AJP - Heart Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 258: H1573-H1584, 1990;
0363-6135/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Morita, Y.
Right arrow Articles by Kaufman, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morita, Y.
Right arrow Articles by Kaufman, L.

AJP - Heart and Circulatory Physiology, Vol 258, Issue 5 1573-H1584, Copyright © 1990 by American Physiological Society


ARTICLES

Local blood flow measured by fluorescence excitation of nonradioactive microspheres

Y. Morita, B. D. Payne, G. S. Aldea, C. McWatters, W. Husseini, H. Mori, J. I. Hoffman and L. Kaufman
Department of Pediatrics, University of California, San Francisco 94143.

An X-ray fluorescence system with low Compton background and high counting efficiency was developed to measure regional blood flow with nonradioactive microspheres. The performance of the system was tested in vitro by counting mixed aqueous solutions of either Mo, Ag, and I; Nb, Ag, and Ba; or Zr, Mo, Rh, Ag, Sn, I, and Ba, as well as a mixture of Ag and Ba nonradioactive microspheres. Mixtures containing 2-20 ppm of each element were counted for 10 min by the fluorescence system, and the individual elements in mixtures of three to seven nonradioactive elements were measured with high accuracy. The best counting statistics were obtained for Ag. For 10-min counts, the system measures as few as 120 Ag microspheres with 30% standard deviation but measures 800 Ag microspheres per sample with 3.6% standard deviation. We compared regional myocardial blood flows determined simultaneously by fluorescence and radioactive microsphere methods; the latter samples were counted by a 3-in. NaI (Tl) well detector and pulse-height analyzer. The radioactive and nonradioactive measurements showed good correlations.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. Schimmel, D. Frazer, and R. W. Glenny
Extending fluorescent microsphere methods for regional organ blood flow to 13 simultaneous colors
Am J Physiol Heart Circ Physiol, June 1, 2001; 280(6): H2496 - H2506.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. P. Reinhardt, S. Dalhberg, M. A. Tries, R. Marcel, and J. A. Leppo
Stable labeled microspheres to measure perfusion: validation of a neutron activation assay technique
Am J Physiol Heart Circ Physiol, January 1, 2001; 280(1): H108 - H116.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS