AJP - Heart AJP: Renal Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 253: H147-H153, 1987;
0363-6135/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Steinke, J. M.
Right arrow Articles by Shepherd, A. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Steinke, J. M.
Right arrow Articles by Shepherd, A. P.

AJP - Heart and Circulatory Physiology, Vol 253, Issue 1 147-H153, Copyright © 1987 by American Physiological Society


ARTICLES

Reflectance measurements of hematocrit and oxyhemoglobin saturation

J. M. Steinke and A. P. Shepherd

Fiberoptic oximeters measure oxyhemoglobin saturation from the optical reflectance of whole blood, but the calibration of such oximeters is hematocrit dependent. Therefore, using photon-diffusion theory and an empirical approach, we have developed a new reflectance method that determines hematocrit and correspondingly corrects the oxyhemoglobin-saturation measurement. Our method employs four fiber-optic light guides, a photodetector, and three inexpensive light-emitting diodes (one with emissions at 660 nm and two at 813 nm). Hematocrit is determined from the ratio of reflectances from the differently spaced emitting fibers at 813 nm and is used to correct the 813-660 nm measurement of oxyhemoglobin saturation. In red cell suspensions, the mean difference between reflectance measurements of hematocrit and conventional determinations was only 2.09% (r = 0.99), and when compared with conventional gasometric measurements of oxyhemoglobin saturation, the reflectance method yielded the same calibration curve for different hematocrits and gave a mean difference of only 2.67%. Although the technique is demonstrated with a cuvette appropriate for an extracorporeal circulation in animal experiments, it could possibly be further developed for fiber-optic catheter oximeters.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online