AJP - Heart Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 275: H1419-H1433, 1998;
0363-6135/98 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Osaka, M.
Right arrow Articles by Hayakawa, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Osaka, M.
Right arrow Articles by Hayakawa, H.
Vol. 275, Issue 4, H1419-H1433, October 1998

Mutual information discloses relationship between hemodynamic variables in artificial heart-implanted dogs

Motohisa Osaka, Tomoyuki Yambe, Hirokazu Saitoh, Makoto Yoshizawa, Takashi Itoh, Shin-Ichi Nitta, Hiroshi Kishida, and Hirokazu Hayakawa

First Department of Internal Medicine and Center of Informatics Science, Nippon Medical School, Tokyo 113-8603; Department of Medical Engineering and Cardiology, Division of Organ Pathology, Institute of Development, Aging, and Cancer, and Department of Electrical Engineering, Faculty of Engineering, Tohoku University, Sendai 980-8575, Japan

A mutual information (MI) method for assessment of the relationship between hemodynamic variables was proposed and applied to the analysis of heart rate (HR), arterial blood pressure (BP), and renal sympathetic nerve activity (RSNA) in artificial heart-implanted dogs to quantify correlation between these parameters. MI measures the nonlinear as well as linear dependence of two variables. Simulation studies revealed that this MI technique furnishes mathematical features well suited to the investigation of nonlinear dynamics such as the cardiovascular system and can quantify a relationship between two parameters. To constitute a model free of the natural heart, two pneumatically actuated ventricular assist devices were implanted as biventricular bypasses in acute canine experiments. RSNA was detected with the use of bipolar electrodes attached to the renal sympathetic nerve. Analysis of data during control revealed that correlation between HR and RSNA was higher than that between HR and BP and that between RSNA and BP (P < 0.05). Although RSNA seemed to fluctuate noncorrelatedly with BP in higher pacing rates, the MI values between them disclosed their strong correlation. Surprisingly, correlation between RSNA and BP was stronger during a pacing rate of 60 beats/min than during higher pacing rates and control (P < 0.05). It is suggested that the baroreflex system may be susceptible to pacing rates during the total artificial heart state. We calculated the time delay between HR and RSNA, between RSNA and BP, and between HR and BP by regarding a time delay at which the maximum MI value between each pair of parameters was given as a physiological delay. Our results indicate that RSNA leads BP, BP leads HR, and RSNA leads HR during control (P < 0.05). We conclude that this method could provide a powerful means for measuring correlation of physiological variables.

cardiovascular regulation; autonomic nervous system; nonlinear dynamics; spectral analysis; computer simulation





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online