1School of Fundamental Science and Technology, 2Institute of Biomedical Engineering, 3Keio Leading-Edge Laboratory of Science and Technology, and 4Department of System Design Engineering Keio University, Yokohama 223-8522; and 5Department of Mechanical Engineering, Shibaura Institute of Technology, Tokyo 108-8548, Japan
Submitted 21 August 2003 ; accepted in final form 13 July 2004
The glycocalyx layer on the surface of an endothelial cell is an interface barrier for uptake of macromolecules, such as low-density lipoprotein and albumin, in the cell. The shear-dependent uptake of macromolecules thus might govern the function of the glycocalyx layer. We therefore studied the effect of glycocalyx on the shear-dependent uptake of macromolecules into endothelial cells. Bovine aorta endothelial cells were exposed to shear stress stimulus ranging from 0.5 to 3.0 Pa for 48 h. The albumin uptake into the cells was then measured using confocal laser scanning microscopy, and the microstructure of glycocalyx was observed using electron microscopy. Compared with the uptake into endothelial cells under static conditions (no shear stress stimulus), the albumin uptake at a shear stress of 1.0 Pa increased by 16% and at 3.0 Pa decreased by 27%. Compared with static conditions, the thickness of the glycocalyx layer increased by 70% and the glycocalyx charge increased by 80% at a shear stress of 3.0 Pa. The albumin uptake at a shear stress of 3.0 Pa for cells with a neutralized (no charge) glycocalyx layer was almost twice that of cells with charged layer. These findings indicate that glycocalyx influences the albumin uptake at higher shear stress and that glycocalyx properties (thickness and charge level) are involved with the shear-dependent albumin uptake process.
blood flow; shear stress; glycocalyx charge; glycocalyx thickness; in vitro model
This article has been cited by other articles:
![]() |
Y. Yao, A. Rabodzey, and C. F. Dewey Jr. Glycocalyx modulates the motility and proliferative response of vascular endothelium to fluid shear stress Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H1023 - H1030. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Sun, N. B. Wood, A. D. Hughes, S. A. M. Thom, and X. Yun Xu Effects of transmural pressure and wall shear stress on LDL accumulation in the arterial wall: a numerical study using a multilayered model Am J Physiol Heart Circ Physiol, June 1, 2007; 292(6): H3148 - H3157. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |