AJP - Heart AJP: Heart and Circulatory Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 254: H115-H119, 1988;
0363-6135/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, R. W.
Right arrow Articles by Goldman, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, R. W.
Right arrow Articles by Goldman, S.

AJP - Heart and Circulatory Physiology, Vol 254, Issue 1 115-H119, Copyright © 1988 by American Physiological Society


ARTICLES

Use of acetylcholine to measure total vascular pressure-volume relationship in dogs

R. W. Lee, L. D. Lancaster, R. G. Gay, M. Paquin and S. Goldman
Department of Internal Medicine, Tucson Veterans Administration Medical Center, Arizona 85723.

To define total vascular capacitance, we used acetylcholine to arrest the heart and measured mean circulatory filling pressure (MCFP) during controlled hemorrhage and volume loading in 12 splenectomized dogs after ganglion blockade with hexamethonium. We also examined the gross pathological and histological changes in the lungs. Controlled hemorrhage (n = 12) of 5 and 10 ml/kg decreased MCFP from 6.8 +/- 0.1 to 4.9 +/- 0.3 and 3.6 +/- 0.2 mmHg, respectively. Volume loading of 5 (n = 8) and 10 ml/kg (n = 4) increased MCFP to 9.3 +/- 0.2 and 12.1 +/- 0.1 mmHg, respectively. At MCFPs below 5 mmHg, the pressure (P)-volume (V) relationship was not linear [(P = P0ekV, where k is slope of ln (MCFP) vs. V, k = 0.061, R2 = 0.998]. At MCFPs between 5 and 12 mmHg, the pressure-volume relationship was linear (slope = 0.479 mmHg.ml-1.kg-1, R2 = 0.992) and total vascular compliance was 2.09 ml.mmHg-1.kg-1. There were no changes in heart rate, cardiac output, right atrial, pulmonary artery, and pulmonary artery wedge pressures when values at base line were compared with those measured 15 min after each arrest. There were no changes in arterial gas measurements or acid-base balance, and there was no evidence of atelectasis or interstitial or intra-alveolar edema. We conclude that the total body pressure-volume relationship in the presence of ganglion blockade had a nonlinear configuration. The use of acetylcholine to arrest the heart, four times with hexamethonium in reflex-blocked animals, did not result in changes in hemodynamics or pulmonary function.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. D. Schipke, G. Heusch, A. P. Sanii, E. Gams, and J. Winter
Static filling pressure in patients during induced ventricular fibrillation
Am J Physiol Heart Circ Physiol, December 1, 2003; 285(6): H2510 - H2515.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online