
Right arrow Articles by Johnson, W. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fleming, B. P.
Right arrow Articles by Johnson, W. O.

AJP - Heart and Circulatory Physiology, Vol 249, Issue 4 899-H905, Copyright © 1985 by American Physiological Society


ARTICLES

Measurement of erythrocyte velocity by use of a periodic differential detector

B. P. Fleming, B. Klitzman and W. O. Johnson

An optical velocimeter employing a linear array of photodiodes has been developed and utilized for measuring erythrocyte velocities in the microcirculation. A magnified image of a microvessel is projected and aligned on a one-dimensional array of photodiodes. Photocurrent from odd-ordered diodes is summed, photocurrent from even-ordered diodes is summed, and a signal proportional to the difference between these two currents is produced by a differential amplifier. The center frequency of the output signal of the differential amplifier is proportional to the erythrocyte velocity. After lowpass filtering the output of the differential amplifier, a signal proportional to its frequency and therefore velocity is produced by a frequency-voltage converter. In vitro calibration with a moving dried smear of erythrocytes illustrated a linear relation between the output of the frequency-voltage converter and erythrocyte velocity for a wide range of velocities and magnifications. The system produces a stable zero output at zero velocity and had an estimated frequency response of greater than 40 Hz in vivo. Volumetric flow rates computed from velocity and diameter measurements at arteriolar bifurcations in the rat cremaster muscle were consistent with mass conservation.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Golub and R. N. Pittman
PO2 measurements in the microcirculation using phosphorescence quenching microscopy at high magnification
Am J Physiol Heart Circ Physiol, June 1, 2008; 294(6): H2905 - H2916.