AJP - Heart BIOPAC complete lab solutions
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 295: H1927-H1934, 2008. First published September 5, 2008; doi:10.1152/ajpheart.00405.2008
0363-6135/08 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
295/5/H1927    most recent
00405.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thijssen, D. H. J.
Right arrow Articles by Green, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thijssen, D. H. J.
Right arrow Articles by Green, D. J.

Heterogeneity in conduit artery function in humans: impact of arterial size

Dick H. J. Thijssen,1,2 Ellen A. Dawson,1 Mark A. Black,1 Maria T. E. Hopman,2 N. Timothy Cable,1 and Daniel J. Green1,3

1Research Institute for Sport and Exercise Science, Liverpool John Moore's University, Liverpool, United Kingdom; 2Department of Physiology, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands; and 3School of Sport Science, Exercise and Health, The University of Western Australia, Crawley, Western Australia

Submitted 17 April 2008 ; accepted in final form 2 September 2008

To determine whether conduit artery size affects functional responses, we compared the magnitude, time course, and eliciting shear rate stimulus for flow-mediated dilation (FMD) in healthy men (n = 20; 31 ± 7 yr). Upper limb (brachial and radial) and lower limb (common and superficial femoral) FMD responses were simultaneously assessed, whereas popliteal responses were measured in the same subjects during a separate visit. Glyceryl trinitrate (GTN)-mediated responses were similarly examined. Edge detection and wall tracking of high-resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, were used to calculate conduit artery diameter, blood flow, and shear rate continuously across the cardiac cycle. Baseline artery size correlated inversely with the FMD response (r = –0.57, P < 0.001). Within-artery comparisons revealed a significant inverse correlation between artery size and FMD% for the radial (r = –0.66, P = 0.001), brachial (r = –0.55, P = 0.01), and popliteal artery (r = –0.48, P = 0.03), but not for the superficial and common femoral artery. Normalization of FMD responses for differences in eliciting shear rate did not abolish the between-artery relationship for artery function and size (r = –0.48, P < 0.001), suggesting that differences between artery function responses were not entirely due to size-related differences in shear rate. This was reinforced by a significant between-artery correlation for GTN responses and baseline artery size (r = –0.74, P < 0.001). In summary, systematic differences exist in vascular function responses of conduit arteries that differ in size. This raises the possibility that differences in artery size within or between individuals may influence functional responses.

flow-mediated dilation; nitroglycerine; arterial diameter; high-resolution ultrasound; Doppler



Address for reprint requests and other correspondence: D. H. J. Thijssen, Research Institute for Sport and Exercise Science, Henry Cotton Campus, Liverpool John Moores Univ., 15-21 Webster St., Liverpool L3 2ET, United Kingdom (e-mail: d.thijssen{at}fysiol.umcn.nl)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
B. J. Wong, G. Simmons, C. Bopp, J. Yeboah, D. P. Casey, C. Austin, H. Tanaka, A. E. DeVan, J. N. Barnes, G. Atkinson, et al.
Commentaries on Viewpoint: Pick your Poiseuille: Normalizing the shear stimulus in studies of flow-mediated dilation
J Appl Physiol, October 1, 2009; 107(4): 1360 - 1365.
[Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. H. J. Thijssen, L. M. Bullens, M. M. van Bemmel, E. A. Dawson, N. Hopkins, T. M. Tinken, M. A. Black, M. T. E. Hopman, N. T. Cable, and D. J. Green
Does arterial shear explain the magnitude of flow-mediated dilation?: a comparison between young and older humans
Am J Physiol Heart Circ Physiol, January 1, 2009; 296(1): H57 - H64.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2008 by the American Physiological Society.