ABSTRACT |
|---|
|
|
|---|
We have determined the cross-sectional area (CSA) compliance of the first several generations of pig coronary arteries and the volume compliance of the coronary arterial tree (vessels >0.5 mm in diameter) using a videodensitometric technique. The coronary arteries of four KCl-arrested maximally vasodilated pig hearts were perfused with iodine and 3% Cab-O-Sil. Because Cab-O-Sil occludes small arteries, the flow can be stopped and the pressure can be maintained while the trunk of the coronary artery and its subbranches are imaged using digital angiography. The coronary arteries were preconditioned several times with cyclic changes in pressure from 0 to 160 mmHg. The pressure was then varied in a triangular pattern, and the absolute CSA of each vessel and the total arterial volume were calculated using videodensitometry in conjunction with digital subtraction angiography. Our results have shown that the pressure-diameter and pressure-volume relationships are linear in the 60-140 mmHg pressure range. Furthermore, the compliance of the coronary arteries is small; i.e., the diameter of the coronary artery changes by <15% in the 80-mmHg pressure range. The compliance data couples the mechanics of the blood vessel wall to the mechanics of blood flow to yield a pressure-flow relationship for each coronary arterial segment.
distensibility; pressure-diameter relationship; digital subtraction angiography; videodensitometry
| |
INTRODUCTION |
|---|
|
|
|---|
IT IS WELL ESTABLISHED that the passive mechanical properties of blood vessel walls are important determinants of the pressure-flow (P-Q) relationship, the speed of pulse waves in vessels, the stress distribution in vessel walls, and the phenomena of mass transport through arterial walls (11). For these reasons the mechanical properties of coronary arteries have been studied extensively (2, 6, 13, 14, 16, 24, 29, 32, 36). Gregg and colleagues (16) measured (using mercury) the pressure-volume (P-V) relationship of the coronary arterial tree of dogs. Patel and Janicki (29) determined the pressure-diameter (P-D) relationship of segments of isolated left circumflex arteries of dogs. Douglas and Greenfield (6) measured the dynamic P-V relation of dog coronary arteries by obstructing the distal coronary bed with 200-µm-diameter beads. Additionally, Manor and co-workers (24) made in vivo measurements of P-V relationships of epicardial coronary arteries in dogs. The inverse of distensibility (stiffness) was determined for dog coronary arteries by Arts and colleagues (2) and Reneman and Arts (32) from wave-velocity measurements in vivo. The P-D relationship of excised coronary arteries from dogs and humans was measured by Gow and co-workers (14) and Gow and Hadfield (13), respectively; the diameters were recorded using an electrical caliper over a range of pressures. Tomoike and colleagues (36) also measured the P-D relationship of dog coronary arteries in situ (in the beating heart) using an ultrasonic dimension gauge with piezoelectric crystals. More recently, inflation and extension tests on isolated passive bovine, human, and porcine coronary arteries has been reported by Kang and co-workers (18) and Carmines and colleagues (4), respectively. Kang et al.'s study (18) revealed the general characteristics of heat-induced behavior, and Carmines et al.'s work (4) was used to formulate a two-dimensional stress-strain relationship.
Although these studies have yielded a wealth of quantitative information on the distensibility of some parts of the coronary vasculature, a systematic set of data on blood vessel elasticity in the pig heart does not exist. In this study, we present a systematic database on the compliance [the pressure-cross-sectional area (P-CSA) relationship] of the first several generations of the coronary arteries and the compliance of arterial volume (the P-V relationship).
| |
METHODS |
|---|
|
|
|---|
Isolated heart preparation. The studies were performed on four Duroc pigs weighing 19.3 ± 4.1 kg (range 15-24 kg). Surgical anesthesia was induced with ketamine (33 mg/kg im) and atropine (0.05 mg/kg im) and maintained with halothane (1-2%). Ventilation with 100% O2 was provided with a Harvard respiratory pump. Ventilator settings were adjusted during the experiments to maintain PO2 and PCO2 within normal values. A midline sternotomy was performed and anticoagulation was induced with heparin (100 U/kg). An incision was made in the pericardium and the heart was supported in a pericardial cradle. The heart was arrested with a saturated KCl solution administered through a jugular vein. The heart was then excised with the ascending aorta clamped (to keep air bubbles out of the coronary vessels) and placed in a saline bath at room temperature. The right coronary artery (RCA) was ligated, and the left anterior descending (LAD) and left circumflex arteries were cannulated under saline to avoid air bubbles. The left coronary arteries were immediately perfused with an isoosmotic cardioplegic rinsing solution as described by Kassab and colleagues (20) to maintain a relaxed myocardium and a vasodilated vasculature. Nitroglycerin (30 µM) was added to the cardioplegic solution to dilate the large coronary arteries.
Determination of the P-CSA relationship. The method of quantitative coronary angiography was used to determine the elasticity of the coronary arteries (vessels >0.5 mm in diameter) in the isolated heart preparation. The left coronary arteries were perfused with iodinated contrast material (Omnipaque; Nycomed Amersham; Princeton, NJ) and 3% Cab-O-Sil (Eastman Kodak), which is a colloidal silica that forms agglomerated particles with effective diameters that exceed those of small arteries (20). Hence the flow of iodine is zero during mechanical testing such that the imposed pressure is uniform throughout the coronary arteries that were imaged using digital subtraction angiography. The postmortem imaging experiments were completed within 1-2 h of euthanasia.
The arterial CSA change, as a function of pressure, was recorded for various vessel sizes. The coronary arteries were preconditioned with five cyclic changes in pressure from 0 to 160 mmHg, a procedure that improves the reproducibility of the stress-strain curves of the arteries (10). The pressure was varied in a triangular pattern with a slope of ~1 mmHg/s. Coronary arteriograms were acquired at 1 frame every 5 s during the loading and unloading processes. The imposed pressure and X-ray tube voltage were continuously recorded (Biopac Systems; Santa Barbara, CA). This information was used to determine the arterial pressure during each image acquisition. For calibration purposes, a cylindrical vessel phantom that consisted of plastic tubing with different inside diameters (ranging from 0.95 to 4.75 mm) filled with contrast material was imaged over the heart region. The integrated gray levels in the vessel profiles were related to the known CSA values of the vessel phantoms. This information was used to directly convert the integrated gray levels to CSA values for the coronary angiograms. Once the CSA was measured, the effective diameter (D) could be easily computed (D = 4CSA1/2/
) for various
pressures assuming that the coronary arteries were cylindrical.
Image acquisition and processing. All images were acquired using a conventional X-ray tube (Dynamax 79-45/120; Machlett Laboratories; Stamford, CT), a constant potential X-ray generator (Optimus M200; Philips Medical Systems; Shelton, CT), a 23/15-cm cesium-iodine image intensifier, a focused grid (8:1 grid ratio, 36 lines/cm), and a charge-coupled device camera (Multicam MC-1134GN; Texas Instruments; Dallas, TX). Light intensity for the camera was controlled by an adjustable aperture. The video signal was linearly digitized to 640 × 480 × 8-bit precision using a Matrox Pulsar frame grabber (Matrox Electronics Systems; Dorval, Quebec, Canada) and a Pentium III computer.
The images were acquired using the 15-cm image-intensifier mode and the large (1.2 mm nominal) focal spot. Corrections were made for the spatially varying scatter and veiling glare. A convolution-filtering technique was employed to estimate scatter-glare distribution in images to avoid the need to sample the scatter-glare intensity for each experiment (8). This technique utilizes exposure parameters and the detected intensity distribution to estimate scatter-glare intensity by prediction of the total thickness at every pixel in the image. The thickness information is used to estimate scatter glare on a pixel-by-pixel basis.Determination of the P-V relationship. The determination of coronary arterial volume using digital angiography was recently reported (39). In brief, temporal subtraction images were formed after the images were corrected for scatter and veiling glare (8). A region of interest (ROI) that approximately outlined the visible epicardial arteries was manually drawn. A narrow background shell was drawn just outside the arterial ROI. The background ROI was used to correct for the iodine signal in the myocardium. The integrated videodensitometric signal was converted to iodine mass by using the system iodine-calibration curve. The calculated iodine mass was converted to volume by using the known iodine concentration of the contrast material.
Data analysis.
