Am J Physiol Heart Circ Physiol 292: H2257-H2264, 2007. First published January 5, 2007; doi:10.1152/ajpheart.01159.2006
0363-6135/07 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
292/5/H2257    most recent
01159.2006v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (4)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swamy, G.
Right arrow Articles by Mukkamala, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swamy, G.
Right arrow Articles by Mukkamala, R.

Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms

Gokul Swamy, Qi Ling, Tongtong Li, and Ramakrishna Mukkamala

Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan

Submitted 21 October 2006 ; accepted in final form 2 January 2007

We have developed a new technique to estimate the clinically relevant aortic pressure waveform from multiple, less invasively measured peripheral artery pressure waveforms. The technique is based on multichannel blind system identification in which two or more measured outputs (peripheral artery pressure waveforms) of a single-input, multi-output system (arterial tree) are mathematically analyzed so as to reconstruct the common unobserved input (aortic pressure waveform) to within an arbitrary scale factor. The technique then invokes Poiseuille's law to calibrate the reconstructed waveform to absolute pressure. Consequently, in contrast to previous related efforts, the technique does not utilize a generalized transfer function or any training data and is therefore entirely patient and time specific. To demonstrate proof of concept, we have evaluated the technique with respect to four swine in which peripheral artery pressure waveforms from the femoral and radial arteries and a reference aortic pressure waveform from the descending thoracic aorta were simultaneously measured during diverse hemodynamic interventions. We report that the technique reliably estimated the entire aortic pressure waveform with an overall root mean squared error (RMSE) of 4.6 mmHg. For comparison, the average overall RMSE between the peripheral artery pressure and reference aortic pressure waveforms was 8.6 mmHg. Thus the technique reduced the RMSE by 47%. As a result, the technique also provided similar improvements in the estimation of systolic pressure, pulse pressure, and the ejection interval. With further successful testing, the technique may ultimately be employed for more precise monitoring and titration of therapy in, for example, critically ill and hypertension patients.

arterial tree; blood pressure; model; system identification; transfer function



Address for reprint requests and other correspondence: Prof. R. Mukkamala, Dept. of Electrical and Computer Engineering, Michigan State Univ., 2120 Engineering Bldg., East Lansing, MI 48824 (e-mail: rama{at}egr.msu.edu)




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. Swamy, D. Xu, N. B. Olivier, and R. Mukkamala
An adaptive transfer function for deriving the aortic pressure waveform from a peripheral artery pressure waveform
Am J Physiol Heart Circ Physiol, November 1, 2009; 297(5): H1956 - H1963.
[Abstract] [Full Text] [PDF]


Home page
Phil Trans R Soc AHome page
A. Porta, F. Aletti, F. Vallais, and G. Baselli
Multimodal signal processing for the analysis of cardiovascular variability
Phil Trans R Soc A, January 28, 2009; 367(1887): 391 - 409.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C.-J. Thore, J. Stalhand, and M. Karlsson
Toward a noninvasive subject-specific estimation of abdominal aortic pressure
Am J Physiol Heart Circ Physiol, September 1, 2008; 295(3): H1156 - H1164.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.