AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 258: H1224-H1231, 1990;
0363-6135/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, T. A.
Right arrow Articles by Gettes, L. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, T. A.
Right arrow Articles by Gettes, L. S.

AJP - Heart and Circulatory Physiology, Vol 258, Issue 4 1224-H1231, Copyright © 1990 by American Physiological Society


ARTICLES

Fabrication, evaluation, and use of extracellular K+ and H+ ion-selective electrodes

T. A. Johnson, C. L. Engle, R. P. Kusy, S. B. Knisley, C. A. Graebner and L. S. Gettes
Department of Medicine, School of Medicine, University of North Carolina, Chapel Hill 27599-7075.

Ion-selective mini-electrodes have been widely employed to measure extracellular K+ and H+ during myocardial ischemia. However, the recent availability of this technology has not been accompanied by uniform fabrication, amplification, and calibration standards. In their fabrication, the chloride tips of Teflon-coated silver wires should be covered with a cellulose acetate-titanium dioxide sponge followed by a polyvinyl chloride (PVC)-valinomycin (K+) or PVC-tridodecylamine (H+) ion-selective membrane. Critical analysis of the nonworking electrodes using scanning electron micrographs has revealed membrane holes, membrane and sponge contamination, Teflon plaque, poor membrane-sponge-Teflon adhesion, and improperly applied or torn membrane. We have also found that signal amplification must have variable-gain filtration (0-1 Hz) with 0.5-pA input offset current and 10(12)-omega input resistance. Furthermore, in vitro calibration in 3 and 10 mM KCl (K+) or pH 8 and 6 buffer (H+) should produce a Nernstian slope +/- 5 or 10%, respectively, at 26 degrees C with a response time less than or equal to 50 ms, resistance greater than or equal to 10(12) omega, and drifts less than or equal to 1 mV/h. In vivo performance and calibration criteria (delineated for K+ only) include 1) transient response to bolus injections of KCl (0.12 mM/kg body wt) yielding peak amplitude changes of 2.5-3.0 mM, response times less than or equal to 10 s, and washout time constants less than or equal to 3 min, and 2) in vivo calibration to artificial independently confirmed systemic [K+] producing a Nernstian slope +/- 15% at 38 degrees C.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. Miyata, J. D. Dowell, D. P. Zipes, and M. Rubart
Rate-dependent [K+]o accumulation in canine right atria in vivo: electrophysiological consequences
Am J Physiol Heart Circ Physiol, August 1, 2002; 283(2): H506 - H517.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
Y. K. Skrobik and J. G. Filep
Epi and endomyocardial pH allows the detection of acute right ventricular ischemia in pigs: a new evaluation method: [La connaissance des pH epimyocardique et endomyocardique permet la detection d'ischemie aigue du ventricule droit chez des porcs : une nouvelle methode d'evaluation]
Can J Anesth, January 1, 2002; 49(1): 84 - 89.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
O. M. Sejersted and G. Sjogaard
Dynamics and Consequences of Potassium Shifts in Skeletal Muscle and Heart During Exercise
Physiol Rev, October 1, 2000; 80(4): 1411 - 1481.
[Abstract] [Full Text] [PDF]


Home page
J. Pharmacol. Exp. Ther.Home page
R. Sato, J. Yamazaki, and T. Nagao
Temporal Differences in Actions of Calcium Channel Blockers on K+ Accumulation, Cardiac Function, and High-Energy Phosphate Levels in Ischemic Guinea Pig Hearts
J. Pharmacol. Exp. Ther., May 1, 1999; 289(2): 831 - 839.
[Abstract] [Full Text]


Home page
CirculationHome page
A. Kanda, I. Watanabe, M. L. Williams, C. L. Engle, S. Li, G. G. Koch, and L. S. Gettes
Unanticipated Lessening of the Rise in Extracellular Potassium During Ischemia by Pinacidil
Circulation, April 1, 1997; 95(7): 1937 - 1944.
[Abstract] [Full Text]


Home page
CirculationHome page
L. M. Owens, T. A. Fralix, E. Murphy, W. E. Cascio, and L. S. Gettes
Correlation of Ischemia-Induced Extracellular and Intracellular Ion Changes to Cell-to-Cell Electrical Uncoupling in Isolated Blood-Perfused Rabbit Hearts
Circulation, July 1, 1996; 94(1): 10 - 13.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online