|
|
||||||||
Division of Cardiology, University of Cincinnati Medical Center, Cincinnati, Ohio 45267-0542
| |
ABSTRACT |
|---|
|
|
|---|
We compared
hemodynamics, ventricular function, and force-frequency relationships
in six open-chest and six closed-chest anesthetized mice (FVB/N
strain). Left ventricular (LV) pressure was measured with a 1.8- or
1.4-Fr Millar catheter placed via the right carotid artery and the LV
apex in the closed- and open-chest state, respectively. Pacing was
performed with electrodes placed either directly on atrial appendages
(open chest) or with a 1-Fr bipolar catheter via the jugular vein
(closed chest). Closed-chest animals had greater spontaneous heart rate
(267 ± 106 vs. 147 ± 27 beats/min), LV systolic (81 ± 14 vs. 48 ± 9 mmHg) and diastolic pressures (11.2 ± 4.8 vs. 5.6 ± 2.4 mmHg), and maximal rise
(+dP/dtmax: 6,208 ± 2,519 vs. 3,682 ± 671 mmHg/s) and fall in pressure
development (
dP/dtmax:
6,094 ± 2,386 vs.
3,001 ± 399 mmHg/s). LV
systolic pressure (98 ± 18 vs. 52 ± 11 mmHg),
+dP/dtmax (9,240 ± 2,459 vs. 5,777 ± 2,473 mmHg/s), and
dP/dtmax
(
8,375 ± 2,551 vs.
3,753 ± 1,170 mmHg/s) were
significantly higher when animals were matched at a heart rate of 420 beats/min in closed-chest vs. open-chest animals. Biphasic
force-frequency relationships were seen in all animals, but the
critical heart rate was greater in the closed- than open-chest animals
(432 ± 42 vs. 318 ± 42 beats/min). We conclude that
1) there are significant differences
between invasive indexes of systolic and diastolic function between the
closed- and open-chest preparations,
2) there is a biphasic
force-frequency relationship in the anesthetized mouse, and
3)
dP/dtmax can be used to assess the cardiovascular phenotype.
ventricular function; Starling relationship; transgenic mice
| |
INTRODUCTION |
|---|
|
|
|---|
TRANSGENIC and gene-targeted manipulations of the murine genome are widely employed to understand mechanisms of cardiovascular physiology and disease (4-7, 14, 20, 21). A major limitation of such studies is that the small size of the mouse hampers the ability to characterize the cardiovascular functional phenotype. Although echocardiographic techniques have been used increasingly, a more complete (and complimentary) characterization requires invasive catheter-based approaches. Microsurgical techniques and miniaturization of catheter-transducer systems permit measurement of ventricular pressure; nevertheless, studies are limited largely to measurements of basal and catecholamine-stimulated isovolumic pressure indexes (20, 21). More sophisticated measurements, such as cardiac function curves derived by altering either load [aortic systolic pressure and left ventricular (LV) end-diastolic pressure (EDP)] or heart rate have not been reported. Moreover, both open- and closed-chest anesthetized animals are studied without an understanding of their intrinsic independent effects on measurements of ventricular function. Therefore, we compared hemodynamics and pressure-derived indexes of systolic and diastolic function in the open- versus closed-chest normal mouse.
Recent data in our laboratory indicate that there is a biphasic force-frequency relationship in the sedated primate, and the heart rate at which maximal pressure change over time (dP/dtmax) reaches a maximum (critical heart rate) is a sensitive measure of ventricular systolic function (9). Therefore, the second objective of our study was to determine whether there is a biphasic force-frequency relationship in the anesthetized mouse, and whether it is altered by the type of surgical preparation employed. Finally, we wanted to determine the feasibility of steady-state alterations in LV systolic and diastolic pressure using volume infusions, because this technique has been used extensively in cardiovascular physiological studies in larger mammals.
| |
METHODS |
|---|
|
|
|---|
A total of 16 male and female mice (FVB/N strain) weighing 21.8-35 g were used for these experiments. Animals were studied either in the open-chest or closed-chest state. A dissecting microscope (Olympus) was used for all procedures. A three-lead electrocardiogram was used for timing purposes and to verify atrial capture.
Open-Chest Preparation
Mice (n = 6, 27.8 ± 5.0 g) were anesthetized with a mixture of ketamine (100 mg/kg), xylazine (5 mg/kg), and morphine (2.5 mg/kg) given at 0.25 ml ip and were then taped to the operating table in the supine position. The trachea was exposed and ligated with 6-0 silk. An airway was established by puncturing between the tracheal rings with a 24-gauge Jelco iv catheter; the sheath was advanced 6-7 mm and secured with a 6-0 silk ligature. The animal was ventilated with a tidal volume of 500 µl at 100 cycles/min using a Harvard Respirator (model 863) and room air.The chest was widely opened via a subxiphoid incision and bilateral thoracotomies, and the sternum was reflected and secured with a hemostat. Cautery was used to minimize bleeding. An 1.8-Fr Millar catheter was placed in the LV via the apical dimple and secured with a purse-string suture using 10-0 Dermalon. Custom-made platinum wire (0.127 mm diameter) was insulated with polyethylene tubing except for the unexposed tips, which were attached to the right and left atrial appendages for pacing, and the heart was covered gently with saline-moistened cotton. The jugular vein was cannulated with flame-stretched Nalgene polyethylene tubing (1/8" ID) for intravenous access, and the catheter was secured with a 6-0 silk suture.
Closed-Chest Preparation
Mice (n = 6, 28.9 ± 4.5 g) were anesthetized with a ketamine, xylazine, and morphine mixture as described in Open-Chest Preparation. The trachea was intubated with a 24-gauge Jelco iv catheter, and the animal was allowed to breathe room air spontaneously. The right jugular vein was isolated and ligated cranially with 6-0 silk. Flame-stretched Nalgene polyethylene tubing was advanced into the vein and secured with 6-0 silk. A custom-made 1-Fr bipolar pacemaker (Numed) was positioned in the right atrium via the right internal jugular vein. The right carotid artery was isolated and exposed from its bifurcation caudally; two lengths of 6-0 silk were placed under the vessel. The artery was ligated at its bifurcation, approximately one-half of the length of the isolated region of vessel was longitudinally incised, and a 1.4-Fr Millar high-fidelity catheter was introduced into the vessel. The catheter was advanced past the distal tie in a single, quick continuous movement into the left ventricle and secured with 6-0 silk.Data Analysis
The micromanometer was electronically calibrated in vitro by submersing the tip of the catheter in warmed saline with the reference zero level taken at midchest. The analog LV dP/dt signal was obtained online by electronic differentiation of the high-fidelity LV pressure signal. Analog signals for high-fidelity LV pressure, LV dP/dt, and the electrocardiogram were recorded online on a Gould WindowGraf four-channel recorder (Gould) at 25 and 100 mm/s paper speed. A constant infusion minipump (Baxter Autosyringe AS20A) was used for volume infusion.Experimental Protocols
Incremental pacing. A Grass stimulator (model S88) was set at 3-4 V, 2 m/s pulse-width duration, and the desired frequency. After hemodynamic stability was ensured and baseline data were recorded, pacing was initiated just above the intrinsic heart rate to avoid competing rhythms and was increased at 12 beats/min increments until the LV dP/dtmax was visually decreased or until atrioventricular block unresponsive to 0.04-0.08 ng/g atropine supervened. The animals were allowed to recover between protocols.After hemodynamics returned to baseline, LV pressure was increased in open-chest mice (see Volume infusion) by incremental steady-state infusion of Hespan (6% hetastarch in 9% NaCl).
Volume infusion. Open-chest animals (n = 8) were paced at a constant heart rate of 300 beats/min. Hespan was used to raise EDP and infused at a rate of 10 ml/h using a microinfusion pump, with "steady-state" data taken at 0.1-ml increments until ~1.4 ml were infused.
Experiments were conducted in accordance with institutional guidelines and the Guide for the Care and Use of Laboratory Animals put forth by the United States Department of Health and Human Services, NIH publication No. 86-23. The experimental protocol was approved by the Institutional Animal Care and Use Committee at the University of Cincinnati.
