AJP - Heart Calcium Transients and Cell-Sarcomere
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 285: H2614-H2622, 2003; doi:10.1152/ajpheart.00567.2003
0363-6135/03 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (18)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guo, X.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guo, X.
Right arrow Articles by Kassab, G. S.

Variation of mechanical properties along the length of the aorta in C57bl/6 mice

Xiaomei Guo and Ghassan S. Kassab

Department of Biomedical Engineering, University of California, Irvine, California 92697-2715

Submitted 13 June 2003 ; accepted in final form 16 August 2003

The objective of the present study is to obtain a systematic set of data on the mechanical properties along the entire length of the mouse aorta. The ascending aorta of seven mice was cannulated near the aortic valve, and the aorta was preconditioned with several cyclic changes in pressure. The perfusion pressure was then increased in 30-mmHg increments from 0 to 150 mmHg. Cab-O-Sil, colloidal silica, was mixed into the perfusate to prevent flow through the microvessels and hence attain zero-flow distensions. Our results show that the residual circumferential strain leads to a uniformity of transmural strain of the aorta in the loaded state along the entire length of the aorta. This uniformity is attained in the range of 60–120 mmHg. At pressures <60 mmHg, the outer strain is greater than the inner strain, whereas at pressures >120 mmHg, the converse is true. Furthermore, we found that the circumferential and longitudinal stress-strain relationships are linear in the pressure range of 30–120 mmHg. Finally, the circumferential modulus is greatest (most rigid) near the diaphragm, and the majority of volume compliance (85%) is in the thoracic compared with the abdominal aorta. These findings are important for an understanding of the hemodynamics of the cardiovascular system of the normal mouse and will serve as a reference state for the study of various diseases in knock-in and knock-out models of this species.

stress; strain; elastic modulus; zero-stress state; strain energy function



Address for reprint requests and other correspondence: G. S. Kassab, Dept. of Biomedical Engineering, Univ. of California, Irvine, 204 Rockwell Engineering Center, Irvine, CA 92697-2715 (E-mail: gkassab{at}uci.edu).




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
E. U. Azeloglu, M. B. Albro, V. A. Thimmappa, G. A. Ateshian, and K. D. Costa
Heterogeneous transmural proteoglycan distribution provides a mechanism for regulating residual stresses in the aorta
Am J Physiol Heart Circ Physiol, March 1, 2008; 294(3): H1197 - H1205.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
X. Guo, Y. Lanir, and G. S. Kassab
Effect of osmolarity on the zero-stress state and mechanical properties of aorta
Am J Physiol Heart Circ Physiol, October 1, 2007; 293(4): H2328 - H2334.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. W. Dye, R. L. Gleason, E. Wilson, and J. D. Humphrey
Altered biomechanical properties of carotid arteries in two mouse models of muscular dystrophy
J Appl Physiol, August 1, 2007; 103(2): 664 - 672.
[Abstract] [Full Text] [PDF]


Home page
J R Soc InterfaceHome page
G. S Kassab
Biomechanics of the cardiovascular system: the aorta as an illustratory example
J R Soc Interface, December 22, 2006; 3(11): 719 - 740.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
X. Guo, M. J. Oldham, M. T. Kleinman, R. F. Phalen, and G. S. Kassab
Effect of cigarette smoking on nitric oxide, structural, and mechanical properties of mouse arteries
Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2354 - H2361.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Y. Huang, X. Guo, and G. S. Kassab
Axial nonuniformity of geometric and mechanical properties of mouse aorta is increased during postnatal growth
Am J Physiol Heart Circ Physiol, February 1, 2006; 290(2): H657 - H664.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. E. Wagenseil, N. L. Nerurkar, R. H. Knutsen, R. J. Okamoto, D. Y. Li, and R. P. Mecham
Effects of elastin haploinsufficiency on the mechanical behavior of mouse arteries
Am J Physiol Heart Circ Physiol, September 1, 2005; 289(3): H1209 - H1217.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2003 by the American Physiological Society.