Blood vessels were grouped in size ranges corresponding to the largest
three orders, and respective P-CSA values were determined. Kassab and
colleagues (20) have previously shown that the diameter ranges of 0.5-1.0, 1.01-2.0, and 2.01-3.5 mm correspond
to orders 9, 10, and 11, respectively.
The P-D relationships were computed from the P-CSA values
for the cylindrical arterial vessels. The P-D relationships
in the 60- to 140-mmHg pressure range were then curve-fitted using
linear regression, and the respective compliances were determined. The
elastic deformation can be described by the equation D =
P +
, where D is the diameter at a given
intravascular pressure (P) and
and
are constants. For the ease
of comparing the compliance (
) of different-sized vessels, we
computed the distensibility of each vessel segment by normalizing the
compliance with respect to the diameter at the in vivo pressure (taken
as 100 mmHg). Student's t-test and ANOVA were used to
detect differences in compliance among the various sized vessels within
a heart and among different hearts.
| |
RESULTS |
|---|
|
|
|---|
A typical postmortem coronary angiogram that was used to measure
the CSA and volume of the different branches of the coronary arterial
tree is shown in Fig. 1. The CSA and
volume were determined from images corresponding to different
pressures. The P-CSA relationship for an epicardial artery is shown in
Fig. 2; the hysteresis loop can be seen
during the loading and unloading ramps of pressure. The loading P-CSA
relationship for the first several generations of left coronary
arteries is shown in Fig. 3. The
P-D relationship was computed from these data assuming that
the coronary arteries had a circular cross section (as described in
METHODS). Our results show that the P-D
relationship is linear in the 60- to 140-mmHg pressure range. The
means ± SD of
and
were computed using a linear
least-squares fit in the 60- to 140-mmHg pressure range; these are
summarized in Table 1 for the three
largest orders. It is apparent that the compliance of the coronary
arteries is small; i.e., the diameter of the coronary artery changes by
<15% (5.4, 9.6, and 13% for orders 11, 10, and
9, respectively) in the 80-mmHg pressure range.
|
|
|
|
The P-V relationship is also found to be linear in the same pressure
range. The mean ± SD of the volume compliance of the four hearts
was found to be (1.1 ± 0.45) × 10
3 ml/mmHg
(R2 = 0.965-0.999). The corresponding
volume distensibility was found to be (1.1 ± 0.36) × 10
3 mmHg
1 (R2 = 0.972-0.999). Figure 4 shows
an example of the hysteresis loop of the P-V relationship for the main
branches of the LAD arterial tree (vessels >0.5 mm in diameter).
Figure 5 shows the loading P-V
relationships of the four animals. The volume was normalized with
respect to the volume at 100 mmHg.
|
|
| |
DISCUSSION |
|---|
|
|
|---|
Videodensitometry. In the present study, the CSA and volume of the coronary arteries were determined using videodensitometric techniques. Using digital subtraction coronary arteriography, Molloi and colleagues (25-27) previously investigated new X-ray imaging techniques for quantification of coronary arterial CSA and volume. Videodensitometry techniques are based on the theoretical relationship between the thickness of contrast material present in the path of an incident X-ray beam and the detected intensity. The integrated gray levels along a scan line perpendicular to a vessel in a logarithmically transformed image yield a measurement of the CSA of the vessel if the nonlinear degradation factors (such as X-ray scatter, veiling glare, and beam hardening) are negligible or corrected (23, 25, 26). The advantage of these techniques is that it is possible to quantitate absolute CSA without any assumption regarding the cross-sectional geometry. Moreover, the integrated gray levels in a vessel segment can result in a measurement of the lumen volume. These methods were used in the present study to quantitate the P-CSA relationship of the large left coronary arteries and the P-V relationship of the coronary arterial tree proximal to vessels of 0.5 mm in diameter.
Mechanical properties of blood vessels. It is well known that blood vessels exhibit viscoelastic properties (10) such as creep (time-dependent increase in length while force is constant), relaxation (time-dependent decrease in force while length is constant), and hysteresis (differences in the loading and unloading curves). In the present study, we focused on the initial elastic response of the coronary vessels, which can be expressed in terms of compliance, distensibility, stiffness, or elastic modulus. Compliance is defined as the change in luminal dimension (diameter, CSA, or volume) divided by the corresponding change in pressure; stiffness is the reciprocal of compliance, and distensibility is a normalized compliance. Compliance can be measured under static or dynamic loading; the latter is referred to as the dynamic compliance or capacitance. In the present study, the loading history was relatively slow (i.e., slope of the ramp was ~1 mm/s). Hence the reported measurements correspond to those of a static compliance.
