AJP - Heart Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 275: H653-H661, 1998;
0363-6135/98 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Szwarc, R. S.
Right arrow Articles by Ball, H. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Szwarc, R. S.
Right arrow Articles by Ball, H. A.
Vol. 275, Issue 2, H653-H661, August 1998

Simultaneous LV and RV volumes by conductance catheter: effects of lung insufflation on parallel conductance

Richard S. Szwarc and Howard A. Ball

Department of Clinical Pharmacology, Novartis, CH-4002 Basel, Switzerland

One aspect in the measurement of ventricular volume using the conductance catheter technique is the assessment of parallel electrical conductivity of structures extrinsic to the ventricular blood pool. Because it is sometimes necessary to make volume measurements during ventilation or spontaneous respiration, the extent to which parallel conductance may vary with lung insufflation was investigated. Anesthetized pigs (11-15 kg) were ventilated and instrumented with both left (LV) and right ventricular (RV) conductance and pressure-tip catheters and end-hole catheters for injection of hypertonic saline into the inferior vena cava and pulmonary artery. Data were recorded during ventilation with tidal volumes of 10 and 20 ml/kg, and the associated fluctuations to LV and RV end-diastolic (EDV) and stroke (SV) volumes were measured. With the use of a saline dilution technique, parallel conductance (Vc) was determined for each ventricle with the ventilator off and lungs insufflated to 0, 10, and 20 ml/kg. Whereas ventilation caused marked oscillations in LV and RV EDV and SV, these variations could not be attributed to Vc, which remained statistically unchanged from their baseline values of 34.1 ± 3.1 in the LV and 31.1 ± 4.4 in the RV. These results indicate that the fluctuations that occur in conductance catheter-derived LV and RV volume signals with ventilation are not caused by any significant changes to parallel conductance.

conductance catheter; ventricular volume; ventricular interaction; parallel conductance


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. H. D. Danton, G. F. Greil, J. G. Byrne, M. Hsin, L. Cohn, and S. E. Maier
Right ventricular volume measurement by conductance catheter
Am J Physiol Heart Circ Physiol, October 1, 2003; 285(4): H1774 - H1785.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. D. Feldman, J. M. Erikson, Y. Mao, C. E. Korcarz, R. M. Lang, and G. L. Freeman
Validation of a mouse conductance system to determine LV volume: comparison to echocardiography and crystals
Am J Physiol Heart Circ Physiol, October 1, 2000; 279(4): H1698 - H1707.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online