AJP - Heart AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 281: H755-H763, 2001;
0363-6135/01 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (35)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Steendijk, P.
Right arrow Articles by Baan, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Steendijk, P.
Right arrow Articles by Baan, J.
Vol. 281, Issue 2, H755-H763, August 2001

Hypertonic saline method accurately determines parallel conductance for dual-field conductance catheter

Paul Steendijk, Eva Staal, J. Wouter Jukema, and Jan Baan

Department of Cardiology, Leiden University Medical Center, 2300 RC Leiden, The Netherlands

Conversion of conductance catheter data to absolute ventricular volumes requires assessment of parallel conductance (GP). We determined the accuracy of GP obtained by the hypertonic saline method (G<UP><SUB>saline</SUB><SUP>P</SUP></UP>) compared with angiographically derived GP (G<UP><SUB>Angio</SUB><SUP>P</SUP></UP>) and quantified the variabilities of GP for the dual-field conductance catheter method in nine anesthetized sheep studied at baseline, treated with dobutamine, and subjected to volume loading and beta -blockade. G<UP><SUB>saline</SUB><SUP>P</SUP></UP> and G<UP><SUB>Angio</SUB><SUP>P</SUP></UP> showed an excellent linear correlation (G<UP><SUB>saline</SUB><SUP>P</SUP></UP> = 1.002 · G<UP><SUB>Angio</SUB><SUP>P</SUP></UP> + 0.001 Omega -1, R2 = 0.92), and Bland-Altman analysis yielded a nonsignificant bias and narrow limits of agreement (bias ± 2SD = 0.002 ± 0.112 Omega -1). Within-animal variability of GP was very similar with both methods and was due to changes in blood conductivity rather than geometrical changes. Variability between animals was significant (26.3% of mean for G<UP><SUB>saline</SUB><SUP>P</SUP></UP> and 25.7% for G<UP><SUB>Angio</SUB><SUP>P</SUP></UP>) and thus warrants individual assessment. Variations during the cardiac cycle were not significantly different from zero. With biplane angiography used as gold standard, the hypertonic saline method accurately determines GP for the dual-field conductance catheter over a wide range of hemodynamic conditions.

angiography; left ventricular volume; sheep; ventricular function


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
R. Bauer, G.A. MacGowan, A. Blain, K. Bushby, and V. Straub
Steroid treatment causes deterioration of myocardial function in the {delta}-sarcoglycan-deficient mouse model for dilated cardiomyopathy
Cardiovasc Res, September 1, 2008; 79(4): 652 - 661.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Westermann, M. Kasner, P. Steendijk, F. Spillmann, A. Riad, K. Weitmann, W. Hoffmann, W. Poller, M. Pauschinger, H.-P. Schultheiss, et al.
Role of Left Ventricular Stiffness in Heart Failure With Normal Ejection Fraction
Circulation, April 22, 2008; 117(16): 2051 - 2060.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Missant, S Rex, P Claus, L Mertens, and P F Wouters
Load-sensitivity of regional tissue deformation in the right ventricle: isovolumic versus ejection-phase indices of contractility
Heart, April 1, 2008; 94(4): e15 - e15.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Fannelop, G. O. Dahle, K. Matre, C. A. Moen, A. Mongstad, F. Eliassen, L. Segadal, and K. Grong
Esmolol before 80 min of cardiac arrest with oxygenated cold blood cardioplegia alleviates systolic dysfunction. An experimental study in pigs
Eur. J. Cardiothorac. Surg., January 1, 2008; 33(1): 9 - 17.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. Konrad, M. Haney, G. Johansson, M. Wanecek, E. Weitzberg, and A. Oldner
Cardiac effects of endothelin receptor antagonism in endotoxemic pigs
Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H988 - H996.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. Timmers, J. P.G. Sluijter, C. W.J. Verlaan, P. Steendijk, M. J. Cramer, M. Emons, C. Strijder, P. F. Grundeman, S. K. Sze, L. Hua, et al.
Cyclooxygenase-2 Inhibition Increases Mortality, Enhances Left Ventricular Remodeling, and Impairs Systolic Function After Myocardial Infarction in the Pig
Circulation, January 23, 2007; 115(3): 326 - 332.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. A.F. Tulner, P. Steendijk, R. J.M. Klautz, J. J. Bax, M. J. Schalij, E. E. van der Wall, and R. A.E. Dion
Surgical ventricular restoration in patients with ischemic dilated cardiomyopathy: Evaluation of systolic and diastolic ventricular function, wall stress, dyssynchrony, and mechanical efficiency by pressure-volume loops.
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 610 - 620.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Steendijk, S. A. Tulner, J. J. Bax, P. V. Oemrawsingh, G. B. Bleeker, L. van Erven, H. Putter, H. F. Verwey, E. E. van der Wall, and M. J. Schalij
Hemodynamic Effects of Long-Term Cardiac Resynchronization Therapy: Analysis by Pressure-Volume Loops
Circulation, March 14, 2006; 113(10): 1295 - 1304.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
M. F. Haney, G. Johansson, S. Haggmark, B. Biber, M. F. Haney, G. Johansson, S. Haggmark, and B. Biber
Myocardial Systolic Function Increases During Positive Pressure Lung Inflation
Anesth. Analg., November 1, 2005; 101(5): 1269 - 1274.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. Konrad, A. Oldner, M. Wanecek, A. Rudehill, E. Weitzberg, B. Biber, G. Johansson, S. Haggmark, and M. Haney
Positive inotropic and negative lusitropic effects of endothelin receptor agonism in vivo
Am J Physiol Heart Circ Physiol, October 1, 2005; 289(4): H1702 - H1709.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. F. Royse and A. G. Royse
The Myocardial and Vascular Effects of Bupivacaine, Levobupivacaine, and Ropivacaine Using Pressure Volume Loops
Anesth. Analg., September 1, 2005; 101(3): 679 - 687.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. L. Gaynor, H. S. Maniar, J. B. Bloch, P. Steendijk, and M. R. Moon
Right Atrial and Ventricular Adaptation to Chronic Right Ventricular Pressure Overload
Circulation, August 30, 2005; 112(9_suppl): I-212 - I-218.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. A.F. Tulner, P. Steendijk, R. J.M. Klautz, J. J. Bax, M. I.M. Versteegh, E. E. van der Wall, and R. A.E. Dion
Acute hemodynamic effects of restrictive mitral annuloplasty in patients with end-stage heart failure: Analysis by pressure-volume relations
J. Thorac. Cardiovasc. Surg., July 1, 2005; 130(1): 33 - 40.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. L. Gaynor, H. S. Maniar, S. M. Prasad, P. Steendijk, and M. R. Moon
Reservoir and conduit function of right atrium: impact on right ventricular filling and cardiac output
Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2140 - H2145.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. A.F. Tulner, R. J.M. Klautz, F. H.M. Engbers, J. J. Bax, J. Baan, E. E. van der Wall, R. A.E. Dion, and P. Steendijk
Left ventricular function and chronotropic responses after normothermic cardiopulmonary bypass with intermittent antegrade warm blood cardioplegia in patients undergoing coronary artery bypass grafting
Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 599 - 605.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R.A. Bleasdale, M.S. Turner, C.E. Mumford, P. Steendijk, V. Paul, J.V. Tyberg, J.A. Morris-Thurgood, and M.P. Frenneaux
Left Ventricular Pacing Minimizes Diastolic Ventricular Interaction, Allowing Improved Preload-Dependent Systolic Performance
Circulation, October 19, 2004; 110(16): 2395 - 2400.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
P. Steendijk, S. A.F. Tulner, M. Wiemer, R. A. Bleasdale, J. J. Bax, E. E. van der Wall, J. Vogt, and M. J. Schalij
Pressure-volume measurements by conductance catheter during cardiac resynchronization therapy
Eur. Heart J. Suppl., August 1, 2004; 6(suppl_D): D35 - D42.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. A. F. Tulner, R. J. M. Klautz, G. L. van Rijk-Zwikker, F. H. M. Engbers, J. J. Bax, J. Baan, E. E. van der Wall, R. A. Dion, and P. Steendijk
Perioperative Assessment of Left Ventricular Function by Pressure-Volume Loops Using the Conductance Catheter Method
Anesth. Analg., October 1, 2003; 97(4): 950 - 957.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Segers, V. Tchana-Sato, H. A. Leather, B. Lambermont, A. Ghuysen, J.-M. Dogne, P. Benoit, P. Morimont, P. F. Wouters, P. Verdonck, et al.
Determinants of left ventricular preload-adjusted maximal power
Am J Physiol Heart Circ Physiol, June 1, 2003; 284(6): H2295 - H2301.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. S. Maniar, S. M. Prasad, S. L. Gaynor, C. M. Chu, P. Steendijk, and M. R. Moon
Impact of pericardial restraint on right atrial mechanics during acute right ventricular pressure load
Am J Physiol Heart Circ Physiol, January 1, 2003; 284(1): H350 - H357.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online