|
|
||||||||
) in hamster window chamber
1Department of Bioengineering, University of California-San Diego, La Jolla, California 92093; and 2Departments of Medicine and of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, New York 10461
Submitted 17 February 2004 ; accepted in final form 3 June 2004
The oxygen transport capacity of nonhypertensive polyethylene glycol (PEG)-conjugated hemoglobin solutions were investigated in the hamster chamber window model. Microvascular measurements were made to determine oxygen delivery in conditions of extreme hemodilution [hematocrit (Hct) 11%]. Two isovolemic hemodilution steps were performed with a 6% Dextran 70 (70-kDa molecular mass) plasma expander until Hct was 35% of control. Isovolemic blood volume exchange was continued using two surface-modified PEGylated hemoglobins (P5K2, P50 = 8.6, and P10K2, P50 = 8.3; P50 is the hemoglobin PO2 corresponding to its 50% oxygen saturation) until Hct was 11%. P5K2 and P10K2 are PEG-conjugated hemoglobins that maintain most of the hemoglobin allosteric properties and have a cooperativity index of n = 2.2. The effects of these molecular solutions were compared with those obtained in a previous study using MP4, a PEG-modified hemoglobin whose P50 was 5.4 and cooperativity was 1.2 (Tsai et al., Am J Physiol Heart Circ Physiol 285: H1411H1419, 2003). Tissue oxygen levels were higher after P5K2 (7.0 ± 2.5 mmHg) and P10K2 (6.3 ± 2.3 mmHg) versus MP4 (1.7 ± 0.5 mmHg) or the nonoxygen carrier Dextran 70 (1.3 ± 1.2 mmHg). Microvascular oxygen delivery was higher after P5K2 and P10K2 (2.22 and 2.34 ml O2/dl blood) compared with MP4 (1.41 ml O2/dl blood) or Dextran 70 (0.90 ml O2/dl blood); however, all these values were lower than control (7.42 ml O2/dl blood). The total hemoglobin in blood was similar in all cases; therefore, the improvement in tissue PO2 and oxygen delivery appears to be due to the increased cooperativity of the new molecules.
surface-modified hemoglobin; functional capillary density; oxygen-carrying capacity; blood substitutes; tissue oxygen delivery; hemoglobin cooperativity
This article has been cited by other articles:
![]() |
P. Cabrales and A. G. Tsai Plasma viscosity regulates systemic and microvascular perfusion during acute extreme anemic conditions Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2445 - H2452. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cabrales, J. Martini, M. Intaglietta, and A. G. Tsai Blood viscosity maintains microvascular conditions during normovolemic anemia independent of blood oxygen-carrying capacity Am J Physiol Heart Circ Physiol, August 1, 2006; 291(2): H581 - H590. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cabrales, A. G. Tsai, R. M. Winslow, and M. Intaglietta Extreme hemodilution with PEG-hemoglobin vs. PEG-albumin Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2392 - H2400. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cabrales, A. G. Tsai, R. M. Winslow, and M. Intaglietta Effects of extreme hemodilution with hemoglobin-based O2 carriers on microvascular pressure Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2146 - H2153. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cabrales, A. G. Tsai, and M. Intaglietta Alginate plasma expander maintains perfusion and plasma viscosity during extreme hemodilution Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1708 - H1716. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cabrales, H. Sakai, A. G. Tsai, S. Takeoka, E. Tsuchida, and M. Intaglietta Oxygen transport by low and normal oxygen affinity hemoglobin vesicles in extreme hemodilution Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1885 - H1892. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |