1 Department of Bioengineering, University of California, La Jolla 92093-0412; and 2 Department of Radiological Science, University of California, Irvine, California 92697-5000
We have determined the cross-sectional area (CSA) compliance of the first several generations of pig coronary arteries and the volume compliance of the coronary arterial tree (vessels >0.5 mm in diameter) using a videodensitometric technique. The coronary arteries of four KCl-arrested maximally vasodilated pig hearts were perfused with iodine and 3% Cab-O-Sil. Because Cab-O-Sil occludes small arteries, the flow can be stopped and the pressure can be maintained while the trunk of the coronary artery and its subbranches are imaged using digital angiography. The coronary arteries were preconditioned several times with cyclic changes in pressure from 0 to 160 mmHg. The pressure was then varied in a triangular pattern, and the absolute CSA of each vessel and the total arterial volume were calculated using videodensitometry in conjunction with digital subtraction angiography. Our results have shown that the pressure-diameter and pressure-volume relationships are linear in the 60-140 mmHg pressure range. Furthermore, the compliance of the coronary arteries is small; i.e., the diameter of the coronary artery changes by <15% in the 80-mmHg pressure range. The compliance data couples the mechanics of the blood vessel wall to the mechanics of blood flow to yield a pressure-flow relationship for each coronary arterial segment.
distensibility; pressure-diameter relationship; digital subtraction angiography; videodensitometry
This article has been cited by other articles:
![]() |
Y. Huo and G. S. Kassab Pulsatile blood flow in the entire coronary arterial tree: theory and experiment Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1074 - H1087. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Rogers, T. Kiyooka, and W. M. Chilian Is there a need for another model on the pulsatile nature of coronary blood flow? Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1034 - H1035. [Full Text] [PDF] |
||||
![]() |
G. S. Kassab Scaling laws of vascular trees: of form and function Am J Physiol Heart Circ Physiol, February 1, 2006; 290(2): H894 - H903. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Kassab Functional hierarchy of coronary circulation: direct evidence of a structure-function relation Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2559 - H2565. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Kalsho and G. S. Kassab Bifurcation asymmetry of the porcine coronary vasculature and its implications on coronary flow heterogeneity Am J Physiol Heart Circ Physiol, December 1, 2004; 287(6): H2493 - H2500. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Guo and G. S. Kassab Distribution of stress and strain along the porcine aorta and coronary arterial tree Am J Physiol Heart Circ Physiol, June 1, 2004; 286(6): H2361 - H2368. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Lu, J. Yang, J. B. Zhao, H. Gregersen, and G. S. Kassab Shear modulus of porcine coronary artery: contributions of media and adventitia Am J Physiol Heart Circ Physiol, November 1, 2003; 285(5): H1966 - H1975. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. Hamza, Q. Dang, X. Lu, A. Mian, S. Molloi, and G. S. Kassab Effect of passive myocardium on the compliance of porcine coronary arteries Am J Physiol Heart Circ Physiol, July 11, 2003; 285(2): H653 - H660. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |