|
|
||||||||
1 Department of Medical Physics, Cardiovascular Research Institute Amsterdam, Academic Medical Center, University of Amsterdam, 1100 DE Amsterdam, The Netherlands; and 2 Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama 701-0192, Japan
| |
ABSTRACT |
|---|
|
|
|---|
The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and subepicardial (n = 12) arterioles (<120 µm) after stepwise decreases in coronary arterial pressure from 100 to 70, 50, and 30 mmHg in vivo in dogs (n = 9). Pressure steps were performed with and without stenosis on the perfusion line. Maximal arteriolar diameter during the cardiac cycle was determined and normalized to its value at 100 mmHg. The initial decrease in diameter during reductions in pressure was significantly larger at the subendocardium. Diameters of subendocardial and subepicardial arterioles were similar 10-15 s after the decrease in pressure without stenosis. However, stenosis decreased the dilatory response of the subendocardial arterioles significantly. This decreased dilatory response was also evidenced by a lower coronary inflow at similar average pressure in the presence of a stenosis. Inhibition of nitric oxide production with NG-monomethyl-L-arginine abrogated the effect of the stenosis on flow. We conclude that the decrease in pressure caused by a stenosis in vivo results in a larger decrease in diameter of the subendocardial arterioles than in the subepicardial arterioles, and furthermore stenosis selectively decreases the dilatory response of subendocardial arterioles. These two findings expand our understanding of subendocardial vulnerability to ischemia.
autoregulation; coronary microcirculation; ischemia
| |
INTRODUCTION |
|---|
|
|
|---|
IF CORONARY BLOOD FLOW is limited due to a stenosis in one of the coronary arteries, myocardial ischemia first develops in the subendocardium. Flow measurements with microspheres have shown that with progressive coronary stenosis, flow to the subendocardium decreases earlier and to a larger extent than flow to the subepicardium (3). It has been well established that extravascular factors such as myocardial contraction limit subendocardial perfusion. However, there also may be differences in dilatory capacity between the subendocardium and the subepicardium. Direct observation of subepicardial arterioles in the presence of a stenosis revealed that these vessels no longer dilated when coronary pressure dropped to ~30-40 mmHg (5, 12). We hypothesized that the dilatory capacity at the subendocardium would disappear at higher coronary perfusion pressures. The purpose of this study is therefore to compare the dilatory responses of subendocardial and subepicardial arterioles to decreased coronary perfusion induced by a stenosis.
A coronary stenosis has two different hemodynamic consequences: decreased mean coronary perfusion pressure and decreased coronary flow pulsations (10, 11). Both the decrease in coronary perfusion pressure and the decrease in pulsatile flow may decrease myocardial perfusion or alter its distribution. Our coronary perfusion system (17) enables us to decrease pressure while keeping pulsatile flow intact and minimize flow pulsations while maintaining pressure. With the use of a needle-probe charge-coupled device (CCD) camera, we directly observed the response of subendocardial and subepicardial arterioles to decreases in coronary perfusion pressure with and without pulsatile coronary flow.
| |
MATERIALS AND METHODS |
|---|
|
|
|---|
All experiments were done in accordance with the guidelines on animal experiments of our institutions. Thirteen mongrel dogs were sedated with an injection of ketamine (10 mg/kg im) and were then given an injection of pentobarbital sodium (25 mg/kg iv) for anesthesia. Depth of anesthesia was monitored by checking reflexes, and additional anesthesia was given when necessary. Dogs were ventilated (after tracheal intubation) with a mixture of room air and oxygen using a jet ventilator. Blood gasses and pH were measured regularly, and oxygen and CO2 were kept within physiological limits by adaptation of the ventilation (pH = 7.35-7.45, PCO2 = 25-40 mmHg, PO2 > 70 mmHg). When necessary, sodium bicarbonate was given to avoid acidosis.
The left jugular vein was dissected free and a thin polyethylene catheter was inserted for administration of drugs. The left carotid artery was dissected free and an 8-Fr pigtail double-lumen manometer catheter (Mikro-Tip SPC-784A catheter transducer, Millar Instruments) was inserted and advanced until one of its sites of measurement was in the left ventricle while the second remained in the ascending aorta.
The thorax was opened through a medial sternotomy and a thoracotomy between the third and the fourth ribs. The pericardium was opened and the heart was suspended in a pericardial cradle. Two pacing wires were sewn onto the right atrial appendage and connected to a pacer. The sinus node was destroyed by injection of 40% formaldehyde and the heart was paced at a constant heart rate of 100-120 beats/min.
Application of System for Controlled Perfusion of Coronary Arteries
To manipulate coronary arterial pressure and its pulsations, the heart was perfused with blood from the left femoral artery by means of a perfusion system similar to the one described by Spaan (16). To avoid coagulation, heparin was administered (initial dose 3 ml, 5,000 IU/ml iv, followed by continuous administration). An in-line flow probe (Transonic 4-Fr, connected to a T206 Transonic flowmeter) just proximal to the Gregg cannula in the left main coronary artery was used to measure phasic coronary blood flow. Coronary perfusion pressure was measured either with a thin fluid-filled catheter at the cannula tip or a fluid-filled 24-gauge catheter in the first diagonal branch of the left anterior descending coronary artery.Application of Videomicroscope
Subendocardial and subepicardial microvessels were visualized using a needle-probe videomicroscope coupled to a CCD camera as previously described (19). The needle probe was enclosed in a Silastic 14-Fr double-lumen sheath. A doughnut-shaped balloon on the tip of the sheath prevents direct compression of the microvessels by the needle tip as was evidenced by diameter pulsations of the vessels during the entire protocol and prompt responses of the vessels to a decrease in coronary perfusion pressure. Blood between the needle tip and the vessels can be flushed away by injection of saline through a small channel of the sheath.Images on the CCD camera were monitored and recorded on videotape every 33 ms. The spatial resolution of this system is 2.5-5 µm for ×200 magnification. The maximal depth of field is ~250 µm.
For observation of subepicardial microvessels, the needle probe with inflated balloon was placed gently on the epicardial surface and moved slowly to find microvessels of appropriate size (40-120 µm). For observation of subendocardial microvessels, the needle probe was inserted through an incision in the left atrial appendage via the mitral valve into the left ventricle. The balloon was then inflated and the needle probe was placed gently on the endocardial surface (septum between anterior and posterior papillary muscle) and moved slowly until a microvessel was found. When necessary the blood between the probe and the endocardial surface was flushed away with saline. When a clear image was obtained either of a subendocardial or a subepicardial vessel, an operator manually maintained the probe in the same position by monitoring the image. The vascular image was then stored on the VCR. Arterioles were distinguished from veins by intracoronary injection of the dye indocyanin green with the camera in color mode. The dye appeared first in the arterioles and then in the venules.
Protocol
While subepicardial [n = 12, diameter 80.3 ± 5.0 µm (mean ± SE)] or subendocardial (n = 10, diameter 64.5 ± 5.9 µm) arterioles were observed by the videomicroscope, perfusion pressure was lowered stepwise from 100 mmHg (control) to either 70, 50, or 30 mmHg and kept at this level for 20-30 s before being increased back to control level. A screw clamp which caused a pressure drop of ~100 mmHg was applied on the perfusion line to increase pressure pulsations and to decrease flow pulsations which is a pattern essentially similar to a pathological stenosis in the coronary arteries (11). Pressure proximal to the clamp was increased to maintain an average distal (perfusion) pressure of 100 mmHg and then pressure steps were performed as described above. Pressure steps without stenosis were performed in 8 out of 10 subendocardial arterioles and in 10 out of 12 subepicardial arterioles. Pressure steps in the presence of a stenosis were performed for all subepicardial arterioles and in 9 out of 10 subendocardial arterioles.Left ventricular pressure, aortic pressure, coronary perfusion pressure, and coronary blood flow were measured during the interventions, digitized at a rate of 80 Hz, and stored on a personal computer.
Adenosine and NG-Monomethyl-L-Arginine Experiments
At the end of the diameter protocols, adenosine was administered in four experiments and NG-monomethyl-L-arginine (L-NMMA) was given in four different experiments. Under these conditions the pressure-step protocols were repeated to establish pressure and flow relations similar to those measured during the diameter-change protocols. No data on diameters are available from these experiments.Data Analysis
At the end of the experiment, the time-sequential images were transferred from videotape to a personal computer. Vascular diameter was determined from the digitized images by manual border tracing. Diameters of the vessels were determined throughout the cardiac cycle from 2.5 s before until 2.5 s after the pressure step downward and during another 3 s after allowing 10-15 s for vasodilation at low pressure. In this period of time, flow reached a new steady state. The diameter was measured in approximately one out of every two images or every image if diameter changed abruptly, which yielded a time resolution of either 33 or 66 ms. During each period of measurement, minimal, maximal, and end diastolic (just before the R wave of the electrocardiogram) diameter were determined for 3-6 consecutive beats. The averages of these measurements were used. All diameters were normalized to their average value at 100 mmHg arterial pressure in control to compare subendocardial and subepicardial arterioles. Both maximal and end-diastolic diameters were used for comparison. The effect of a stenosis was investigated by comparing the maximal diameters at the same mean coronary arterial pressure.Statistics
Data are given as means ± SE. The effects of pressure and stenosis on diameter were determined using ANOVA and paired t-tests. The differences between subendocardial and subepicardial arterioles were tested using unpaired t-tests.| |
RESULTS |
|---|
|
|
|---|
Hemodynamics
Typical examples of a pressure step from 100 to 50 mmHg with and without stenosis are shown in Fig. 1. Note that both left ventricular pressure and its derivative remain rather constant during the periods of reduced pressure. Without stenosis, mean perfusion pressure was constant after the pressure step, and flow increased due to vasodilation after the initial drop. In the presence of a stenosis however, vasodilation resulted in a slight increase in flow and a decrease in perfusion pressure, which is in accordance with earlier studies from our laboratory (7).
|
The application of the needle probe for measurement of subendocardial
arterioles did not result in a decrease in left ventricular pressure,
indicating that the pump function of the heart was not affected (see
the hemodynamic variables in Table 1).
|
Furthermore, the increase in flow during reactive hyperemia after a 15-s occlusion was 3.1 ± 0.2-fold, indicating that autoregulation was present in our preparation.
Changes in Arteriolar Diameter
In Fig. 2, the diameter changes of a subepicardial arteriole during stepwise changes in pressure without stenosis (left) and with stenosis (right) are shown. The change in diameter after a pressure step from 100 to 70 mmHg (Fig. 2A) was small. The diameter 10 s after the pressure step was larger than the diameter immediately after the pressure step both in the presence and absence of a stenosis. The diameter change of the same arteriole after a pressure step from 100 to 30 mmHg is also depicted (Fig. 2B). Maximal diameter decreased immediately after the pressure step but increased between 2 and 10 s after the pressure step. The changes in maximal diameter after the pressure steps were similar in the presence and absence of a stenosis.
|
Phasic Patterns
At high pressure (100 and 70 mmHg), diameter of the subepicardial arterioles increased during systole and decreased in the subsequent diastole (Fig. 2A). At 30 mmHg, the pattern of the diameter variation during cardiac contraction was quite different especially without stenosis (Fig. 2B, left). Diameter decreased sharply at the onset of systole in three of the vessels, increased during the plateau phase of left ventricular pressure, and decreased slowly during diastole. In the remaining vessels, diameter increased gradually during systole at low pressures as well. The stenosis reduced the diameter pulsations at all pressures.Figure 3 depicts the diameter change of a
subendocardial arteriole. In response to a pressure step from 100 to 70 mmHg (Fig. 3A), maximal diameter first decreased and then
increased during the next 10 s especially in the absence of a
stenosis on the perfusion line (left). Figure 3B
again shows the diameter responses to a pressure step from 100 to 30 mmHg with and without a stenosis. The decrease in diameter was larger
after the pressure step to 30 mmHg than after the pressure step to 70 mmHg. Maximal diameter 10-15 s after the pressure step was larger
than immediately after the pressure step.
|
The diameter of the subendocardial arteriole decreases during systole at all pressures. These diameter pulsations are slightly less in the presence of a stenosis.
Effects of Pressure
Figure 4 shows the average relation between coronary perfusion pressure and beat-maximal diameter normalized to maximal diameter at 100 mmHg. Normalized diameters of the subendocardial arterioles immediately after the pressure steps were significantly smaller than those of the subepicardial arterioles at the same pressures both with (Fig. 4B) and without (Fig. 4A) stenosis. The diameters of the subendocardial and subepicardial arterioles were similar 15 s after the step without stenosis. Hence the diameter of the subendocardial arterioles initially decreased more than that of the subepicardial arterioles, but the subendocardial arterioles subsequently dilated more resulting in similar normalized diameters 15 s after the pressure change. With stenosis the diameter of the subendocardial arterioles 15 s after the decrease in pressure remained smaller than that of the subepicardial arterioles at 70 mmHg but not at 50 mmHg. Autoregulation was present because flow 15 s after the pressure step was not significantly different between 70 and 100 mmHg but decreased with pressure at 50 and 30 mmHg (Fig. 5C).
|
|
Influence of a Stenosis
The effect of the stenosis on maximal diameter and total coronary blood flow is shown in Fig. 5. Two seconds after a reduction in pressure the relations between pressure and diameter for both subendocardial (Fig. 5A) and subepicardial (Fig. 5B) arterioles and the relation between pressure and flow (Fig. 5C) were not influenced by the stenosis. However, 15 s after the reduction in pressure, both total coronary blood flow and diameter of the subendocardial arterioles were significantly smaller in the presence of a stenosis at matched average pressures (49 ± 3 and 49 ± 4 mmHg, stenosis absent and present, respectively), whereas there was no significant difference at higher pressure.The stenosis had no effect on the pressure-flow relations at maximal
dilation as is shown in four experiments with adenosine (Fig.
6A). Furthermore, the effect
of the stenosis on the pressure-flow relations was abrogated in four
experiments with L-NMMA (Fig. 6B).
|
| |
DISCUSSION |
|---|
|
|
|---|
Summary of Findings
A coronary stenosis has two major hemodynamic effects on myocardial perfusion: a drop in mean perfusion pressure and a decrease in flow pulsatility. We separated these two effects by performing stepwise changes in coronary arterial pressure in the presence and absence of a stenosis. The effects of these pressure steps on mean arterial flow and diameters of subendocardial and subepicardial arterioles were studied. Initially, the maximal diameter of the subendocardial arterioles decreased more in response to a decrease in coronary arterial pressure than the maximal diameter of the subepicardial arterioles both in the presence and absence of a stenosis. The normalized maximal diameter of the subendocardial arterioles 10-15 s after the pressure step was similar to that of the subepicardial arterioles in the absence of a stenosis. However, the stenosis affected dilation of the subendocardial arterioles, whereas the dilation of the subepicardial arterioles remained unchanged after 10-15 s of low pressure. Flow to the myocardium at similar distal perfusion pressure was lower in the presence of a stenosis, which is in agreement with the reduced diameters in the subendocardium.Methodological Limitations
The vessels found in the subendocardium limited our range of vessel diameters to 40-120 µm. From the literature, the dilatory responses are expected to be largest in this diameter range (13, 18).We have quantified the responses of resistance vessels by maximal diameter during the heartbeat. The initial decrease in diameter is passive and due to a decrease in intravascular pressure because the initial measurements were taken 2 s after a change in pressure that is too fast for changes in tone to occur. This initial decrease in diameter needs to be overcome by vasodilation. We therefore defined vasodilation as the change in diameter between 2 and 15 s after the pressure step. However, full description of a vasodilatory response would require knowledge about local intravascular pressure. An increase in diameter at constant intravascular and extravascular pressures would be vasodilation comparable to that in an isolated vessel experiment. However, intravascular pressure of a resistance vessel somewhere in the arterial tree depends not only on the pressure at the entrance and outlet of the arterial tree but also on the balance of proximal and distal resistances. Dilation is larger in distal vessels than in more proximal vessels. Therefore, it is possible that the intravascular pressure of the vessels we measured actually decreased and that we underestimated the decrease in tone. Unfortunately, no measurements of intravascular pressure in subendocardial arterioles of a beating autoregulating heart are available. In the nonbeating heart without vascular tone, it was shown that pressure in subendocardial arterioles is lower than pressure in subepicardial arterioles of the same size at perfusion pressures ranging from 40 to 100 mmHg (4).
