AJP - Heart Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 285: H1411-H1419, 2003. First published June 12, 2003; doi:10.1152/ajpheart.00307.2003
0363-6135/03 $5.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
285/4/H1411    most recent
00307.2003v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (60)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsai, A. G.
Right arrow Articles by Winslow, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsai, A. G.
Right arrow Articles by Winslow, R. M.

Targeted O2 delivery by low-P50 hemoglobin: a new basis for O2 therapeutics

Amy G. Tsai,1 Kim D. Vandegriff,2 Marcos Intaglietta,1 and Robert M. Winslow1,2

1Department of Bioengineering, Bioengineering Building, University of California, San Diego, La Jolla 92093; 2Sangart Incorporated, San Diego, California 92121

Submitted 4 April 2003 ; accepted in final form 2 June 2003


    ABSTRACT
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
To assess O2 delivery to tissue by a new surface-modified, polyethylene glycol-conjugated human hemoglobin [MP4; PO2 at 50% saturation of hemoglobin (P50); 5.4 mmHg], we studied microcirculatory hemodynamics and O2 release in golden Syrian hamsters hemodiluted with MP4 or polymerized bovine hemoglobin (PolyBvHb; P50 54.2 mmHg). Comparisons were made with the animals' hemodiluted blood with a non-O2 carrying plasma expander with similar solution properties (Dextran-70). Systemic hemodynamics (arterial blood pressure and heart rate) and acid-base parameters were not correlated with microhemodynamics (arteriolar and venular diameter, red blood cell velocity, and flow). Microscopic measurements of PO2 and the O2 equilibrium curves permitted analysis of O2 release in precapillary and capillary vessels by red blood cells and plasma hemoglobin separately. No significant differences between the groups of animals with respect to arteriolar diameter, flow, or flow velocity were observed, but the functional capillary density was significantly higher in the MP4-treated animals (67%) compared with PolyBvHb-treated animals (37%; P < 0.05) or dextran-treated animals (53%). In the PolyBvHb-treated animals, predominant O2 release (both red blood cells and plasma hemoglobin) occurred in precapillary vessels, whereas in MP4 animals most of the O2 was released from both red blood cells and plasma hemoglobin in capillaries. Base excess correlated directly with capillary O2 release but not systemic O2 content or total O2 release. Higher O2 extraction of both red blood cell and plasma hemoglobin in capillaries represents a new mechanism of action of cell-free hemoglobin. High O2 affinity appears to be an important property for cell-free hemoglobin solutions.

blood substitutes; microcirculation; polyethylene glycol


ARTERIOLAR VASOCONSTRICTION limits tissue perfusion by some early-generation hemoglobin-based O2 carriers, increasing vascular resistance, which may be manifest as systemic hypertension, offsetting potential efficacy (40). Although the mechanism of vasoactivity has been disputed, one popular explanation is that nitric oxide (NO) is scavenged by cell-free hemoglobin (9), either directly in the lumen of the vessel or in the interstitial space after extravasation. We observed, however, that derivatized hemoglobins with different hypertensive effects have nearly identical NO binding constants (26). An alternative (or additional) mechanism is the involvement of autoregulation, by which vasoconstriction results from an oversupply of O2 to vascular walls, particularly in arterioles, which regulate the entry of blood into capillary networks (23). An O2 oversupply would result from facilitated diffusion of O2 as oxyhemoglobin in plasma. Oxyhemoglobin diffusion is a function of molecular size, viscosity, and O2 affinity, and manipulation of these three parameters offers strategies for potentially overcoming autoregulatory vasoconstriction. We explored these ideas in an artificial capillary system and concluded that the O2 delivery in small vessels is more similar to that of red blood cells when the hemoglobin molecules have a low PO2 at 50% saturation of hemoglobin (P50) and a large molecular volume (23). As a consequence of these studies and considerations, we have developed polyethylene glycol (PEG)-modified human hemoglobin (MP4) (36), which is now in clinical trials.

In another study, we found that the hemoglobin surface modified with PEG was remarkably efficient in its ability to protect against the ill effects of a severe hemorrhage (41). The particular PEG-hemoglobin used in that study was not well characterized, but it did not cause systemic hypertension. We hypothesized that the effectiveness of this molecule arose from a lack of vasoconstriction and consequent improved tissue perfusion, although there was no direct evidence to support that conclusion.

MP4 has been studied in its ability to resuscitate hamsters in hemorrhagic shock (38), and it also does not appear to cause hypertension in exchange transfusions in rats (36). Furthermore, it is formulated at a relatively low hemoglobin concentration (4.2 g/dl) to keep its solution properties (viscosity, oncotic pressure) within a range that is acceptable for large volume use in patients. It was therefore desired to assess the ability of this solution to delivery O2 to tissues by direct measurement. Such measurements are now available in the hamster skinfold model (30).

In the present experiments, we directly measured the delivery of O2 in the microcirculation of the hamster skinfold window by red blood cells and plasma hemoglobin separately after hemodilution to a hematocrit of 11%. MP4 was compared with polymerized bovine hemoglobin (PolyBvHb), which is very different with regard to molecular size and O2 affinity, and with Dextran-70. The microcirculation parameters, combined with the known oxygenation properties of the solutions, allow for the first time, direct calculation of O2 transport in the microcirculation.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
Experimental solutions. Dextran-70 was purchased from Braun Medical (Irvine, CA), and PolyBvHb (Oxyglobin) was purchased from Biopure (Boston, MA). MP4 is PEG-modifed human hemoglobin manufactured by Sangart (San Diego, CA), and its preparation and properties have been described previously (36). Both fluids were formulated in physiological solutions; however, the hemoglobin concentration of the PolyBvHb (13.1 g/dl) was higher than the MP4 (4.2 g/dl).

Viscosity of the solutions was measured with a cone/plate rheometer (model DV-III, Brookfield; Middleboro, MA) with the CPE-40 cone spindle at a shear rate 200/s. Colloid oncotic pressure was measured with the use of a colloid osmometer (model 4420, Wescor; Logan, UT) (34). O2 equilibrium curves of MP4 and of freshly collected hamster red blood cells were measured as described previously (37) in 100 mM phosphate buffer, pH 7.4. In the case of PolyBvHb, the published equilibrium curve (19) was digitized. All three sets of data were analyzed to determine Adair parameters with the use of MLAB software (Civilized Software; Bethesda, MD) according to previously published procedures (42). In all cases, the final saturation at the highest PO2 was adjusted to minimize the sum of squared residuals.

Animal preparations. Animal handling and care were provided in accordance with the procedures outlined in the National Institutes of Health Guide for the Care and Use of Laboratory Animals. All animal studies were approved by the Animal Subject Committee of the University of California, San Diego. The placement of dorsal skinfold window chambers in 55–65 g golden Syrian hamsters (Simonsen; Gilroy, CA) and the microcirculatory PO2 measurements have been described in detail elsewhere (32). Briefly, the animals were prepared for chamber implantation by an injection of pentobarbital sodium (50 mg/kg ip). After the hair was removed, the dorsal skin was lifted and mounted on the titanium frame of the window. Skin and subcutaneous tissue were removed until only a thin layer of retractor muscle and subcutaneous tissue remained. The exposed area was sealed with a glass coverslip incorporated into the chamber frame, and animals were allowed at least 2 days to recover. Animals were rejected from the study if there were significant signs of edema, bleeding, or unusual neovascularization. Those animals that were accepted for study were then reanesthetized for placement of polyethylene (PE) catheters in a femoral artery (PE-50) and jugular vein (PE-10). After recovery, and while awake, the animals were then progressively exchange-transfused with Dextran-70 until their hematocrit reached ~60% of baseline. A third exchange was then performed with Dextran-70, PolyBvHb, or MP4 to a final hematocrit of ~11%. Mean arterial pressure was recorded continuously over the experiment, and heart rate was determined from the pressure trace (Beckman Recorder; Spectramed pressure transducer).

Microvascular hemodynamics. At least five animals were studied in each treatment group. In each animal, at least five arterioles and venules were selected for hemodynamic measurements. To study the same microvessels throughout the experiments, we mapped the chamber vasculature as described previously (32). Before and after the hemodilution, arteriolar and venular diameter and blood flow velocity were measured online with the use of the photodiode cross-correlation technique (27). Flow (Q) in arterioles and venules was calculated as

(1)
where D is vessel diameter and V is red blood cell velocity. Because there is variation within individual animals with respect to diameter, velocity, and flow, at least five each arterioles and venules were studied. To determine the final parameters, diameter, velocity, and flow were averaged for all vessels of all animals such that the number of determinations for each was at least 25.

Microvascular PO2. PO2 measurements were made within vessels and in adjacent tissues by the Palladium-porphyrin decay methods as described previously (29). Animals received a slow intravenous injection of 15 mg/kg body wt at a concentration of 10.1 mg/ml of palladium-meso-tetra(4-carboxyphenyl) porphine (catalog no. T790, Frontier Scientific; Logan, UT). The dye was allowed to circulate for 10 min before measurements by the phosphorescence decay method. At concomitant points, arterial blood pressure, blood gases, and acid-base status were also determined (Blood Chemistry Analyzer model 248, Bayer Medical; Northwood, MA). Hematocrit in arterial blood was measured by microcentrifugation, and total and plasma hemoglobin were measured using the B-Hemoglobin instrument (HemoCue; Ångelholm, Sweden).

Functional capillary density. Functional capillary density (FCD), defined as capillary segments that have red blood cell transit in a 30-s period, were assessed in a region of ~0.5 mm2. This parameter was originally described by Lindbom and Arfors (20) and has been shown to be the best single predictor of outcome in shock in the hamster model (16). Observation of the selected regions was done systematically by displacing the microscopic field of view by one field width at a time in 10–15 successive steps. The first field was chosen close to some identifiable landmark (e.g., a vessel bifurcation) to reestablish the same fields for subsequent examination. At the magnification used, each field had 2–5 capillaries. FCD was estimated from the capillary lengths with red blood cell flow in areas composed of 10 successive defined as the total length of red blood cell-perfused capillaries divided by the area of the microscopic field of view. One value of FCD was assigned to each animal, so that the number of determinations for each group of animals was at least five.

O2 distribution. The PO2 values of systemic, arteriolar, and venular blood were used to calculate saturation from the Adair parameters and the algorithms previously described (39). The O2 content of plasma hemoglobin was calculated as

(2)
where Hbplasma is the hemoglobin concentration (in g/dl) measured in isolated plasma. Hct is the percent volume of packed red blood cells (hematocrit). YplasmaHb is the fractional saturation of the plasma hemoglobin, calculated from PO2, as described above. The coefficient 1.34 converts grams per deciliter of hemoglobin to milliliter per deciliter of O2. The O2 content of red blood cell hemoglobin was calculated as

(3)
where Hbtotal is the concentration of hemoglobin measured on an unseparated blood sample, and YRBCHb is the O2 saturation of red blood cell hemoglobin. The amount of O2 dissolved (O2dis) in plasma was calculated as

(4)
where 2.3 is the solubility coefficient for O2 in blood (in ml · dl1 · atm1) (42).

Finally, O2 release in the precapillary and capillary vessels was calculated as

(5)

(6)
where O2precap and O2cap are the quantities of O2 released in precapillary and capillary vessels, respectively, and CarteriolarO2 and CvenularO2 are the concentrations of O2 in precapillary and capillary vessels, respectively.

Statistical methods. Values are means ± SE. Differences between groups were evaluated by one-way ANOVA, with {alpha} = 0.95 and P < 0.05, indicating significance with the use of either Tukey's or Bonferroni post hoc error protection. Changes in parameters were evaluated with the use of Student's t-test.


    RESULTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
Experimental solutions. The solutions are characterized in Table 1. Dextran-70 was used as a non-O2-carrying control solution because its viscosity and oncotic pressure are nearly identical to those of MP4. The viscosities of PolyBvHb and MP4 (2.0 and 2.5 cP, respectively) are similar, as is the colloid osmotic pressure (45 and 49 mmHg, respectively). The hemoglobin concentration in the stock MP4 solution is 4.2 g/dl compared with 13.1 g/dl for PolyBvHb and 14.5 g/dl for hamster blood.


View this table:
[in this window]
[in a new window]
 
Table 1. Solution and O2 binding parameters

 

The P50 of hamster blood is slightly higher than that of human blood, and the P50 of PolyBvHb is considerably higher (Fig. 1). The degree of right shift of the PolyBvHb may be controversial; however, assignment of a P50 value to very right-shifted curves is a problem with the use of commercial measurement techniques. In these methods, the saturation, usually with room air (~150 mmHg), is set to 100%. If hemoglobin is not fully saturated at this PO2, then the P50, as measured, will be falsely low. The problem can be reduced somewhat by equilibration of the hemoglobin solution with gas with increased PO2, but this is not according to the recommendations of manufacturers of such instruments. Another way to deal with this problem is to include the final saturation as a parameter in the fit of the data to the Adair equation, as we have done in the present case. Note that the P50 of MP4 is much lower (5.4 mmHg) than either of hamster red blood cells or PolyBvHb. Note also the reduced cooperativity (N) of all three O2 carriers.



View larger version (14K):
[in this window]
[in a new window]
 
Fig. 1. O2 equilibrium curves for polyethylene glycol (PEG)-conjugated human hemoglobin (MP4), hamster red blood cells, and polymerized bovine hemoglobin (PolyBvHb). Measurements were made at 37°C in 100 mM phosphate buffer, pH 7.4.

 

Exchange transfusions. Five animals (55–65 g body wt) in each experimental group entered into the hemodilution and exchange-transfusion protocol, and all of them tolerated the experiment without any visible discomfort. The hematological changes are shown in Table 2. The MP4 exchange resulted in a plasma hemoglobin level of 1.12 ± 0.03 g/dl, which increased the total hemoglobin in blood (RBCs + MP4) to 4.80 ± 0.12 g/dl. Because the stock PolyBvHb concentration is much higher than that of MP4 (see Table 1), the post-exchange plasma hemoglobin in these animals was 3.74 ± 0.29 g/dl and the total hemoglobin (RBCs + PolyBvHb) was 6.70 ± 0.25 g/dl. The dextran-treated animals, as expected, had the lowest total hemoglobin, 3.44 ± 0.11 g/dl. Although the mean initial (baseline) hematocrit in the MP4 group was slightly higher compared with the Dextran-70-treated animals (P < 0.02), the hematocrit values in the various groups were not significantly different after hemodilution. Blood viscosity was not measured after hemodilution; however, because the main determinant of viscosity is hematocrit, and because the solutions are very well matched in this property (Table 1), there would be expected to be little or no difference between groups after hemodilution.


View this table:
[in this window]
[in a new window]
 
Table 2. Hematologic parameters after hemodilution

 

Blood gases and acid base balance. After hemodilution, decreasing pH and base excess provide evidence of inadequate tissue O2 delivery, in the order of dextran > PolyBvHb > MP4 (Table 3). Increasing PO2 and decreasing PCO2, in the order dextran > PolyBvHb > MP4 are indicative of respiratory compensation, albeit inadequate in both the dextran and PolyBvHb animals. These observations indicate that the MP4 animals deal with the severe anemia most successfully, and dextran-treated animals the least, with PolyBvHb-treated animals with intermediate success.


View this table:
[in this window]
[in a new window]
 
Table 3. Blood gases and acid-base balance after hemodilution

 

Significant reductions in PO2 are observed in arterioles compared with systemic arteries in all animals. However, the arteriolar, venular, and tissue PO2 values in the PolyBvHb animals are all significantly less than those in the MP4-treated animals (P < 0.05). The arterial pH is significantly lower in dextran-treated animals compared with MP4-treated animals after hemodilution (P < 0.05). Finally, although animal variability in the baseline base excess values do not establish statistical significance, the fall in base excess in the dextran-treated animals (12.62 meq/l) is significantly greater than the fall in either MP4-(1.48 meq/l) or PolyBvHb (3.00 meq/l)-treated animals (P < 0.05).

Tissue PO2 values are all very low, as expected in these severely hemodiluted animals. However, the higher tissue PO2 in the MP4 compared with PolyBvHb animals is statistically significant (P > 0.05).

Systemic and microvascular hemodynamics. Both the MP4 and PolyBvHb animals maintained systemic mean arterial pressure; however, in the dextran-treated animals, the mean arterial pressure fell to 65% of baseline (Fig. 2). Likewise, the heart rate in both MP4 and PolyBvHb-treated animals was not different from baseline, but there was a relatively small but significant fall in heart rate in the dextran-treated animals.



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 2. Microvascular hemodynamic measurements after extreme hemodilution. For each of the treatment groups (MP4, light gray bars; PolyBvHb, dark gray bars; dextran, open bars), the hematocrit is 11.0%. Statistical comparisons are made by comparing values to baseline (*), to MP4 values (#), and to PolyBvHb values (§). MAP, mean arterial pressure; HR, heart rate; FCD, functional capillary density.

 

Arteriolar diameter diminished slightly but significantly only in the PolyBvHb-treated animals. Arteriolar flow and red blood cell flow velocity fell significantly in all groups, but there were no differences between groups. In contrast, venular diameter was significantly less in the dextran-treated animals compared with both MP4- and PolyBvHb-treated animals, but venular red blood cell velocity and flow were increased in the dextran-treated animals. Venular red blood cell velocity and flow were reduced significantly only in the PolyBvHb-treated animals.

Finally, all FCD fell in all groups, but FCD was significantly less in the PolyBvHb (36.7% of baseline) compared with MP4 (66.5% of baseline) (P < 0.05). FCD in the dextran-treated animals was intermediate (53.2%), which was significantly less than baseline, but not different from the other two groups of animals.

O2 distribution. The amount of O2 in the three spaces, red blood cells, plasma hemoglobin, and dissolved in plasma, can be calculated using the distribution of hemoglobin (Table 1), the measured PO2 (Table 3), and the hemoglobin saturation (Fig. 1). The O2 contents of these various vessel types are presented in Table 4, and the O2 release values are given in Table 5 and Fig. 3.


View this table:
[in this window]
[in a new window]
 
Table 4. Oxygen distribution after hemodilution

 

View this table:
[in this window]
[in a new window]
 
Table 5. Oxygen extraction after hemodilution

 


View larger version (15K):
[in this window]
[in a new window]
 
Fig. 3. O2 release (O2 content differences) between arterial and arteriolar blood (Precapillary) and between arteriolar and venular blood (Capillary). Solid bars represent red blood cell hemoglobin-bound O2, gray bars represent dissolved (plasma) O2, and stippled bars represent plasma hemoglobin-bound O2. *P < 0.05, statistical significance comparing MP4 with PolyBvHb. NS, not significant.

 

With regard to red blood cell O2 release, there is no statistically significant difference between the amount in precapillary vessels between MP4-, PolyBvHb-, and dextran-treated animals, although there is a trend toward a larger amount in the PolyBvHb-treated group. However, a striking feature of the data is that a large amount of cell-free hemoglobin bound O2 is released in precapillary vessels compared with the MP4-treated aimals (P < 0.001). Essentially none of the MP4-bound O2 is release in precapillary vessels, owing to the high O2 affinity of this hemoglobin and the relatively high PO2 in these vessels.

Significantly more O2 is released in capillaries compared with precapillary vessels in the MP4 animals, and significantly less O2 is released in capillaries compared with precapillary vessels in the PolyBvHb animals, respectively, and both differences are statistically significant (P < 0.001). In the dextran-treated animals, O2 release is evenly distributed between precapillary and capillary vessels.

Table 5 also presents the fractional O2 extraction values for the red blood cell, plasma hemoglobin, and plasma dissolved compartments. The values are presented for both precapillary and capillary vessels. Most interestingly, the calculations show that the O2 extraction ratio (i.e., percent of arterial O2 that is delivered) for red blood cells in the MP4 animals is 28% in precapillary vessels and 47% in capillaries. In contrast, the red blood cells of animals treated with PolyBvHb release 43% of the bound O2 in precapillary vessels, and only 14% in capillaries. In terms of overall O2 release (red cell + plasma Hb + dissolved), MP4 animals release 62% of the arterial content of O2 into capillaries, compared with 31% in precapillary vessels. In contrast, the PolyBvHb animals release 69% of their total arterial O2 content into precapillary vessels and only 31% into capillaries. In the dextran-treated animals, O2 release is about evenly distributed between precapillary and capillary vessels for red blood cells, and the contribution from dissolved O2 is negligible.

Although absolute O2 uptake (O2) across capillary networks cannot be calculated without volume flow, the microhemodynamic data (see Fig. 2) do not support the quantitative conclusion that the increased O2 extraction in MP4 animals is a result of increased capillary perfusion alone. The FCD is significantly greater in the MP4 animals compared with the PolyBvHb-treated animals (P < 0.05), but arteriolar and venular flow, although greater in the MP4-treated animals, is not statistically different from the values for PolyBvHb-treated animals.

Global O2 delivery. Base excess calculated in arterial blood was used to assess whether the microcirculatory O2 distribution is indicative of global (whole body) O2 supply. Only weak correlations were found between arterial base excess and arterial O2 content (r2 = 0.479), hematocrit (r2 = –0.275), total hemoglobin (r2 = 0.324), and plasma hemoglobin concentration (r2 = 0.196) (see Fig. 4). In contrast, the correlation between base excess and capillary O2 release is 0.976, suggesting that this parameter is indicative of total body O2 supply (see Fig. 5).



View larger version (17K):
[in this window]
[in a new window]
 
Fig. 4. O2 content vs. base excess. Note that of the parameters examined, only capillary O2 release significantly correlates with base excess. Hct, hematocrit.

 


View larger version (13K):
[in this window]
[in a new window]
 
Fig. 5. Relationship among base excess, arterial O2 content, and capillary O2 release. Note that base excess, a measure of tissue perfusion and O2 sufficiency, does not correlate with total O2 content of arterial blood, but it is highly correlated with capillary O2 release.

 


    DISCUSSION
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
In animals that were hemodiluted with MP4, 62% of the total arterial O2 content is released in capillaries. This is in distinct contrast to animals that were hemodiluted to the same degree with polymerized bovine hemoglobin, in which only 31% of the arterial O2 content is released in capillaries, and to animals that were hemodiluted with Dextran-70, in which 40% of the arterial O2 is released in capillaries. That this release of O2 in capillaries is effective in satisfying tissue O2 demands is supported by the strong correlation of capillary O2 release with arterial base excess, a measure of global tissue oxygenation.

Total capillary O2 delivery is 3.99 ml/dl with plasma hemoglobin concentration only 1.12 g/dl indicates that MP4 is highly efficient in O2 transport. This is in contrast to the PolyBvHb-treated animals, in which the plasma hemoglobin concentration is 3.74 g/dl and capillary O2 delivery is 2.35 ml/dl. On a per-gram-of-hemoglobin basis, this represents an increase in efficiency of more than fivefold. The explanation for this remarkable observation is that in the case of MP4, not only is O2 delivered to capillaries by the plasma hemoglobin itself, but also more red blood cell hemoglobin-bound O2 is released in capillaries as well. Thus, in comparing the two cell-free O2 carriers, it appears that the most likely explanation is that O2 is released from precapillary vessels prematurely and that this O2 is "lost" from delivery to capillaries. This concept is consistent with our view that lowered O2 affinity of cell-free hemoglobin promotes facilitated diffusion and loss from vessels (23).

An additional factor that promotes O2 release in capillaries is FCD. In the MP4-treated animals, FCD is 67% of baseline, whereas in the PolyBvHb-treated animals, FCD is reduced to 37% (P < 0.05). The FCD value for the dextran-treated animals (53%) is intermediate between the other two groups and is not significantly different from either. We propose that high precapillary O2 loss stimulates microvascular arteriolar vasoconstriction, elevating systemic pressure proximal to the constriction but reducing pressure distal to it. This would result in depressurization of capillaries, leading to reduced red blood cell flow (i.e., loss of FCD), lowered hematocrit, and consequent reduced red blood cell O2 delivery to the tissues served by the capillary network. The data from our experiments do not prove this mechanism, but the reduction in vessel width required to have this effect would be too small to detect by current methods.

High precapillary O2 loss was observed with the use of microelectrode measurements in rats and hamsters (7) and has been confirmed by more recent studies (15, 31, 33) using sophisticated microscopic PO2 measurements. Precapillary PO2 in the range of 20–40 mmHg (present study) suggested that intravascular PO2 could be a sensitive effector of local vasoconstriction, as has been suggested by Guyton (10) for precapillary sphincters, and which would apply to arterioles as well. Studies (20, 21) in the rabbit tenuissimus microcirculation showed clearly that FCD is inversely related to PO2.

The participation of cell-free hemoglobin in facilitated diffusive O2 delivery has been studied by many investigators. As early as 1960, Scholander (28) showed that the rate of diffusion of O2 through a solution of hemoglobin could be increased as much as eightfold compared with plasma and that this rate could be modulated by hemoglobin concentration and O2 affinity. More recent measurements have confirmed these findings (3, 4). Hemoglobin, free in the plasma space, can greatly increase the supply of O2 to vessel walls (8, 13), and some measurements have been made with modified hemoglobin solutions and encapsulated hemoglobin (5, 24). Most of these measurements have been made in static solutions, a very simple system compared with flow through small vessels, which is made complex because of mixing, the dependency of O2 release on flow rate, and the presence of red blood cells in the solution. However, direct measurements in vitro in artificial capillaries show that cell-free hemoglobin is more efficient than red blood cells in the uptake and release of O2 (2, 17, 23, 25), and PolyBvHb increases the lung-diffusing capacity in humans, presumably by a similar mechanism (14). However, despite this body of evidence, experiments designed to show more efficient oxygenation of muscle tissue after replacement of red blood cells with cell-free hemoglobin have failed to do so (1, 12). Our data suggest that in these cases the bulk of O2 delivery occurs before the capillaries, thus engaging autoregulatory vasoconstriction, with the concomitant increase of O2 consumption by the constricting vessel wall (43). This interpretation is also consistent with the observation that when {alpha}{alpha}-crosslinked hemoglobin was administered to animals and humans (11, 40) the increased O2 capacity was offset by vasoconstriction to the detriment of tissue oxygenation.

Given the proposed sequence of events that follow introduction of hemoglobin into the plasma space, the critical parameters of a successful cell-free hemoglobin-based O2 therapeutic become immediately apparent: 1) increase hemoglobin affinity for O2, and 2) reduce the diffusivity of the molecule by increasing its size and viscosity, according to the Stokes-Einstein law

(7)
where DHbO2 is the diffusion coefficient for cell-free hemoglobin, K is Boltzman's constant, T is absolute temperature, {eta} is viscosity, and r is molecular radius. MP4 has increased molecular radius and viscosity compared with early generation products, reduced DHbO2, and the data in the present experiments indicate that it permits high FCD, reduced vasoactivity, and effective oxygenation of capillaries.

On the basis of ex vivo measurements of aortic ring constriction by hemoglobin, it has been tempting to explain hemoglobin-induced vasoconstriction on scavenging of NO, and hemoglobin mutants with decreased NO affinity are less hypertensive than native hemoglobin (6, 18). However, whereas constriction of either large (arterial) or small (arteriolar) vessels may raise systemic blood pressure, it is arteriolar vasoconstriction that limits capillary perfusion.

Regulation of capillary blood flow, the protection of hemoglobin within red blood cells, and the low solubility of O2 in plasma are biological, chemical, and physical features that are integrated into a system of O2 delivery, which is the product of millions of years of evolution. The movement of O2 out of the vessel necessitates overcoming barriers (35), which include limited diffusion within the red blood cell, diffusion through unstirred plasma surrounding the red blood cell, and diffusion through a layer of plasma with a variable thickness that depends on the size of the vessel and its flow characteristics. Ultimately, the release of O2 from the vessel wall is a function of the diffusion distance through the plasma layer at the vessel wall (22), the diffusion constant for O2, its solubility, and the gradient of O2 concentration at the vessel wall. These factors combine to keep O2 within precapillary vessels. The essential problem for complex organisms, such as mammals, is to conduct O2 from the lung to tissue with minimal losses, so that the bulk of the O2 can be released in capillaries, rather than in tissues that already have sufficient O2 supply. The introduction of highly diffusible cell-free hemoglobin defeats these mechanisms and leads to accelerated release of O2 before entering the capillaries, triggering autoregulatory protective mechanisms aimed at decreasing the supply of O2 to highly metabolic tissues. Property selections of cell-free hemoglobin that retard O2 release before entry into capillaries can potentially solve this problem.

Finally, it should be noted that arterial O2 content, which in the case of red blood cell transfusions is represented by simple measurement of total hemoglobin concentration or hematocrit, does not correlate with tissue oxygenation, at least as base excess is an indicator (see Fig. 4). This has the important clinical implication that hemoglobin and hematocrit cannot reliably be used as surrogates for O2 delivery to tissues as has been the practice for centuries. Instead, when patients are treated with cell-free O2 carriers with properties such as those of MP4, other, and possibly novel, methods of assessing O2 transport status will be required.


    DISCLOSURES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
This study was supported by National Institutes of Health Bioengineering Partnership Grant R24 64395 and Grants R01-40696, R01-62354, and R01-62318.

R. M. Winslow is President, CEO, and Board Chairman and M. Intaglietta is a member of the Board of Directors of Sangart. K. D. Vandegriff holds Sangart employee stock options.


    FOOTNOTES
 

Address for reprint requests and other correspondence: R. M. Winslow, Sangart, Inc., 11189 Sorrento Valley Rd., Suite 104, San Diego, CA 92121 (E-mail: rwinslow{at}sangart.com).

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 

  1. Biro G, Anderson P, Curtis S, and Cain S. Stroma-free hemoglobin: its presence in plasma does not improve oxygen supply to the resting hindlimb vascular bed of hemodiluted dogs. Can J Physiol Pharmacol 69: 1656–1662, 1991.[Web of Science][Medline]
  2. Boland E, Nair P, Lemon D, Olson J, and Hellums J. An in vitro capillary system for studies on microcirculatory O2 transport. J Appl Physiol 62: 791–797, 1987.[Abstract/Free Full Text]
  3. Bouwer S, Hoofd L, and Kreuzer F. Diffusion coefficients of oxygen and hemoglobin measured by facilitated oxygen diffusion through hemoglobin solutions. Biochim Biophys Acta 1338: 127–136, 1997.[Medline]
  4. Bouwer ST, Hoofd L, and Kreuzer F. Reaction rates of oxygen with hemoglobin measured by non-equilibrium facilitated diffusion through hemoglobin solutions. Biochim Biophys Acta 1525: 108–117, 2001.[Medline]
  5. Budhiraja V and Hellums J. Effect of hemoglobin polymerization on oxygen transport in hemoglobin solutions. Microvasc Res 64: 220–233, 2002.[Web of Science][Medline]
  6. Doherty DH, Doyle MP, Curry SR, Vali RJ, Fattor TJ, Olson JS, and Lemon DD. Rate of reaction with nitric oxide determines the hypertensive effect of cell-free hemoglobin. Nat Biotechnol 16: 672–676, 1998.[Web of Science][Medline]
  7. Duling BR and Berne RM. Longidudinal gradients in periarteriolar oxygen tension. A possible mechanism for the participation of oxygen in local regulation of blood flow. Circ Res 27: 669–678, 1970.[Abstract/Free Full Text]
  8. Federspiel WJ and Popel AS. A theoretical analysis of the effect of the particulate nature of blood on oxygen release in capillaries. Microvasc Res 32: 164–189, 1986.[Web of Science][Medline]
  9. Gibson QH and Roughton FJW. The kinetics and equilibria of the reactions of nitric oxide with sheep hemoglobin. J Appl Physiol 136: 123–134, 1956.
  10. Guyton A. Local control of blood flow by the tissues, and humoral regulation. In: Textbook of Medical Physiology. Philadelphia, PA: Saunders, 1996, p. 199–207.
  11. Hess J, Macdonald V, Murray A, Coppes V, and Gomez C. Pulmonary and systemic hypertension after hemoglobin administration (Abstract). Blood 78: 356A, 1991.
  12. Hogan M, Kurdak S, Richardson R, and Wagner P. Partial substitution of red blood cells with free hemoglobin does not improve maximal O2 uptake of working in situ dog muscle. Adv Exp Med Biol 361: 375–378, 1994.[Medline]
  13. Homer L, Weathersby P, and Kiesow L. Oxygen gradients between red blood cells in the microcirculation. Microvasc Res 22: 308–323, 1981.[Web of Science][Medline]
  14. Hughes GS, Antal EJ, Locker PK, Francom SF, Adams WJ, and Jacobs EE Jr. Physiology and pharmacokinetics of a novel hemoglobin-based oxygen carrier in humans. Crit Care Med 24: 756–764, 1996.[Web of Science][Medline]
  15. Intaglietta M, Johnson P, and Winslow R. Microvascular and tissue oxygen distribution. Cardiovasc Res 32: 632–643, 1996.[Web of Science][Medline]
  16. Kerger H, Saltzman DJ, Menger MD, Messmer K, and Intaglietta M. Systemic and subcutaneous microvascular PO2 dissociation during 4-h hemorrhagic shock in conscious hamsters. Am J Physiol Heart Circ Physiol 270: H827–H836, 1996.[Abstract/Free Full Text]
  17. Lemon D, Nair P, Boland E, Olson J, and Hellums J. Physiological factors affecting O2 transport by hemoglobin in an in vitro capillary system. J Appl Physiol 62: 798–806, 1987.[Abstract/Free Full Text]
  18. Lemon DD, Doherty DH, Curry SR, Mathews AJ, Doyle MP, Fattor TJ, and Olson JS. Control of the nitric oxide-scavenging activity of hemoglobin (Abstract). Art Cells, Blood Subs, Immob Biotech 24: 378, 1996.
  19. Light WR, Jacobs EE, Rentko VT, Gawryl MS, and Hughes GS. Use of HBOC-201 as an oxygen therapeutic in the preclinical and clinical settings. In: Red Blood Cell Substitutes, edited by Rudolph AS, Rabinovici R, and Feuerstein GZ. New York: Dekker, 1998, p. 421–436.
  20. Lindbom L and Arfors KE. Mechanism and site of control for variation in the number of perfused capillaries in skeletal muscle. Int J Microcirc Clin Exp 4: 121–127, 1985.[Web of Science][Medline]
  21. Lindbom L, Tuma R, and Arfors K. Influence of oxygen on perfused capillary density and capillary red cell velocity in rabbit skeletal muscle. Microvasc Res 19: 197–208, 1980.[Web of Science][Medline]
  22. Maeda N. Erythrocyte rheology in microcirculation. Jpn J Physiol 46: 1–14, 1996.[Web of Science][Medline]
  23. McCarthy MR, Vandegriff KD, and Winslow RM. The role of facilitated diffusion in oxygen transport by cell-free hemoglobin: implications for the design of hemoglobin-based oxygen carriers. Biophys Chem 92: 103–117, 2001.[Web of Science][Medline]
  24. Nishide H, Chen XS, and Tsuchida E. Facilitated oxygen transport with modified and encapsulated hemoglobins across non-flowing solution membrane. Artif Cells Blood Substit Immobil Biotechnol 25: 335–346, 1997.[Web of Science][Medline]
  25. Page TC, Light WR, McKay CB, and Hellums JD. Oxygen transport by erythrocyte/hemoglobin solution mixtures in an in vitro capillary as a model of hemoglobin-based oxygen carrier performance. Microvasc Res 55: 54–64, 1998.[Web of Science][Medline]
  26. Rohlfs RJ, Bruner E, Chiu A, Gonzales A, Gonzales ML, Magde D, Magde MD, Vandegriff KD, and Winslow RM. Arterial blood pressure responses to cell-free hemoglobin solutions and the reaction with nitric oxide. J Biol Chem 273: 12128–12134, 1998.[Abstract/Free Full Text]
  27. Sakai H, Takeoka S, Wettstein R, Tsai A, Intaglietta M, and Tsuchica E. Systemic and microvascular responses to hemorrhagic shock and resuscitation with Hb vesicles. Am J Physiol Heart Circ Physiol 283: H1191–H1199, 2002.[Abstract/Free Full Text]
  28. Scholander P. Oxygen transport through hemoglobin solutions. Science 131: 585–590, 1960.[Free Full Text]
  29. Torres F and Intaglietta M. Microvessel PO2 mesurements by phosphorescence decay method. Am J Physiol Heart Circ Physiol 265: H1434–H1438, 1993.[Abstract/Free Full Text]
  30. TorresFilho I, Kerger H, and Intaglietta M. PO2 measurements in arteriolar networks. Microvasc Res 51: 202–212, 1996.[Web of Science][Medline]
  31. Tsai A, Kerger H, and Intaglietta M. Microcirculatory Consequences of Blood Substitution, edited by Winslow R, Vandegriff K, and Intaglietta M. New York: Birkhauser, 1995.
  32. Tsai AG. Influence of cell-free Hb on local tissue perfusion and oxygenation in acute anemia after isovolemic hemodilution. Transfusion 41: 1–10, 2001.[Web of Science][Medline]
  33. Tsai AG, Friesenecker B, Mazzoni MC, Kerger H, Buerk DG, Johnson PC, and Intaglietta M. Microvascular and tissue oxygen gradients in the rat mesentery. Proc Natl Acad Sci USA 95: 6590–6595, 1998.[Abstract/Free Full Text]
  34. Vandegriff K, McCarthy M, Rohlfs R, and Winslow R. Colloid osmotic properties of modified hemoglobins: chemically cross-linked versus polyethylene glycol surface-conjugated. Biophys Chem 69: 23–30, 1997.[Web of Science][Medline]
  35. Vandegriff K and Olson J. The kinetics of O2 release by human red blood cells in the presenc of external sodium dithionite. J Biol Chem 259: 12609–12618, 1984.[Abstract/Free Full Text]
  36. Vandegriff KD, Malavalli A, Wooldridge J, Lohman J, and Winslow RM. MP4, a new non-vasoactive polyethytlene glycol-hemoglobin conjugate. Transfusion 43: 509–516, 2003.[Web of Science][Medline]
  37. Vandegriff KD, Rohlfs RJ, Magde MD, and Winslow RM. Hemoglobin-oxygen equilibrium curves mesured during enzymatic oxygen consumption. Anal Biochem 256: 107–116, 1998.[Web of Science][Medline]
  38. Wettstein R, Tsai AG, Erni D, Winslow RM, and Intaglietta M. Resuscitation with polyethylene glycol-modified human hemoglobin improves microcirculatory blood flow and tissue oxygenation after hemorrhagic shock in awake hamsters. Crit Care Med 31: 1824–1830, 2003.[Web of Science][Medline]
  39. Winslow R, Samaja M, Winslow N, Rossi-Bernardi L, and Shrager R. Simulation of the continuous O2 equilibrium curve over the physiologic range of pH, 2,3-diphosphoglycerate, and PCO2. J Appl Physiol 54: 524–529, 1983.[Abstract/Free Full Text]
  40. Winslow RM. {alpha}{alpha}-Crosslinked hemoglobin: was failure predicted by preclinical testing? Vox Sang 79: 1–20, 2000.[Web of Science][Medline]
  41. Winslow RM, Gonzales A, Gonzales M, Magde M, McCarthy M, Rohlfs RJ, and Vandegriff KD. Vascular resistance and the efficacy of red cell substitutes in a rat hemorrhage model. J Appl Physiol 85: 993–1003, 1998.[Abstract/Free Full Text]
  42. Winslow RM, Swenberg M, Berger R, Shrager R, Luzzana M, and Samaja M. Oxygen equilibrium curve of normal human blood and its evaluation by Adair's equation. J Biol Chem 252: 2331–2337, 1977.[Abstract/Free Full Text]
  43. Ye JM, Colquhoun EQ, and Clark MG. A comparison of vasopressin and noradrenaline on oxygen uptake by perfused rat hind limb, intestine, and mesentery arcade suggests that it is in part due to contractile work by blood vessels. Gen Pharmacol 21: 805–810, 1990.[Web of Science][Medline]



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
P. Cabrales, G. Sun, Y. Zhou, D. R. Harris, A. G. Tsai, M. Intaglietta, and A. F. Palmer
Effects of the molecular mass of tense-state polymerized bovine hemoglobin on blood pressure and vasoconstriction
J Appl Physiol, November 1, 2009; 107(5): 1548 - 1558.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. A. Plock, N. Rafatmehr, D. Sinovcic, J. Schnider, H. Sakai, E. Tsuchida, A. Banic, and D. Erni
Hemoglobin vesicles improve wound healing and tissue survival in critically ischemic skin in mice
Am J Physiol Heart Circ Physiol, September 1, 2009; 297(3): H905 - H910.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
T. Mito, M. Nemoto, H. Kwansa, K. Sampei, M. Habeeb, S. J. Murphy, E. Bucci, and R. C. Koehler
Decreased Damage From Transient Focal Cerebral Ischemia by Transfusion of Zero-Link Hemoglobin Polymers in Mouse
Stroke, January 1, 2009; 40(1): 278 - 284.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Cell Mol. Bio.Home page
P. Cabrales, A. G. Tsai, and M. Intaglietta
Modulation of Perfusion and Oxygenation by Red Blood Cell Oxygen Affinity during Acute Anemia
Am. J. Respir. Cell Mol. Biol., March 1, 2008; 38(3): 354 - 361.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales
Effects of erythrocyte flexibility on microvascular perfusion and oxygenation during acute anemia
Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H1206 - H1215.
[Abstract] [Full Text] [PDF]


Home page
BloodHome page
A. F. Palmer
Molecular volume and HBOC-induced vasoconstriction
Blood, November 15, 2006; 108(10): 3231 - 3232.
[Full Text] [PDF]


Home page
BloodHome page
A. G. Tsai, P. Cabrales, B. N. Manjula, S. A. Acharya, R. M. Winslow, and M. Intaglietta
Dissociation of local nitric oxide concentration and vasoconstriction in the presence of cell-free hemoglobin oxygen carriers
Blood, November 15, 2006; 108(10): 3603 - 3610.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales and A. G. Tsai
Plasma viscosity regulates systemic and microvascular perfusion during acute extreme anemic conditions
Am J Physiol Heart Circ Physiol, November 1, 2006; 291(5): H2445 - H2452.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, J. Martini, M. Intaglietta, and A. G. Tsai
Blood viscosity maintains microvascular conditions during normovolemic anemia independent of blood oxygen-carrying capacity
Am J Physiol Heart Circ Physiol, August 1, 2006; 291(2): H581 - H590.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Nemoto, T. Mito, W. S Brinigar, C. Fronticelli, and R. C. Koehler
Salvage of focal cerebral ischemic damage by transfusion of high O2-affinity recombinant hemoglobin polymers in mouse
J Appl Physiol, May 1, 2006; 100(5): 1688 - 1691.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
X. Qin, H. Kwansa, E. Bucci, R. J. Roman, and R. C. Koehler
Role of 20-HETE in the pial arteriolar constrictor response to decreased hematocrit after exchange transfusion of cell-free polymeric hemoglobin
J Appl Physiol, January 1, 2006; 100(1): 336 - 342.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, A. G. Tsai, R. M. Winslow, and M. Intaglietta
Extreme hemodilution with PEG-hemoglobin vs. PEG-albumin
Am J Physiol Heart Circ Physiol, December 1, 2005; 289(6): H2392 - H2400.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Sampei, J. A. Ulatowski, Y. Asano, H. Kwansa, E. Bucci, and R. C. Koehler
Role of nitric oxide scavenging in vascular response to cell-free hemoglobin transfusion
Am J Physiol Heart Circ Physiol, September 1, 2005; 289(3): H1191 - H1201.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. Sakai, P. Cabrales, A. G. Tsai, E. Tsuchida, and M. Intaglietta
Oxygen release from low and normal P50 Hb vesicles in transiently occluded arterioles of the hamster window model
Am J Physiol Heart Circ Physiol, June 1, 2005; 288(6): H2897 - H2903.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, A. G. Tsai, R. M. Winslow, and M. Intaglietta
Effects of extreme hemodilution with hemoglobin-based O2 carriers on microvascular pressure
Am J Physiol Heart Circ Physiol, May 1, 2005; 288(5): H2146 - H2153.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, H. Sakai, A. G. Tsai, S. Takeoka, E. Tsuchida, and M. Intaglietta
Oxygen transport by low and normal oxygen affinity hemoglobin vesicles in extreme hemodilution
Am J Physiol Heart Circ Physiol, April 1, 2005; 288(4): H1885 - H1892.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. D. Baines and P. Ho
20-HETE-mediated vasoconstriction by hemoglobin-O2 carrier in Sprague-Dawley but not Wistar rats
J Appl Physiol, March 1, 2005; 98(3): 772 - 779.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, A. G. Tsai, and M. Intaglietta
Increased tissue PO2 and decreased O2 delivery and consumption after 80% exchange transfusion with polymerized hemoglobin
Am J Physiol Heart Circ Physiol, December 1, 2004; 287(6): H2825 - H2833.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. O. Dull, B. J. DeWitt, R. Dinavahi, L. Schwartz, C. Hubert, N. Pace, and C. Fronticelli
Quantitative assessment of hemoglobin-induced endothelial barrier dysfunction
J Appl Physiol, November 1, 2004; 97(5): 1930 - 1937.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, N. D. Kanika, B. N. Manjula, A. G. Tsai, S. A. Acharya, and M. Intaglietta
Microvascular PO2 during extreme hemodilution with hemoglobin site specifically PEGylated at Cys-93({beta}) in hamster window chamber
Am J Physiol Heart Circ Physiol, October 1, 2004; 287(4): H1609 - H1617.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. Friesenecker, A. G. Tsai, M. W. Dunser, A. J. Mayr, J. Martini, H. Knotzer, W. Hasibeder, and M. Intaglietta
Oxygen distribution in microcirculation after arginine vasopressin-induced arteriolar vasoconstriction
Am J Physiol Heart Circ Physiol, October 1, 2004; 287(4): H1792 - H1800.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
P. Cabrales, A. G. Tsai, J. A. Frangos, J. C. Briceno, and M. Intaglietta
Oxygen delivery and consumption in the microcirculation after extreme hemodilution with perfluorocarbons
Am J Physiol Heart Circ Physiol, July 1, 2004; 287(1): H320 - H330.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Drobin, B. T. Kjellstrom, E. Malm, A. Malavalli, J. Lohman, K. D. Vandegriff, M. A. Young, and R. M. Winslow
Hemodynamic response and oxygen transport in pigs resuscitated with maleimide-polyethylene glycol-modified hemoglobin (MP4)
J Appl Physiol, May 1, 2004; 96(5): 1843 - 1853.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
E. L. Bloomfield, B. J. Leone, and A. Schubert
The Safety of Hemoglobin Blood Substitutes * Response
Anesth. Analg., April 1, 2004; 98(4): 1193 - 1193.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
285/4/H1411    most recent
00307.2003v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (60)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsai, A. G.
Right arrow Articles by Winslow, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsai, A. G.
Right arrow Articles by Winslow, R. M.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2003 by the American Physiological Society.