AJP - Heart Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 293: H3440-H3447, 2007. First published October 12, 2007; doi:10.1152/ajpheart.00707.2007
0363-6135/07 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
293/6/H3440    most recent
00707.2007v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldberger, J. J.
Right arrow Articles by Ng, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldberger, J. J.
Right arrow Articles by Ng, J.

A new method to determine the electrical transfer function of the human thorax

Jeffrey J. Goldberger, Haris Subacius, Indranil Sen-Gupta, David Johnson, Alan H. Kadish, and Jason Ng

Bluhm Cardiovascular Institute, Northwestern University, Northwestern Memorial Hospital, Chicago, Illinois

Submitted 18 June 2007 ; accepted in final form 4 October 2007

Traditional analyses have assumed that cardiac electrical activity is reflected on the surface ECG without distortion as the signal passes through the body tissues. This study aims to explore the frequency dependence of thoracic attenuation of surface-recorded intracardiac electrical activity. Twenty patients (14 men, 55 ± 15 yr of age) undergoing electrophysiological study were enrolled. Rectangular unipolar stimuli were applied from a catheter positioned in the right ventricular apical area and another in the posteroseptal area without contact with the myocardium. An orthogonal Frank-lead surface ECG and a unipolar intracardiac electrogram near the pacing site were recorded. Frequency domain characteristics of the signal-averaged pacing impulses were analyzed. Linear regression analysis showed significant frequency-dependent attenuation in the magnitude transfer functions (R2 = 0.84–0.89, P < 0.0001) and good linear fit for the phase transfer characteristics (R2 = 0.98–1.0, P < 0.0001). Age, physical dimension, and respiratory characteristics had significant effects on the magnitude and phase characteristics of the transfer functions. Application of models of the low- and high-slope transfer functions to signal-averaged ECGs from 33 subjects showed differences in the attenuation of P and T waves relative to the QRS.

electrocardiography; pacing; Fourier analysis



Address for reprint requests and other correspondence: J. J. Goldberger, Northwestern Univ. Feinberg School of Medicine, Division of Cardiac Electrophysiology, 251 East Huron, Feinberg Pavilion, Chicago, IL 60611 (e-mail: j-goldberger{at}northwestern.edu)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.