By comparing responses in a normalized and standardized manner, we have tried to minimize circumstantial variations in conditions. We normalized our results to the maximal diameter at an arterial pressure of 100 mmHg with tone intact. Because resistance is inversely proportional to diameter to the power of four, the highest diameter will have the largest positive effect on perfusion. Indeed, maximal diameter does occur in late diastole for the subendocardium and hence at the moment that muscle perfusion is highest. For the subepicardial vessels, maximal diameter was found during systole. However, perfusion of the subepicardium occurs both during systole and diastole, so maximal diameter of the subepicardial arterioles will also be an important parameter for local perfusion (2, 8). We have analyzed the influence of choice of this standardization by also calculating all responses using end diastolic diameters as is usually done in literature (5, 12). In our data, there is not much difference between subendocardial maximal and end-diastolic diameter, but for the subepicardial vessels there is some difference. However, the changes in diameter for decreases in pressure and with dilation are similar for maximal and end diastolic diameter (within 2% for all interventions except 30 mmHg without stenosis, in which the difference is 4%). Recalculation of the results using end-diastolic diameter therefore yielded similar results, indicating that dilation is indeed evidenced by an increase in maximal diameter.
Comparison to Literature
There are some major differences between the present study and earlier studies on in vivo coronary resistance vessels. We cannulated the left main coronary artery and used a perfusion system to change coronary arterial pressure. In other studies, coronary arterial pressure was decreased by application of a stenosis around either the left anterior descending or the left circumflex coronary artery (5, 12). Furthermore, we recorded not only steady-state diameter 15 s after the decrease in pressure but also the dynamic change in diameter due to the decrease in pressure, and we measured diameter changes during the whole cardiac cycle.In steady state we found less dilation of the subepicardial arterioles than previously reported (5, 12). It is important to realize that the dilatory responses are heterogeneous both in our study and in the other studies cited. Although the average data show no dilation at low pressure compared with the diameter of the arterioles at 100 mmHg, some of the individual vessels did dilate (subendocardial: 4, 4, and 2 out of 10 vessels dilated at pressures 70, 50, and 30 mmHg, respectively; subepicardial: 5, 4, and 3 out of 12 vessels dilated at 70, 50, and 30 mmHg, respectively). In the study of Chilian and Layne (5), ~65% of the arterioles smaller than 100 µm (n = 9) dilated at 40 mmHg, whereas none of the arterioles smaller than 100 µm (n = 4) dilated at 30 mmHg.
Furthermore, because of the application of the perfusion system which
contains a substantial extracorporeal volume, systolic left ventricular
pressure is slightly lower than under physiological conditions in the
dog. This may have resulted in activation of the baroreceptors in the
aortic arch and/or the carotid sinus, which may have resulted in
activation of several neurohumoral pathways aiming for an increase in
peripheral resistance and an increase in heart rate to maintain blood
pressure. Because we kept heart rate constant via atrial pacing,
maintenance of blood pressure could only be achieved by
vasoconstriction (most likely through activation of the
-adrenoceptors). We cannot exclude that activation of the
-adrenoceptors in the heart may have limited vasodilation in our
preparation especially in subendocardium.
Despite the fact that we did not observe dilation compared with the
diameter at 100 mmHg, flow was autoregulated at a perfusion pressure of
70 mmHg. Evidently, there are other factors involved in regulation of
flow besides the changes in arteriolar diameter in the vessels
observed. In a previous study (14) we reported that a
global reduction in coronary pressure results in an increase in
diastolic duration and therefore reduces extravascular resistance and
probably also reduces myocardial oxygen consumption. Based on data from
Bache and Cobb (2) and our previous paper
(14) we assumed that a 1% increase in the diastolic time
fraction resulted in a 2.6% decrease in resistance in the maximally
dilated coronary vasculature. Using this number and the increase in
diastolic time fraction at each pressure we calculated the decrease in
resistance due to the increase in the diastolic time fraction (shown as
RDTF in Table
2). Additionally we calculated the
decrease in resistance due to the increase in diameter using
Poiseuille's law (
Rdil in Table 2). We
compared the sum of these two to the actual change in resistance, based
on changes in pressure and flow (
Rflow in Table 2), and this way we could account for 65-99% of the change in resistance. The remaining change in resistance is due to other mechanisms such as recruitment (1). In the other studies
(5, 12) in which a segmental preparation was used,
extravascular resistance probably increased in the underperfused areas
because when part of the heart relaxes earlier, the surrounding
normally perfused tissue still contracts and may therefore stretch the part that is already relaxing. This stretch hinders perfusion of the
tissue and will therefore increase resistance and require additional
vasodilation.
|
Differences Between Endocardium and Epicardium
The subendocardium is more vulnerable to ischemia than the subepicardium. There are several observations in our study that may contribute to the explanation of this larger endocardial vulnerability.Response to pressure change. We found differences between subendocardial and subepicardial arterioles both in the narrowing response of maximal diameter to the initial decrease in pressure and in the subsequent dilation. The initial decrease in maximal diameter is larger for the subendocardial arterioles (Fig. 4). Hence, the subendocardial arterioles must dilate more to compensate for the passive decrease in diameter and therefore use more of their dilatory reserve in response to a similar decrease in pressure. The remaining dilatory reserve of the subendocardial arterioles may therefore fall short when myocardial demand is subsequently increased during an increase in heart rate.
The larger "passive" decrease in diameter in the subendocardium may be attributed to an increase in resistance of the intramural arteries upon a decrease in pressure in the large coronary arteries (6) resulting in a larger decrease in pressure in the subendocardium than in the subepicardium.Effect of stenosis. A stenosis in the coronary arteries not only results in a decrease in distal coronary perfusion pressure but decreases the pulsatility of flow as well. We showed that this hemodynamic aspect of a stenosis affects both subendocardial arterioles and mean coronary flow, whereas no difference in diameter of the subepicardial arterioles was found. Because the effect of a stenosis on mean flow disappears in the presence of L-NMMA, it is likely that it is caused by a change in nitric oxide (NO) production. NO production is directly related to shear stress on the endothelium. Shear stress is not constant during the cardiac cycle. Because flow to the subendocardium is more pulsatile than flow to the subepicardium, the maximal flow and maximal shear stress are likely to be higher as well. Consequently NO production in the subendocardium is higher than in the subepicardium, and perfusion of the subendocardium is more dependent on NO production. A decrease in flow pulsations by the stenosis will compromise NO production and thereby affect the subendocardium more than the subepicardium. In support of this theory are previous data from our group showing that dilation of the subendocardial arterioles in response to an occlusion (which is an extreme form of a stenosis) was more affected by L-NMMA than dilation of the subepicardial arterioles indicating that the perfusion of the subendocardium is indeed more dependent on NO than the subepicardium (18). Our data thereby suggests a mechanism by which pulsatile flow in the coronary circulation favors flow to the subendocardium by selectively increasing subendocardial NO production and thereby decreasing subendocardial resistance.
It is unlikely that the decrease in flow is caused by the difference in the arterial pressure profile (higher systolic pressure, lower diastolic pressure) induced by the stenosis (Fig. 1), because the stenosis had no effect on total flow in the presence of adenosine. Our observation that the presence of a stenosis, which increases arterial pressure pulsations, results in a decrease in coronary arterial flow seems in contrast with studies in both isolated arteries (9) and in the whole coronary vascular bed (15), which have shown that perfusion of the myocardium with pulsatile pressure (with an amplitude larger than 60 mmHg) induces vasodilation compared with perfusion at constant pressure. This apparent contradiction may be explained by comparing the effect of pulsatile perfusion pressure on local transmural pressure, being the difference between intravascular and extravascular pressure. Perfusion of the large coronary arteries with pulsatile pressure compared with constant pressure certainly increases the pressure pulse in the subepicardial arteries, but it is questionable what happens on the endocardial side. In our case, the stenosis in the coronary arteries increased the intravascular pressure pulsations to 37 ± 9 mmHg by increasing systolic intravascular pressure and decreasing diastolic intravascular pressure. Because subendocardial extravascular pressure (left ventricular pressure) also increases during systole and decreases during diastole, the difference between intravascular pressure and extravascular pressure becomes smaller both during systole and diastole as is evidenced by the decrease in diameter pulsations in the presence of the stenosis in our study. Therefore, despite the increase in intravascular pressure pulsations, the local subendocardial transmural pulsation amplitude may decrease resulting in constriction of the subendocardial arterioles. Such a specific effect on the subendocardial resistance vessels may therefore be a serious factor in the limitation of subendocardial perfusion in the presence of a stenosis and may contribute to the larger subendocardial vulnerability to ischemia. In summary, a decrease in pressure results in a larger initial decrease in diameter of the subendocardial arterioles than in the subepicardial arterioles. Furthermore, a stenosis selectively decreases the dilatory response of subendocardial arterioles as well as coronary blood flow. The effect of a stenosis on coronary blood flow may be due to a decrease in NO production caused by the stenosis. These findings are consistent with findings that endocardial perfusion is more reduced by a stenosis than epicardial perfusion.| |
ACKNOWLEDGEMENTS |
|---|
Assistance of Ms. Ogi with the data analysis is greatly appreciated.
| |
FOOTNOTES |
|---|
Financial support from the Netherlands Heart Foundation (Grant 92.128) and the Netherlands Organization for Scientific Research (NWO, Grant R90-160) is gratefully acknowledged.
Address for reprint requests and other correspondence: J. A. E. Spaan, Dept. of Medical Physics, Cardiovascular Research Institute Amsterdam, Academic Medical Center, Univ. of Amsterdam, Meibergdreef 15, 1105 AZ Amsterdam, PO Box 22700, 1100 DE Amsterdam, The Netherlands (E-mail: j.a.spaan{at}amc.uva.nl).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 2 February 2000; accepted in final form 9 November 2000.
| |
REFERENCES |
|---|
|
|
|---|
1.
Austin, RE,
Aldea GS,
Coggins DL,
Flynn AE,
and
Hoffman JIE
Profound spatial heterogeneity of coronary reserve. Discordance between patterns of resting and maximal myocardial blood flow.
Circ Res
67:
319-331,
1990
2.
Bache, RJ,
and
Cobb FR.
Effect of maximal coronary vasodilation on transmural myocardial perfusion during tachycardia in the awake dog.
Circ Res
41:
648-653,
1977
3.
Canty, JM.
Coronary pressure-function and steady-state pressure-flow relations during autoregulation in the unanesthetized dog.
Circ Res
63:
821-836,
1988
4.
Chilian, WM.
Microvascular pressures and resistances in the left ventricular subepicardium and subendocardium.
Circ Res
69:
561-570,
1991
5.
Chilian, WM,
and
Layne SM.
Coronary microvascular responses to reductions in perfusion pressure. Evidence for persistent arteriolar vasomotor tone during coronary hypoperfusion.
Circ Res
66:
1227-1238,
1990
6.
Cornelissen, AJ,
Dankelman J,
VanBavel E,
Stassen HG,
and
Spaan JA.
Myogenic reactivity and resistance distribution in the coronary arterial tree: a model study.
Am J Physiol Heart Circ Physiol
278:
H1490-H1499,
2000
7.
Dankelman, J,
Spaan JA,
Van der Ploeg CP,
and
Vergroesen I.
Dynamic response of the coronary circulation to a rapid change in its perfusion in the anaesthetized goat.
J Physiol (Lond)
419:
703-715,
1989
8.
Flynn, AE,
Coggins DL,
Goto M,
Aldea GS,
Austin RE,
Doucette JW,
Husseini W,
and
Hoffman JIE
Does systolic subepicardial perfusion come from retrograde subendocardial flow?
Am J Physiol Heart Circ Physiol
262:
H1759-H1769,
1992
9.
Goto, M,
VanBavel E,
Giezeman MJMM,
and
Spaan JAE
Vasodilatory effect of pulsatile pressure on coronary resistance vessels.
Circ Res
79:
1039-1045,
1996
10.
Gould, KL.
Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation.
Circ Res
43:
242-253,
1978
11.
Gould, KL.
Phasic pressure-flow and fluid-dynamic analysis.
In: Coronary Artery Stenosis and Reversing Atherosclerosis (2nd ed.). London, UK: Arnold, 1998, p. 55-66.
12.
Kanatsuka, H,
Lamping KG,
Eastham CL,
and
Marcus ML.
Heterogenous changes in epimyocardial microvascular size during graded coronary stenosis. Evidence of the microvascular site for autoregulation.
Circ Res
66:
389-396,
1990
13.
Kanatsuka, H,
Sekiguchi N,
Akai K,
Wang Y,
Komaru T,
Ashikawa K,
and
Takishima T.
Microvascular sites and mechanisms responsible for reactive hyperemia in the coronary circulation of the beating canine heart.
Circ Res
71:
912-922,
1992
14.
Merkus, D,
Kajiya F,
Vink H,
Vergroesen I,
Dankelman J,
Goto M,
and
Spaan JA.
Prolonged diastolic time fraction protects myocardial perfusion when coronary blood flow is reduced.
Circulation
100:
75-81,
1999
15.
Recchia, FA,
Senzaki H,
Saeki A,
Byrne BJ,
and
Kass DA.
Pulse pressure-related changes in coronary flow in vivo are modulated by nitric oxide and adenosine.
Circ Res
79:
849-856,
1996
16.
Spaan, JAE,
Breuls NPW,
and
Laird JD.
Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog.
Circ Res
49:
584-593,
1981
17.
Spaan, JAE,
Breuls NPW,
and
Laird JD.
Forward coronary flow normally seen in systole is the result of both forward and concealed back flow.
Basic Res Cardiol
76:
582-586,
1981[ISI][Medline].
18.
Yada, T,
Hiramatsu O,
Kimura A,
Goto M,
Ogasawara Y,
Tsujioka K,
Yamamori S,
Ohno K,
Hosaka H,
and
Kajiya F.
In vivo observation of subendocardial microvessels of the beating porcine heart using a needle-probe videomicroscope with a CCD camera.
Circ Res
72:
939-946,
1993
19.
Yada, T,
Hiramatsu O,
Kimura A,
Tachibana H,
Chiba Y,
Lu S,
Goto M,
Ogasawara Y,
Tsujioka K,
and
Kajiya F.
Direct in vivo observation of subendocardial arteriolar response during reactive hyperaemia.
Circ Res
77:
622-631,
1995
This article has been cited by other articles:
![]() |
A. R. Pries, H. Habazettl, G. Ambrosio, P. R. Hansen, J. C. Kaski, V. Schachinger, H. Tillmanns, G. Vassalli, I. Tritto, M. Weis, et al. A review of methods for assessment of coronary microvascular disease in both clinical and experimental settings Cardiovasc Res, June 25, 2008; (2008) cvn136v2. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Westerhof, C. Boer, R. R. Lamberts, and P. Sipkema Cross-talk between cardiac muscle and coronary vasculature. Physiol Rev, October 1, 2006; 86(4): 1263 - 1308. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Sorop, E. N. T. P. Bakker, A. Pistea, J. A. E. Spaan, and E. VanBavel Calcium channel blockade prevents pressure-dependent inward remodeling in isolated subendocardial resistance vessels Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1236 - H1245. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Tawakol, R. Q. Migrino, K. S. Aziz, J. Waitkowska, G. Holmvang, N. M. Alpert, J. E. Muller, A. J. Fischman, and H. Gewirtz High-Dose Folic Acid Acutely Improves Coronary Vasodilator Function in Patients With Coronary Artery Disease J. Am. Coll. Cardiol., May 17, 2005; 45(10): 1580 - 1584. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. Fokkema, J. W. G. E. VanTeeffelen, S. Dekker, I. Vergroesen, J. B. Reitsma, and J. A. E. Spaan Diastolic time fraction as a determinant of subendocardial perfusion Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2450 - H2456. [Abstract] [Full Text] [PDF] |
||||
![]() |
B.-J. Verhoeff, M. Siebes, M. Meuwissen, B. Atasever, M. Voskuil, R. J. de Winter, K. T. Koch, J. G.P. Tijssen, J. A.E. Spaan, and J. J. Piek Influence of Percutaneous Coronary Intervention on Coronary Microvascular Resistance Index Circulation, January 4, 2005; 111(1): 76 - 82. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Sato, H. Yaoita, K. Maehara, and Y. Maruyama Attenuation of heart failure due to coronary stenosis by ACE inhibitor and angiotensin receptor blocker Am J Physiol Heart Circ Physiol, June 5, 2003; 285(1): H359 - H368. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |