AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 250: H131-H136, 1986;
0363-6135/86 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heckman, J. L.
Right arrow Articles by Lynch, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heckman, J. L.
Right arrow Articles by Lynch, P. R.

AJP - Heart and Circulatory Physiology, Vol 250, Issue 1 131-H136, Copyright © 1986 by American Physiological Society


ARTICLES

Biplane ventriculography in the rat

J. L. Heckman, L. Garvin, T. Brown, W. Stevenson-Smith, W. P. Santamore and P. R. Lynch

Biplane ventriculography was performed on nine intact anesthetized rats. Images of the left ventricle large enough for analysis were obtained by placing the rats close to the radiographic tubes (direct enlargement). Sampling rates, adequate for heart rates of 500 beats/min, were obtained by filming at 500 frames/s. From the digitized silhouettes of the left ventricle the following information was obtained (means +/- SE): end-diastolic volume 0.60 +/- 0.03 ml, end-systolic volume 0.22 +/- 0.02 ml, stroke volume 0.38 +/- 0.02 ml, ejection fraction 0.63 +/- 0.02, cardiac output 118 +/- 7 ml/min, diastolic septolateral dimension 0.41 +/- 0.01 mm, diastolic anteroposterior dimension 0.40 +/- 0.01 mm, diastolic base-to-apex dimension 1.58 +/- 0.04 mm. To determine the accuracy with which the volume of the ventricle could be measured, 11 methyl methacrylate casts of the left ventricle were made. The correlation was high (r = 0.99 +/- 0.02 ml E) between the cast volumes determined by water displacement and by use of two monoplane methods (Simpson's rule of integration and the area-length method applied to the analysis of the anteroposterior films) and a biplane method (area-length). These results demonstrate that it is possible to obtain accurate dimensions and volumes of the rat left ventricle by use of high-speed ventriculography.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online