AJP - Heart Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 274: H1386-H1392, 1998;
0363-6135/98 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stergiopulos, N.
Right arrow Articles by Westerhof, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stergiopulos, N.
Right arrow Articles by Westerhof, N.
Vol. 274, Issue 4, H1386-H1392, April 1998

MODELING IN PHYSIOLOGY
Physical basis of pressure transfer from periphery to aorta: a model-based study

Nikos Stergiopulos1, Berend E. Westerhof2, and Nico Westerhof3

1 Biomedical Engineering Laboratory, Swiss Federal Institute of Technology, 1015 Lausanne, Switzerland; 2 Biomedical Instrumentation Department, Institute of Applied Physics, Netherlands Organization for Applied Scientific Research, Academic Medical Center, 1105 AZ Amsterdam; and 3 Laboratory for Physiology, Institute for Cardiovascular Research, Free University of Amsterdam, 1081 BT Amsterdam, The Netherlands

We propose a new method to derive aortic pressure from peripheral pressure and velocity by using a time domain approach. Peripheral pressure is separated into its forward and backward components, and these components are then shifted with a delay time, which is the ratio of wave speed and distance, and added again to reconstruct aortic pressure. We tested the method on a distributed model of the human systemic arterial tree. From carotid and brachial artery pressure and velocity, aortic systolic and diastolic pressure could be predicted within 0.3 and 0.1 mmHg and 0.4 and 1.0 mmHg, respectively. The central aortic pressure wave shape was also predicted accurately from carotid and brachial pressure and velocity (root mean square error: 1.07 and 1.56 mmHg, respectively). The pressure transfer function depends on the reflection coefficient at the site of peripheral measurement and the delay time. A 50% decrease in arterial compliance had a considerable effect on reconstructed pressure when the control transfer function was used. A 70% decrease in arm resistance did not affect the reconstructed pressure. The transfer function thus depends on wave speed but has little dependence on vasoactive state. We conclude that central aortic pressure and the transfer function can be derived from peripheral pressure and velocity.

forward and backward waves; wave propagation; reflection coefficient; carotid and brachial arteries


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. Swamy, D. Xu, N. B. Olivier, and R. Mukkamala
An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform
Am J Physiol Heart Circ Physiol, November 1, 2009; 297(5): H1956 - H1963.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Reymond, F. Merenda, F. Perren, D. Rufenacht, and N. Stergiopulos
Validation of a one-dimensional model of the systemic arterial tree
Am J Physiol Heart Circ Physiol, July 1, 2009; 297(1): H208 - H222.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. E. Westerhof, I. Guelen, W. J. Stok, H. A. J. Lasance, C. A. P. L. Ascoop, K. H. Wesseling, N. Westerhof, W. J. W. Bos, N. Stergiopulos, and J. A. E. Spaan
Individualization of transfer function in estimation of central aortic pressure from the peripheral pulse is not required in patients at rest
J Appl Physiol, December 1, 2008; 105(6): 1858 - 1863.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. W. Mohiuddin, G. A. Laine, and C. M. Quick
Increase in pulse wavelength causes the systemic arterial tree to degenerate into a classical windkessel
Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H1164 - H1171.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
J. P. H. M. van den Wijngaard, B. E. Westerhof, D. J. Faber, M. M. Ramsay, N. Westerhof, and M. J. C. van Gemert
Abnormal arterial flows by a distributed model of the fetal circulation
Am J Physiol Regulatory Integrative Comp Physiol, November 1, 2006; 291(5): R1222 - R1233.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. J. Stok, B. E. Westerhof, and J. M. Karemaker
Changes in finger-aorta pressure transfer function during and after exercise
J Appl Physiol, October 1, 2006; 101(4): 1207 - 1214.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J.-J. Wang, A. B. O'Brien, N. G. Shrive, K. H. Parker, and J. V. Tyberg
Time-domain representation of ventricular-arterial coupling as a windkessel and wave system
Am J Physiol Heart Circ Physiol, April 1, 2003; 284(4): H1358 - H1368.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Segers, S. Carlier, A. Pasquet, S. I. Rabben, L. R. Hellevik, E. Remme, T. De Backer, J. De Sutter, J. D. Thomas, and P. Verdonck
Individualizing the aorto-radial pressure transfer function: feasibility of a model-based approach
Am J Physiol Heart Circ Physiol, August 1, 2000; 279(2): H542 - H549.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online