Variation of distensibility with vessel diameter.
It can be shown that the distensibility
[(
D/D0)/
P] of a vessel is
proportional to the diameter-wall thickness ratio
(D/h) of the vessel and inversely proportional to
the Young's modulus (E) of the vessel wall material
(38); i.e.,
(
D/D0)/
P = (D/2h)(1/E), where D0 is
the diameter at 0 pressure. Our data show a statistically significant decrease in distensibility as vessel diameter increases (P = 0.001). This may be either due to a change in the
diameter-to-wall thickness ratio or a change in Young's modulus due to
changes in the proportion of various microstructural components (e.g., elastin, collagen, smooth muscle cells, ground substance, etc.). The
variation in distensibility with diameter of coronary arteries is
similar to that of pulmonary veins in cats (37).
Application of P-D relationship: determination of P-Q relationship of coronary circulation. The question of mechanical properties can be formulated in many different ways. The P-D relationship has been extremely popular among cardiovascular physiologists because it plays an important role in the P-Q relationship of blood flow through an organ. Indeed, it can be shown that the compliance of the vasculature is an important determinant of the nonlinearity of the P-Q relationship (9). Kassab (19) has recently shown that a linear P-D relationship and a small compliance lead to a second-order P-Q relationship in a vessel segment. The second-order relationship is a modification of Poiseuille's law, which takes into account the distensibility of the blood vessel under the conditions of Newtonian steady-state laminar flow. Distensibility data in the literature suggest that the smaller coronary arteries and arterioles also obey a linear P-D relationship in the physiological pressure range with relatively small compliance (see review in Ref. 5). Hence the second-order P-Q relationship may hold in the various segments of the coronary arterial tree. It should be noted, however, that in addition to compliance, the curvature of the P-Q relationship depends on a number of other factors such as the geometry and branching pattern of the vascular network, vessel-myocardium interaction, vascular tone, and blood rheology. It is interesting to note that in a diastolic vasodilated coronary vasculature the P-Q relationship reveals a second-order relationship (17).
Nonlinearity of the P-D relationship.
Our results show that the P-D relationship is nonlinear over
the full range of pressure (0-160 mmHg). The P-D
relationship will be linear if
D(2hE)
1 remains constant as the
pressure varies. In general, with increasing pressure, D
increases and h decreases, whereas E increases
(12, 30). The P-D relationship will remain
linear only if the changes in D and hE are
proportional. In the present study, we found that this occurs over the
60- to 140-mmHg pressure range. The linearity between pressure and
diameter for the coronary arteries has been reported by other
investigators in a similar pressure range (13, 14, 29,
36).
Comparison with other works.
In Table 2, the diameter-distensibility
data determined in this study are compared with those from the
literature. Our results are in agreement with the in vivo and in vitro
data from dogs (14, 29, 36). There are differences,
however, between the elasticity of human coronary arteries and those of
dogs and pigs (13). These differences are likely due to
postmortem changes, because the human coronary arteries were stored
overnight before being measured.
|
3
ml/mmHg at a mean pressure of 80 mmHg. Subsequently, Patel and Janicki
(29), using a similar method, obtained a value of 0.5 × 10
3 ml/mmHg. These data are in agreement with the
value of (1.1 ± 0.45) × 10
3 ml/mmHg in the
pressure range of 60-140 mmHg that was found in the present study.
Critique of methods. Because edema may have an important effect on the distensibility of the coronary vessels, we attempted to prevent it in our isolated heart preparation. To avoid edema, we restricted the highest perfusion pressure to 160 mmHg. Furthermore, the cardioplegic solution used to perfuse the heart contained 6% dextran to ensure proper colloidal osmotic pressure. Finally, the hearts were weighed immediately after removal from the animal and at the conclusion of the distensibility experiments. We did not find a statistically significant change in heart weight. Hence it can be concluded that there was no significant edema in our isolated heart preparations.
An additional concern with a nonbeating isolated heart preparation is the accumulation of iodine in the tissue during the experiment. Because iodine is not washed out, it accumulates in the tissue of the passive arrested heart. Dimensional measurements (particularly volume) may be sensitive to this accumulation; therefore we were very careful about the choice of the ROI for volume measurements, and we excluded smaller vessels where iodine accumulation makes the vessel edge less distinguishable. We estimated the amount of diffused iodine and found it to be ~1% during the time of measurements. Finally, the compliance data in the present study correspond to those of dilated myocardium and vessels. Because the compliance of the myocardium and the smooth muscle tone of the blood vessels varies throughout the cardiac cycle and depends on the state of the heart, it is important to determine the compliance in a well-defined and reproducible state. The effects of myocardial contraction and smooth muscle tone can then be studied in relation to the relaxed myocardium in the vasodilated state. Myocardial contraction will increase the compliance of the vessels whereas the tone of vascular smooth muscle will decrease it.Future investigations. The mechanical properties of blood vessels are derived from collagen and elastin fibers, smooth muscle cells, and ground substances. There are numerous references in the literature to blood vessels and corresponding material components (see review in Ref. 11). The mechanical properties of blood vessels depend not only on the intrinsic properties of the blood vessel wall but also on the properties of neighboring tissue. The intramural coronary blood vessels are embedded in the myocardium where the interactions of blood pressure, vessel elasticity, smooth muscle tone, and tissue stress lead to complex time-dependent interactions between blood flow and muscle contraction. The transient muscle-vessel interaction is an important determinant of blood flow because the period of the cardiac cycle is considerably smaller than the time constant of coronary blood flow (35). The dynamics of the muscle-vessel interaction have been a subject of great interest to coronary physiologists. The systolic extravascular resistance model (15, 33), waterfall model (7, 31), nonlinear intramyocardial pump model (1, 3), and variable elastance model (21, 22) have all been proposed to explain interactions between contraction and coronary blood flow. Hence a study of vessel compliance must take into account the vessel-myocardium interaction. The vessel-myocardium interaction is small for the large epicardial vessels (orders 10 and 11) and becomes more significant for the smaller intramural vessels (orders <10). Therefore the interaction of muscle contraction and intramural blood vessel elasticity during the cardiac cycle remains to be studied.
| |
ACKNOWLEDGEMENTS |
|---|
The authors thank Dr. John Breault and Ayesha Mian for excellent technical assistance.
| |
FOOTNOTES |
|---|
This research was supported in part by National Heart, Lung, and Blood Institute Grant 5-R29-HL-55554 (to G. S. Kassab) and by an Established Investigation Award from the American Heart Association (to S. Molloi).
Address for reprint requests and other correspondence: G. S. Kassab, Dept. of Bioengineering, Univ. of California, 9500 Gilman Dr., La Jolla, CA 92093-0412 (E-mail: kassab{at}bioeng.ucsd.edu).
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
Received 16 December 2000; accepted in final form 21 March 2001.
| |
REFERENCES |
|---|
|
|
|---|
1.
Arts, MGJ
A Mathematical Model of the Dynamics of the Left Ventricle and the Coronary Circulation (PhD thesis). Maastricht, The Netherlands: University of Limburg, 1978.
2.
Arts, T,
Kruger RTI,
Van Gerven W,
Lambregts JAC,
and
Reneman RS.
Propagation velocity and reflection of pressure waves in the canine coronary artery.
Am J Physiol Heart Circ Physiol
237:
H469-H474,
1979
3.
Bruinsma, P,
Arts T,
Dankelman J,
and
Spaan JAE
Model of the coronary circulation based on pressure dependence of coronary resistance and compliance.
Basic Res Cardiol
83:
510-524,
1988[Web of Science][Medline].
4.
Carmines, DV,
McElhaney JH,
and
Stack R.
A piece-wise nonlinear elastic stress expression of human and pig coronary arteries tested in vitro.
J Biomech
24:
899-906,
1991[Web of Science][Medline].
5.
Cornelissen, AJ,
Dankelman J,
VanBavel E,
Stassen HG,
and
Spaan JA.
Myogenic reactivity and resistance distribution in the coronary arterial tree: a model study.
Am J Physiol Heart Circ Physiol
278:
H1490-H1499,
2000
6.
Douglas, JE,
and
Greenfield JC.
Epicardial coronary artery compliance in the dog.
Circ Res
27:
921-929,
1970
7.
Downey, JM,
and
Kirk ES.
Inhibition of coronary blood flow by a vascular waterfall mechanism.
Circ Res
36:
753-760,
1975
8.
Ersahin, A,
Molloi S,
and
Yao-Jin Q.
A digital filtration technique for scatter-glare correction based on thickness estimation.
IEEE Trans Med Imaging
14:
587-595,
1995[Medline].
9.
Fung, YC.
Biodynamics: Circulation. New York: Springer-Verlag, 1984.
10.
Fung, YC.
Biomechanics: Mechanical Properties of Living Tissues. New York: Springer-Verlag, 1993.
11.
Fung, YC.
Biomechanics: Motion, Flow, Stress, and Growth. New York: Springer-Verlag, 1990.
12.
Fung, YC,
Fronek K,
and
Patitucci P.
Pseudoelasticity of arteries and the choice of its mathematical expression.
Am J Physiol Heart Circ Physiol
237:
H620-H631,
1979
13.
Gow, BS,
and
Hadfield CD.
The elasticity of canine and human coronary arteries with reference to postmortem changes.
Circ Res
45:
588-594,
1979
14.
Gow, BS,
Schonfeld D,
and
Patel DJ.
The dynamic elastic properties of the canine left circumflex coronary artery.
J Biomech
7:
389-395,
1974[Web of Science][Medline].
15.
Gregg, DE,
and
Green HD.
Registration and interpretation of normal phasic inflow into a left coronary artery by an improved differential manometric method.
Am J Physiol
130:
114-125,
1940.
16.
Gregg, DE,
Green HD,
and
Wiggers CJ.
Phasic variations in peripheral coronary resistance and their determinants.
Am J Physiol
112:
362-373,
1935.
17.
Hoffman, JIE,
and
Spaan JAE
Pressure-flow relations in the coronary circulation.
Physiol Rev
70:
331-390,
1990
18.
Kang, T,
Resar J,
and
Humphrey JD.
Heat-induced changes in the mechanical behavior of passive coronary arteries.
J Biomech Eng
117:
86-93,
1995[Web of Science][Medline].
19.
Kassab, GS.
Analysis of coronary circulation: a bioengineering approach.
In: Introduction to Bioengineering, edited by Fung YC.. Singapore: World Scientific, 2001, p. 93-105.
20.
Kassab, GS,
Rider CA,
Tang NJ,
and
Fung YCB
Morphometry of pig coronary arterial trees.
Am J Physiol Heart Circ Physiol
265:
H350-H365,
1993
21.
Krams, R,
Sipkema P,
and
Westerhof N.
Can coronary systolic-diastolic flow difference be predicted by left ventricular pressure or time-varying intramyocardial elastance?
Basic Res Cardiol
84:
149-159,
1989[Web of Science][Medline].
22.
Krams, R,
Sipkema P,
Zegers J,
and
Westerhof N.
Contractility is the main determinant of coronary systolic flow impediment.
Am J Physiol Heart Circ Physiol
257:
H1936-H1944,
1989
23.
Kruger, RA.
Estimation of the diameter of and iodine concentration within blood vessels using digital radiography devices.
Med Phys
8:
652-658,
1981[Web of Science][Medline].
24.
Manor, D,
Beyar R,
Shofti R,
and
Sideman S.
In-vivo study of the mechanical properties of epicardial coronary arteries.
J Biomech Eng
116:
131-132,
1994[Web of Science][Medline].
25.
Molloi, S,
Ersahin A,
Hicks J,
and
Wallis J.
In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.
Int J Card Imaging
11:
223-231,
1995[Web of Science][Medline].
26.
Molloi, SY,
Ersahin A,
Roeck WW,
and
Nalcioglu O.
Absolute cross-sectional area measurements in quantitative coronary arteriography by dual-energy DSA.
Invest Radiol
26:
119-127,
1991[Web of Science][Medline].
27.
Molloi, S,
Zhang W,
Leung C,
Hiro T,
and
Hicks J.
Measurement of a cross-sectional area of normal and stenotic arteries with videodensitometric quantitative arteriography and intravascular ultrasound.
Acad Radiol
4:
245-252,
1997[Web of Science][Medline].
28.
Morgenstern, C,
Holjes U,
Arnold G,
and
Lockner W.
The influence of coronary pressure and coronary flow on intracoronary blood volume and geometry of the left ventricle.
Pflügers Arch
340:
101-111,
1973[Web of Science][Medline].
29.
Patel, DJ,
and
Janicki JS.
Static elastic properties of the left coronary circumflex artery and the common carotid artery in dogs.
Circ Res
2:
149-158,
1970.
30.
Patel, DJ,
and
Vaishnav RN.
The rheology of large blood vessels.
In: Cardiovascular Fluid Dynamics, edited by Bergel DH.. New York: Academic, 1972, vol. 2, p. 2-65.
31.
Permutt, S,
and
Riley RL.
Hemodynamics of collapsible vessels with tone: the vascular waterfall.
J Appl Physiol
18:
924-932,
1963
32.
Reneman, RS,
and
Arts T.
Dynamic capacitance of epicardial coronary arteries in vivo.
J Biomech Eng
107:
29-33,
1985[Web of Science][Medline].
33.
Sabiston, DC,
and
Gregg DE.
Effect of cardiac contraction on coronary blood flow.
Circulation
15:
14-20,
1957[Web of Science][Medline].
34.
Salisbury, PF,
Cross CE,
and
Rieben PA.
Physiological factors influencing coronary blood volume in isolated dog hearts.
Am J Physiol
200:
633-636,
1961.
35.
Spaan, JAE
Coronary diastolic pressure-flow relation and zero-flow pressure explained on the basis of intramyocardial compliance.
Circ Res
56:
293-309,
1985
36.
Tomoike, H,
Ootsubo H,
Sakai K,
Kikuchi Y,
and
Nakamura M.
Continuous measurement of coronary artery diameter in situ.
Am J Physiol Heart Circ Physiol
240:
H73-H79,
1981.
37.
Yen, RT,
and
Foppiano L.
Elasticity of small pulmonary veins in the cat.
J Biomech Eng
103:
38-43,
1981[Web of Science][Medline].
38.
Yen, RT,
Fung YC,
and
Bingham N.
Elasticity of small pulmonary arteries in the cat.
J Biomech Eng
102:
900-907,
1980.
39.
Zhou, Y.
Quantitative Assessment of Diffuse Coronary Artery Disease Using Digital Angiography (PhD thesis). Irvine: University of California, 2000.
This article has been cited by other articles:
![]() |
Y. Huo and G. S. Kassab Effect of compliance and hematocrit on wall shear stress in a model of the entire coronary arterial tree J Appl Physiol, August 1, 2009; 107(2): 500 - 505. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Huo and G. S. Kassab Pulsatile blood flow in the entire coronary arterial tree: theory and experiment Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1074 - H1087. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. A. Rogers, T. Kiyooka, and W. M. Chilian Is there a need for another model on the pulsatile nature of coronary blood flow? Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1034 - H1035. [Full Text] [PDF] |
||||
![]() |
G. S. Kassab Scaling laws of vascular trees: of form and function Am J Physiol Heart Circ Physiol, February 1, 2006; 290(2): H894 - H903. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S. Kassab Functional hierarchy of coronary circulation: direct evidence of a structure-function relation Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2559 - H2565. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Kalsho and G. S. Kassab Bifurcation asymmetry of the porcine coronary vasculature and its implications on coronary flow heterogeneity Am J Physiol Heart Circ Physiol, December 1, 2004; 287(6): H2493 - H2500. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Guo and G. S. Kassab Distribution of stress and strain along the porcine aorta and coronary arterial tree Am J Physiol Heart Circ Physiol, June 1, 2004; 286(6): H2361 - H2368. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Lu, J. Yang, J. B. Zhao, H. Gregersen, and G. S. Kassab Shear modulus of porcine coronary artery: contributions of media and adventitia Am J Physiol Heart Circ Physiol, November 1, 2003; 285(5): H1966 - H1975. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. H. Hamza, Q. Dang, X. Lu, A. Mian, S. Molloi, and G. S. Kassab Effect of passive myocardium on the compliance of porcine coronary arteries Am J Physiol Heart Circ Physiol, July 11, 2003; 285(2): H653 - H660. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |