AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 261: H349-H353, 1991;
0363-6135/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Adair, T. H.
Right arrow Articles by Guyton, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Adair, T. H.
Right arrow Articles by Guyton, A. C.

AJP - Heart and Circulatory Physiology, Vol 261, Issue 2 349-H353, Copyright © 1991 by American Physiological Society


ARTICLES

Effect of skin concavity on subcutaneous tissue fluid pressure

T. H. Adair, G. A. Vance, J. P. Montani and A. C. Guyton
Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson 39216-4505.

We tested the hypothesis that mechanical factors associated, with a skin concavity can cause the local tissue fluid pressure to become more negative. Perforated Teflon collars, 26 mm in diameter and having various heights (5, 10, 13, and 16 mm), were implanted into the fascial plane of the inguinal and abdominal areas of six sheep. After several weeks, visible signs of edema were no longer apparent, and the skin formed a concavity within the center of each collar. The depth of each concavity was measured using an electronic micrometer, and the tissue fluid pressure beneath the concavity was measured using a needle method. Over the entire range of collar heights, the average depth of the concavities ranged from 1.1 to 4.7 mm in the abdominal tissues and from 1.8 to 5.5 mm in the inguinal tissues. The respective values of tissue fluid pressure averaged -4.6 to -13.0 and -5.7 to -12.8 mmHg. The results therefore indicate that implanting deeper collars leads to the formation of deeper concavities in the skin and also to greater negativity in the free tissue fluid pressure beneath the skin. Linear regression extrapolation to a collar height of 0 mm corresponded to a tissue fluid pressure of -1.0 mmHg in the abdominal tissue and -2.4 mmHg in the inguinal tissues. A model based on excessive pumping of the lymphatic system in the vicinity of a concavity is provided to explain this newly described phenomenon. We conclude that mechanical factors associated with the formation of a skin concavity cause or permit the tissue fluid pressure to reach levels of negativity far greater than those that exist in the absence of a concavity.