AJP - Heart Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 287: H985-H993, 2004. First published May 6, 2004; doi:10.1152/ajpheart.00574.2003
0363-6135/04 $5.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
287/3/H985    most recent
00574.2003v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (7)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tai, D. C.-S.
Right arrow Articles by Smaill, B. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tai, D. C.-S.
Right arrow Articles by Smaill, B. H.

TRANSLATIONAL PHYSIOLOGY

Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts

Dean C.-S. Tai, Bryan J. Caldwell, Ian J. LeGrice, Darren A. Hooks, Andrew J. Pullan, and Bruce H. Smaill

Bioengineering Institute, The University of Auckland, Auckland, New Zealand

Submitted 18 June 2003 ; accepted in final form 27 April 2004

Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the time decay in simultaneously acquired short- and long-wavelength signals is characterized nonparametrically and removed. Motion artifact is then identified as the time-varying signal component common to both decay-corrected signals and subtracted. Performance of this subtraction technique was compared with ratiometry for intramural optical signals acquired with a fiber-optic probe in an isolated, Langendorff-perfused pig heart preparation (n = 4) stained with di-4-ANEPPS. Perfusate concentration of 2,3-butanedione monoxime was adjusted (7.5–12.5 mM) to alter contractile activity. Short-wavelength (520–600 nm) and long-wavelength (>600 nm) signals were recorded over 8–16 cardiac cycles at 6 sites across the left ventricular free wall in sinus rhythm and during pacing. A total of 451 such data sets were acquired. Appreciable wall motion was observed in 225 cases, with motion artifact classed as moderate (less than modulation due to action potential) in 187 and substantial (more than modulation due to action potential) in 38. In all cases, subtraction performed as well as, or better than, ratiometry in removing motion artifact and decay. Action potential morphology was recovered more faithfully by subtraction than by ratiometry in 58 of 187 and 31 of 38 cases with moderate and substantial motion artifact, respectively. This novel subtraction approach may therefore provide a means of reducing the concentration of uncoupling agents used in cardiac optical mapping studies.

fluorescence; cardiac electrical mapping



Address for reprint requests and other correspondence: B. H. Smaill, Bioengineering Institute, The Univ. of Auckland, Private Bag 92019, Auckland, New Zealand (E-mail: b.smaill{at}auckland.ac.nz).




This article has been cited by other articles:


Home page
Cardiovasc ResHome page
S. Nishimura, Y. Kawai, T. Nakajima, Y. Hosoya, H. Fujita, M. Katoh, H. Yamashita, R. Nagai, and S. Sugiura
Membrane potential of rat ventricular myocytes responds to axial stretch in phase, amplitude and speed-dependent manners
Cardiovasc Res, December 1, 2006; 72(3): 403 - 411.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2004 by the American Physiological Society.