Statistics
Data from open- and closed-chest animals were compared with unpaired t-tests. Analysis of variance was used to test means within groups for the pacing and volume infusion studies, and Bonferroni-corrected t-tests were used to identify differences. Unless otherwise stated, data are expressed as means ± SD. A value of P < 0.05 was considered statistically significant.| |
RESULTS |
|---|
|
|
|---|
Hemodynamics in the open- and closed-chest preparations at the
intrinsic heart rate are shown in Table 1.
The intrinsic heart rate, LV systolic and EDP, and increased
(+dP/dtmax) and
decreased dP/dtmax
(
dP/dtmax)
were significantly greater in the closed-chest than open-chest
animals. At a matched heart rate of 300 beats/min, the LV
systolic pressure, LVEDP, and
dP/dtmax
were significantly greater in closed-chest than open-chest mice; the
greater +dP/dtmax in closed- than open-chest animals did not achieve statistical significance (Table 2). In contrast, at a
matched heart rate of 420 beats/min, the LV systolic pressure,
+dP/dtmax, and
dP/dtmax were significantly greater in the closed-chest than open-chest animals
(Table 2). Although the LVEDP was greater in the closed-chest preparations, this difference was not statistically significant.
|
|
The effects of incremental pacing on LV dP/dtmax (biphasic force-frequency response) in closed- and open-chest animals are shown in Fig. 1. Incremental atrial pacing resulted in significant increases in dP/dtmax in both open- and closed-chest animals. However, compared with the response in open-chest animals, the force-frequency curve in closed-chest animals was shifted upward and to the right, resulting in a delayed descending limb of the force-frequency relationship. Thus the critical heart rate for dP/dt was significantly greater in the closed- than open-chest preparation (432 ± 42 vs. 318 ± 42 beats/min, P < 0.05).
|
In both open- and closed-chest animals, incremental pacing produced significant increases in LV systolic pressure and decreases in LVEDP (Fig. 2). As pacing progressed beyond the critical heart rate, both LV systolic pressure and EDP decreased. Moreover, in the closed-chest state there was an upward and rightward shift of the LV pressure-heart rate relationship compared with the open-chest state.
|
The effect of Hespan infusion is shown in Fig. 3. Representative hemodynamic records are shown in Fig. 3A. For the entire group, LV dP/dtmax increased with LVEDP until an EDP of ~15 mmHg was reached and was significantly greater at high versus low LVEDP (Fig. 3B); additional increases in LVEDP could not be consistently achieved. In contrast, saline was ineffective in raising LVEDP in pilot studies (data not shown). LV systolic pressure increased significantly with volume infusion (Fig. 3C); it should be recognized that the LV systolic pressure at a paced heart rate of 300 beats/min (near the critical HR) was greater than that observed at the intrinsic heart rate and the paced rate of 420 beats/min.
|
| |
DISCUSSION |
|---|
|
|
|---|
The principal findings of this study are that in the normal mouse left ventricle 1) there is a biphasic force-frequency relationship in both the open- and closed-chest anesthetized state, 2) hemodynamics and force-frequency relationships obtained in the closed-chest state are significantly different (i.e., less depressed) than those observed in the open-chest preparation, and 3) steady-state alterations in LVEDP (and presumably LV end-diastolic volume) can be obtained with Hespan infusion.
Our data indicate that LV performance measurements vary depending on the particular state in which they are acquired, and emphasize the need for appropriate controls. The anesthetic we employed includes morphine, which may be responsible for the "nonphysiological" heart rates and systemic blood pressures, which were lower than those reported by other investigators (12, 15, 19). However, at the critical heart rate, the LV systolic pressure in the open-chest mice was similar to that previously reported (15, 19). Surgical trauma and the potential blood loss were greater in the open- than the closed-chest preparation; thus, we cannot exclude the possibility that the low dP/dtmax and the altered force-frequency relationships in open-chest mice were influenced by diastolic hypoperfusion and myocardial ischemia. However, in the current study, LVEDP decreased and LV systolic pressure increased as heart rate increased from the intrinsic to the critical heart rate in both groups of animals; these results suggest that myocardial ischemia is unlikely to be primarily responsible for the differences we observed. Irrespective of the cause(s) of the different hemodynamics, our findings argue strongly for the use of an experimental preparation appropriate for the anticipated cardiovascular phenotype. For example, a phenotype characterized by loss of function may be easier to identify in the context of a preparation with increased function (such as the closed chest). In contrast, a phenotype characterized by gain of function may be easier to identify in the context of a model with decreased function (such as the open chest).
Incremental pacing has been used to assess myocardial contractility in isolated muscle preparations and has recently been described to assess LV function. A biphasic force-frequency relationship with ascending and descending limbs has been demonstrated in both isolated muscle strips (3, 16) and the sedated baboon (9). The effects of increased heart rate are greater in the anesthetized than conscious animal preparation; indeed, both the 44 and 40% increases in dP/dtmax we observed in the open and closed chest, respectively, are greater than the 26% increase in sedated baboons (9) and the 28% increase reported in conscious dogs (2). The biphasic force-frequency relationship we observed differs from a report in the isolated blood-perfused mouse heart (1); in that study, incremental pacing from 3 to 10 Hz produced a negative developed pressure-heart rate relationship. However, our results are consistent with a recent report that demonstrated biphasic force-frequency relationships using a sinus node-slowing pharmacological agent and atrial pacing in the open-chest mouse and the recovery from anesthesia in the closed-chest mouse (17). Interestingly, dP/dtmax values at baseline and in response to changes in heart rate that were observed in both of their preparations are similar to our findings; however, it should be noted that a descending limb of the force-frequency was not seen in unpaced animals recovering from anesthesia (17).
The potential causes of the descending force-frequency limb in our
preparations include 1) qualitative
alterations in the contractile and calcium-cycling proteins that limit
the ability of the myocyte to release, interact with, and resequester
calcium; 2) arterial hypotension
with resultant myocardial ischemia;
3) tachycardia-induced reduction of
LV preload (LVEDP or volume); and 4)
rapid-pacing-induced atrioventricular conduction delay causing a poorly
timed atrial contraction. Previous studies have shown that both chronic
thyroid hormone administration (9) and acute
-adrenergic stimulation
(17), conditions that alter calcium homeostasis, delay the descending
limb of the force-frequency relationship. Similar to our earlier
results (9), it is likely that the decrease in preload produced by
increased heart rates underestimated the magnitude of the
force-frequency effect; moreover, the continued fall of LVEDP beyond
the critical heart rate suggests that myocardial ischemia does not
account for the descending limb. Finally, although atrioventricular
conduction was not rigorously assessed in this study, atrioventricular
nodal Wenckebach occurred at, or shortly after, the critical heart rate
in the majority of animals (data not shown).
An important finding of our study is that dP/dtmax increases with a volume-induced increase in LVEDP in the mouse. A linear relationship between LV end-diastolic volume and dP/dtmax is predicted by the time-varying elastance model (11), although earlier studies employing LVEDP as a measure of LV preload yielded similar results (13, 24). It should be emphasized that we cannot extrapolate to a LVEDP >15 mmHg, where curvilinearity of the LV pressure-volume relationship might alter the EDP-dP/dtmax relationship. Nevertheless, these data demonstrate the feasibility of altering load in the intact mouse and confirm that dP/dtmax is preload dependent in the mouse as with other species. Volume and pressure loading can be used to assess cardiovascular function and cardiac reserve and combined with measures of ventricular size (for example with either miniaturized sonomicrometers in the open-chest or echocardiography in the closed-chest preparation) suggest that generation of pressure-dimension indexes of systolic and diastolic function are possible.
An important limitation of these studies is that they were performed in the anesthetized animal. Thus both of these preparations are confounded by the effects of general anesthesia. Although ketamine is a central sympathetic stimulant, most general anesthetics induce vasodilation and hypotension when given in sufficient doses. In addition, all anesthetics cause myocardial depression (18), affect cardiac control mechanisms (e.g., the Frank-Starling mechanism, the Anrep effect, and the treppe or Bowditch effect), and influence the mechanisms involved in the baroreceptor response and reflex control. It should be recognized that many of these control mechanisms are not considered to play a significant role in conscious animals at a physiological heart rate (23). Another potential limitation relates to the low LV systolic blood pressures (especially at the intrinsic heart rate in the open-chest animals), the absence of aortic diastolic pressures, and the resultant inability to be certain that LV dP/dtmax occurred during isovolumic systole at these low pressures. Finally, it is assumed that the trauma of surgery and anesthesia does not alter the cardiovascular response to a specific experimental perturbation. Nevertheless, conscious data in the mouse should be interpreted with a healthy degree of caution; unless the experimental animals are acclimatized by a period of training, the associated stress leads to high circulating catecholamines and may alter the chronotropic and inotropic state of the preparation. In this regard, telemetered systems should prove useful in conscious studies (22).
Despite these limitations we have shown that a variety of techniques used to evaluate cardiovascular function in larger animals can be applied to evaluate the phenotypic expression and complex physiological traits in the intact transgenic or gene-targeted mouse. Insofar as all animal models have difficulties and limitations, understanding the influence of the preparation will minimize interpretative errors and facilitate recognition of true physiological or pathological differences.
| |
ACKNOWLEDGEMENTS |
|---|
The authors are grateful to Norma Burns for expert secretarial assistance and Dr. Doug Magorien for technical assistance.
| |
FOOTNOTES |
|---|
This study was supported in part by National Heart, Lung, and Blood Institute Specialized Center of Research in Heart Failure P-50-HL-52318.
Address for reprint requests: B. D. Hoit, Division of Cardiology, Univ. of Cincinnati, PO Box 670542, Cincinnati, OH 45267-0542.
Received 14 March 1997; accepted in final form 25 July 1997.
| |
REFERENCES |
|---|
|
|
|---|
1.
Brooks, W. W.,
and
C. S. Apstein.
Effect of treppe on isovolumic function in the isolated blood-perfused mouse heart.
J. Mol. Cell Cardiol.
28:
1817-1822,
1996[Medline].
2.
Freeman, G. L.,
W. C. Little,
and
R. A. O'Rourke.
Influence of heart rate on left ventricular performance in conscious dogs.
Circ. Res.
61:
455-464,
1987
3.
Hasenfuss, G.,
H. Reinecke,
R. Studer,
M. Meyer,
B. Pieske,
J. Holtz,
C. Holubarsch,
H. Posival,
H. Just,
and
H. Drexler.
Relation between myocardial function and expression of sarcoplasmic reticulum Ca2+ ATPase in failing and nonfailing human myocardium.
Circ. Res.
75:
434-442,
1994
4.
Hoit, B. D.,
S. F. Khoury,
E. G. Kranias,
N. Ball,
and
R. A. Walsh.
In vivo echocardiographic detection of enhanced left ventricular function in gene-targeted mice with phospholamban deficiency.
Circ. Res.
77:
632-637,
1995
5.
Iwase, M.,
S. P. Bishop,
M. Uechi,
D. E. Vatner,
R. P. Shannon,
K. Kudej,
D. C. Wight,
T. E. Wagner,
Y. Ishikawa,
C. J. Homcy,
and
S. F. Vatner.
Adverse effects of chronic endogenous sympathetic drive induced by cardiac Gsa overexpression.
Circ. Res.
78:
517-524,
1996
6.
Kadambi, V. J.,
S. Ponniah,
J. M. Harrer,
B. D. Hoit,
G. W. Dorn II,
R. A. Walsh,
and
E. G. Kranias.
Cardiac-specific overexpression of phospholamban alters calcium kinetics and resultant cardiomyocyte mechanics in transgenic mice.
J. Clin. Invest.
97:
533-539,
1996[Medline].
7.
Kaplan, M. L.,
Y. Cheslow,
K. Vikstrom,
A. Mahlhotra,
G. L. Geenen,
A. Nakouzi,
L. A. Leinwand,
and
P. M. Buttrick.
Cardiac adaptations to chronic exercise in mice.
Am. J. Physiol.
267 (Heart Circ. Physiol. 36):
H1167-H1173,
1994
8.
Kass, D. A.,
W. L. Maughman,
Z. M. Guo,
A. Kono,
K. Sunagawa,
and
K. Sagawa.
Comparative influence of load versus inotropic states on indexes of ventricular contractility: experimental and theoretical analysis based on pressure-volume relationships.
Circulation
76:
1422-1436,
1987
9.
Khoury, S. F.,
B. D. Hoit,
V. Dave,
C. M. Pawloski-Dahm,
Y. Shao,
M. Gabel,
M. Periasamy,
and
R. A. Walsh.
Effects of thyroid hormone on left ventricular performance and regulation of contractile and Ca2+-cycling proteins in the baboon. Implications for the force-frequency and relaxation-frequency relationships.
Circ. Res.
79:
727-735,
1996
10.
Lee, J.,
T. Tajimi,
T. F. Widmann,
and
J. Ross, Jr.
Application of end-systolic pressure-volume and pressure-wall thickness relations in conscious dogs.
J. Am. Coll. Cardiol.
9:
136-146,
1987[Abstract].
11.
Little, W. C.
The left ventricular dP/dtmax-end-diastolic volume relation in closed-chest dogs.
Circ. Res.
56:
808-815,
1985
12.
Lorenz, J. N.,
and
J. Robbins.
Measurement of intraventricular pressure and cardiac performance in the intact closed-chest anesthetized mouse.
Am. J. Physiol.
272 (Heart Circ. Physiol. 41):
H1137-H1146,
1997
13.
Mahler, F.,
J. Ross, Jr.,
R. A. O'Rourke,
and
J. W. Covell.
Effects of changes in preload, afterload and inotropic state on ejection and isovolumic phase measures of contractility in the conscious dog.
Am. J. Cardiol.
35:
626-634,
1975[Medline].
14.
Michael, L. H.,
M. L. Entman,
C. J. Hartley,
K. A. Youker,
J. Zhu,
S. R. Hall,
H. K. Hawkins,
K. Berens,
and
C. M. Ballantyne.
Myocardial ischemia and reperfusion: a murine model.
Am. J. Physiol.
269 (Heart Circ. Physiol. 38):
H2147-H2154,
1995
15.
Milano, C. A.,
L. F. Allen,
H. A. Rockman,
P. C. Dolber,
T. R. McMinn,
K. R. Chien,
T. D. Johnson,
R. A. Bond,
and
R. J. Lefkowitz.
Enhanced myocardial function in transgenic mice overexpressing the
2-adrenergic receptor.
Science
264:
582-586,
1994
16.
Mulieri, L. A.,
G. Hasenfuss,
B. Leavitt,
P. D. Allen,
and
N. R. Alpert.
Altered myocardium force-frequency relation in human heart failure.
Circulation
85:
1743-1750,
1992
17.
Palakodeti, V.,
S. Oh,
B. H. Oh,
L. Mao,
M. Hongo,
and
J. Ross, Jr.
The force-frequency effect is a powerful determinant of myocardial contractility in the mouse.
Am. J. Physiol.
273 (Heart Circ. Physiol. 42):
H1283-H1290,
1997
18.
Price, H. L.,
and
S. T. Ohnishi.
Effects of anesthetics on the heart.
Federation Proc.
39:
1575-1579,
1980[Medline].
19.
Rockman, H. A.,
D.-J. Choi,
N. U. Rahman,
S. A. Akhter,
R. J. Lefkowitz,
and
W. J. Koch.
Receptor-specific in vivo desensitization by the G protein-coupled receptor kinase-5 in transgenic mice.
Proc. Natl. Acad. Sci.
93:
9954-9959,
1996
20.
Rockman, H. A.,
R. A. Hamilton,
L. R. Jones,
C. A. Milano,
L. Mao,
and
R. J. Lefkowitz.
Enhanced myocardial relaxation in vivo in transgenic mice overexpressing the
2-adrenergic receptor is associated with reduced phospholamban protein.
J. Clin. Invest.
97:
1618-1623,
1996[Medline].
21.
Turki, J.,
J. N. Lorenz,
S. A. Green,
E. T. Donnelly,
M. Jacinto,
and
S. B. Liggett.
Myocardial signaling defects and impaired cardiac function of a human
2-adrenergic receptor polymorphism expressed in transgenic mice.
Proc. Natl. Acad. Sci.
93:
10483-10488,
1996
22.
Uechi, M.,
M. Osaka,
J. Mokhtar,
N. Sato,
K. Asai,
T. E. Wagner,
Y. Ishikawa,
D. E. Vatner,
R. J. Cohen,
C. J. Homcy,
and
S. F. Vatner.
Autonomic regulation of heart rate variability in transgenic mice with overexpression of cardiac Gs-alpha (Abstract).
Circulation
94:
I490,
1996.
23.
Vatner, S. F.,
and
E. Braunwald.
Cardiovascular control mechanisms in the conscious state.
N. Eng. J. Med.
293:
970-976,
1975[Medline].
24.
Wallace, A. G.,
S. Skinner,
and
H. J. Mitchell.
Hemodynamic determinants of the maximal rate of rise of left ventricular pressure.
Am. J. Physiol.
205:
30-36,
1963.
This article has been cited by other articles:
![]() |
K. M. Shioura, D. L. Geenen, and P. H. Goldspink Assessment of cardiac function with the pressure-volume conductance system following myocardial infarction in mice Am J Physiol Heart Circ Physiol, November 1, 2007; 293(5): H2870 - H2877. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Uemura, T. Kawada, M. Sugimachi, C. Zheng, K. Kashihara, T. Sato, and K. Sunagawa A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats Am J Physiol Heart Circ Physiol, December 1, 2004; 287(6): H2906 - H2913. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Ishizaka, R. E. Sievers, B.-Q. Zhu, M. C. Rodrigo, S. Joho, E. Foster, P. C. Simpson, and W. Grossman New technique for measurement of left ventricular pressure in conscious mice Am J Physiol Heart Circ Physiol, March 1, 2004; 286(3): H1208 - H1215. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Tarnavski, J. R. McMullen, M. Schinke, Q. Nie, S. Kong, and S. Izumo Mouse cardiac surgery: comprehensive techniques for the generation of mouse models of human diseases and their application for genomic studies Physiol Genomics, February 13, 2004; 16(3): 349 - 360. [Abstract] [Full Text] [PDF] |
||||
![]() |
Q. Wang, H. R. Brunner, and M. Burnier Determination of cardiac contractility in awake unsedated mice with a fluid-filled catheter Am J Physiol Heart Circ Physiol, February 1, 2004; 286(2): H806 - H814. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. R. Woldbaek, T. A. Stromme, J. B. Sande, G. Christensen, T. Tonnessen, and A. Ilebekk Evaluation of a new fiber-optic pressure recording system for cardiovascular measurements in mice Am J Physiol Heart Circ Physiol, November 1, 2003; 285(5): H2233 - H2239. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Collins, C. E. Korcarz, and R. M. Lang Use of echocardiography for the phenotypic assessment of genetically altered mice Physiol Genomics, May 13, 2003; 13(3): 227 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nemoto, G. DeFreitas, D. L. Mann, and B. A. Carabello Effects of changes in left ventricular contractility on indexes of contractility in mice Am J Physiol Heart Circ Physiol, December 1, 2002; 283(6): H2504 - H2510. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. R. Cross, E. Murphy, R. G. Black, J. Auchampach, and C. Steenbergen Overexpression of A3 adenosine receptors decreases heart rate, preserves energetics, and protects ischemic hearts Am J Physiol Heart Circ Physiol, October 1, 2002; 283(4): H1562 - H1568. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Nemoto, J. G. Vallejo, P. Knuefermann, A. Misra, G. Defreitas, B. A. Carabello, and D. L. Mann Escherichia coli LPS-induced LV dysfunction: role of toll-like receptor-4 in the adult heart Am J Physiol Heart Circ Physiol, June 1, 2002; 282(6): H2316 - H2323. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |