AJP - Heart Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 280: H475-H482, 2001;
0363-6135/01 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, P. A.
Right arrow Articles by Redington, A. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, P. A.
Right arrow Articles by Redington, A. N.
Vol. 280, Issue 1, H475-H482, January 2001

SPECIAL COMMUNICATION
Validation and utility of novel volume reduction technique for determination of parallel conductance

Paul A. White1, Carl I. O. Brookes2, Hanne Ravn3, Vibeke Hjortdal3, Rajiv R. Chaturvedi1, and Andrew N. Redington1

1 Cardiothoracic Unit, Great Ormond Street Hospital For Children, London WC1N 3JH; 2 Department of Cardiology, Royal Brompton Hospital, London SW3 6NP, United Kingdom; and 3 Institute of Experimental Clinical Research, Skejby University Hospital, DK-8200 Aarhus N, Denmark

The parallel conductance volume, created by the conductivity of structures surrounding the ventricular blood pool, can be estimated by using a saline dilution technique. This paper examines the use of a novel volume reduction method, during a standard vena caval preload reduction maneuver, as an alternative to the routinely used saline dilution method to calibrate conductance catheter measurements in the left (LV) and right ventricle (RV) of animals and humans. The serial reproducibility of both methods was examined by measurement of percent difference, and by assessing the coefficient of repeatability 1) between two measurements within the same subject, 2) between the two techniques, and 3) interobserver variability. The effect of ventricular size and contractile state on the volume reduction technique was also observed. It was essential to ensure the technique was not affected by inotropic state. The volume reduction technique and saline dilution method were repeated at three different loading states (baseline, 5, and 10 µg · kg-1 · min-1 of dobutamine). The coefficient of repeatability between serial measurements was similar for both the volume reduction and saline dilution methods, and good interobserver variability was demonstrated. The volume reduction technique was compared with the saline dilution technique over a large range of ventricular sizes. No significant difference was observed in the RV or LV of adult humans or in the LV of neonatal pigs and children. There was no significant effect on either the saline dilution or the volume reduction technique as the inotropic state increased. In conclusion, the volume reduction technique is neither affected by ventricular size nor contractile state, is repeatable between different observers, and can be used to substitute the saline dilution method when preload reduction of the ventricle is being employed.

saline dilution; right ventricle; left ventricle; ventricular volume; conductance catheter


This article has been cited by other articles:


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
K. M. Shioura, D. L. Geenen, and P. H. Goldspink
Sex-related changes in cardiac function following myocardial infarction in mice
Am J Physiol Regulatory Integrative Comp Physiol, August 1, 2008; 295(2): R528 - R534.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. M. Shioura, D. L. Geenen, and P. H. Goldspink
Assessment of cardiac function with the pressure-volume conductance system following myocardial infarction in mice
Am J Physiol Heart Circ Physiol, November 1, 2007; 293(5): H2870 - H2877.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. J. Faber, M. Dalinghaus, I. M. Lankhuizen, P. Steendijk, W. C. Hop, R. G. Schoemaker, D. J. Duncker, J. M. J. Lamers, and W. A. Helbing
Right and left ventricular function after chronic pulmonary artery banding in rats assessed with biventricular pressure-volume loops
Am J Physiol Heart Circ Physiol, October 1, 2006; 291(4): H1580 - H1586.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. Brimioulle, P. Wauthy, P. Ewalenko, B. Rondelet, F. Vermeulen, F. Kerbaul, and R. Naeije
Single-beat estimation of right ventricular end-systolic pressure-volume relationship
Am J Physiol Heart Circ Physiol, May 1, 2003; 284(5): H1625 - H1630.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Steendijk, E. Staal, J. W. Jukema, and J. Baan
Hypertonic saline method accurately determines parallel conductance for dual-field conductance catheter
Am J Physiol Heart Circ Physiol, August 1, 2001; 281(2): H755 - H763.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online