AJP - Heart AJP: Endocrinology and Metabolism
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 257: H681-H689, 1989;
0363-6135/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, M. L.
Right arrow Articles by Corr, P. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, M. L.
Right arrow Articles by Corr, P. B.

AJP - Heart and Circulatory Physiology, Vol 257, Issue 2 681-H689, Copyright © 1989 by American Physiological Society


ARTICLES

A high density in vitro extracellular electrode array: description and implementation

M. L. Cohen, R. H. Hoyt, J. E. Saffitz and P. B. Corr
Cardiovascular Division, Washington University School of Medicine, St. Louis, Missouri 63110.

The detailed activation sequence in myocardium provides information critical to the understanding of the mechanisms of cardiac arrhythmias and the influence of interventions. Despite the pivotal role of activation mapping, the interpretation of isochronic maps and the correlation to detailed tissue morphology may be limited when the interelectrode distances are large with respect to cell dimensions. Additionally, dynamic beat-to-beat variations in the activation pattern or the effect of interventions such as single extra stimuli cannot be assessed adequately without recording from all sites simultaneously. To surmount these limitations, we have fabricated and tested an extracellular recording array consisting of 224 bipolar tungsten wire electrodes with a 350-microns interelectrode distance (140 microns edge-to-edge distance), and used signal processing equipment to record from all electrodes simultaneously at a 2-kHz sample rate. Stimulation can be performed sequentially from 12 different sites at 30 degree angles around the periphery of the recording array. Transarray bipoles can be recorded from any combination of eight radially oriented sites. Activation maps recorded in normal tissue after programmed stimulation and activation maps from an area of fixed anatomic block in the epicardial border zone of infarcted tissue are presented. The results demonstrate a lack of influence of the recording array on the electrophysiological properties of the tissue as verified with transmembrane action potential recordings and sequential extracellular maps. This electrode permits precise assessment of transient details of the activation sequence with unparalleled anatomic resolution.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
R. A. Malkin and B. D. Pendley
Construction of a very high-density extracellular electrode array
Am J Physiol Heart Circ Physiol, July 1, 2000; 279(1): H437 - H442.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. Macchi, M. Cavalieri, D. Stilli, E. Musso, S. Baruffi, G. Olivetti, P. R. Ershler, R. L. Lux, and B. Taccardi
High-density epicardial mapping during current injection and ventricular activation in rat hearts
Am J Physiol Heart Circ Physiol, November 1, 1998; 275(5): H1886 - H1897.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS