AJP - Heart Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 261: H644-H650, 1991;
0363-6135/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loree, H. M.
Right arrow Articles by Lee, R. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Loree, H. M.
Right arrow Articles by Lee, R. T.

AJP - Heart and Circulatory Physiology, Vol 261, Issue 3 644-H650, Copyright © 1991 by American Physiological Society


ARTICLES

Turbulent pressure fluctuations on surface of model vascular stenoses

H. M. Loree, R. D. Kamm, C. M. Atkinson and R. T. Lee
Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge 02139.

Turbulence frequently develops when blood passes through a stenosis. To study the hypothesis that turbulence near a plaque surface can cause pressure fluctuations that may promote plaque rupture, models of intravascular stenoses were studied. Experimental conditions simulated peak flow in the coronary and carotid arteries through a stenosis of 80 or 90% diameter reduction and into a region where the plaque had widened distally to a 50-75% stenosis. For symmetric stenoses at carotid artery flow rates, peak pressure fluctuations were observed 1-1.5 upstream diameters distal to the stenosis, but there were no significant turbulent pressure fluctuations at coronary artery flow rates. Stenosis asymmetry strongly increased the intensity of turbulent pressure fluctuations at flows simulating carotid flow and resulted in significant pressure fluctuations for coronary flow conditions. Increasing stenosis severity from 80 to 90% increased the root mean square pressure fluctuations 3.6-fold. These studies predict peak to peak pressure fluctuations of 15 mmHg in a 90% asymmetric coronary stenosis; it is possible that turbulence may play a role in acute damage of atherosclerotic plaques, particularly in asymmetric stenoses.


This article has been cited by other articles:


Home page
StrokeHome page
S. Meairs and M. Hennerici
Four-Dimensional Ultrasonographic Characterization of Plaque Surface Motion in Patients With Symptomatic and Asymptomatic Carotid Artery Stenosis
Stroke, September 1, 1999; 30(9): 1807 - 1813.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J Ge, F Chirillo, J Schwedtmann, G Görge, M Haude, D Baumgart, V Shah, C von Birgelen, S Sack, H Boudoulas, et al.
Screening of ruptured plaques in patients with coronary artery disease by intravascular ultrasound
Heart, June 1, 1999; 81(6): 621 - 627.
[Abstract] [Full Text]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
E. Lee, A. J. Grodzinsky, P. Libby, S. K. Clinton, M. W. Lark, and R. T. Lee
Human Vascular Smooth Muscle Cell–Monocyte Interactions and Metalloproteinase Secretion in Culture
Arterioscler Thromb Vasc Biol, December 1, 1995; 15(12): 2284 - 2289.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Falk, P. K. Shah, and V. Fuster
Coronary Plaque Disruption
Circulation, August 1, 1995; 92(3): 657 - 671.
[Full Text]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
D. Recchia, D. R. Abendschein, J. E. Saffitz, and S. A. Wickline
The Biologic Behavior of Balloon Hyperinflation–Induced Arterial Lesions in Hypercholesterolemic Pigs Depends on the Presence of Foam Cells
Arterioscler Thromb Vasc Biol, July 1, 1995; 15(7): 924 - 929.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online