AJP - Heart Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 273: H2078-H2082, 1997;
0363-6135/97 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lu, L.
Right arrow Articles by Chou, T. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lu, L.
Right arrow Articles by Chou, T. M.
Vol. 273, Issue 4, H2078-H2082, October 1997

SPECIAL COMMUNICATION
Transesophageal echocardiography in rats using an intravascular ultrasound catheter

Li Lu1, Eitetsu Ko1, Gregory G. Schwartz1,2, and Tony M. Chou1

1 Division of Cardiology and Cardiovascular Research Institute, University of California, San Francisco; and 2 Department of Veterans Affairs Medical Center, San Francisco, California 94143

In vivo assessment of cardiac structure and function in small animals is an important experimental goal, but currently available techniques have significant limitations. A commercially available intravascular ultrasound (IVUS) system was adapted to perform transesophageal echocardiography (TEE) in rats. Twelve Sprague-Dawley rats (270-370 g) were anesthetized with intraperitoneal pentobarbital sodium. A 4.3-Fr, 30-MHz or an 8-Fr, 20-MHz IVUS catheter was inserted into the esophagus to obtain long-axis views of the aortic arch, short-axis views of the ascending aorta, and long-axis views of the pulmonary artery. A preshaped, 8-Fr, 20-MHz catheter was used to obtain short-axis images of the left ventricle (LV) at the midpapillary muscle level, which were used to measure LV diastolic and systolic dimensions (diameters) and to calculate LV mass and fractional shortening. Measurements by TEE were compared with those obtained by transthoracic echocardiography in 6 of 12 rats. Postmortem, the LV was weighed to determine actual LV mass. The correlation coefficients between TEE- and transthoracic echocardiography-calculated LV mass and actual LV mass were 0.94 and 0.88, respectively, and had a good agreement with actual LV mass. Inter- and intraobserver variability of TEE measurements was <10%. IVUS instrumentation may offer an alternative technique for the accurate, serial assessment of LV dimensions, mass, and systolic function and a means of imaging the great vessels in small laboratory animals.

transthoracic echocardiography; left ventricle; mass


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
I. Sjaastad, O. M. Sejersted, A. Ilebekk, and R. Bjornerheim
Echocardiographic criteria for detection of postinfarction congestive heart failure in rats
J Appl Physiol, October 1, 2000; 89(4): 1445 - 1454.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online