Am J Physiol Heart Circ Physiol 285: H1966-H1975, 2003; doi:10.1152/ajpheart.00357.2003
0363-6135/03 $5.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (22)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lu, X.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lu, X.
Right arrow Articles by Kassab, G. S.

Shear modulus of porcine coronary artery: contributions of media and adventitia

X. Lu,1 J. Yang,2 J. B. Zhao,2 H. Gregersen,2 and G. S. Kassab1

1Department of Biomedical Engineering, University of California, Irvine, California 92697; and 2Center for Sensory-Motor Interaction, Aalborg University, and Department A, Aalborg Hospital, 9000 Aalborg, Denmark

Submitted 17 April 2003 ; accepted in final form 14 June 2003


    ABSTRACT
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
The epicardial coronary arteries experience significant torsion in the axial direction due to changes in the shape of the heart during the cardiac cycle. The objective of this study was to determine the torsional mechanical properties of the coronary arteries under various circumferential and longitudinal loadings. The coronary artery was treated as a two-layer composite vessel consisting of intima-medial and adventitial layers, and the shear modulus of each layer was determined. Eight porcine hearts were obtained at a local abattoir, and their right coronary and left anterior descending arteries were isolated and tested in vitro with a triaxial torsion machine (inflation, longitudinal stretch, and circumferential twist). After the intact vessel was tested, the adventitia was dissected away, leaving an intact media that was then tested under identical triaxial loading conditions. We proposed a biomechanical analysis to compute the shear modulus of the adventitia from the measured shear moduli of the intact vessel and the media. To validate our predictions, we used four additional hearts in which the shear modulus of the adventitia was measured after dissection of media. Our results show that the shear modulus does not depend on the shear stress or strain but varies linearly with circumferential and longitudinal stresses and in a nonlinear way with the corresponding strains. Furthermore, we found that the shear modulus of the adventitia is larger than that of the intact vessel, which is larger than the vessel media. These results may have important implications for baroreceptor sensitivity, circulation of the vasa vasorum, and coronary dissection.

torsion; two-layer model; polar moment of inertia; triaxial torsion machine


THE BLOOD VESSEL WALL IS EXPOSED to two distinct hemodynamic forces: 1) shear stress, the frictional force generated by blood flow, and 2) tensile stress or strain due to vessel wall distension by blood pressure. On the surface of the heart, however, the large coronary arteries experience these mechanical forces as well as marked extensions and torsion in the axial direction due to changes in the shape and size of the heart during the cardiac cycle (4, 12, 19). Therefore, the study of the shear properties of these vessels is a significant aspect of coronary physiology and pathophysiology. Although there have been a number of studies on the passive mechanical properties of the coronary arteries in the circumferential and longitudinal directions (see review in Ref. 10), there have been no studies on the shear properties of these vessels. One of the goals of the present study was to fill this gap. In the process, we determined the dependence of the shear modulus on pressure, circumferential stress, and longitudinal stretch and stress.

The second goal of this study was to model the coronary blood vessel wall as a two-layer composite (intima-medial and adventitial layers). Each layer has its own zero-stress state and its own elastic constants. We tested the coronary artery as an intact vessel followed by dissection of either the adventitia or the media. A biomechanical analysis was proposed to compute the shear modulus of the adventitia from that of the intact vessel and media or the media from the intact vessel and adventitia. We found a simple relationship between the modulus of the intact vessel and that of its two layers. The results are discussed along with the assumptions and implications.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
Triaxial torsion machine. Figure 1 shows a schematic of the triaxial machine. The arterial specimen is mounted on the cannula horizontally on both ends. The cannula on the left is connected to the torque transducer as shown in Fig. 1. The right cannula is connected to a load cell (Sensotec model; Sensotec error at 0.15–0.25% at full scale), and the load cell is fixed with a servo motor (type SDS 601, Parker Hannifin) that twists the specimen at an angle {theta}. The organ bath chamber is designed to keep the specimen immersed in the physiological solution and to eliminate any friction between the cannulas and the wall of chamber. The cannulas are made to pass through the holes on the side walls of the chamber, and then a circulative pump is used to maintain the volume of the solution in the chamber. The right cannula is also connected with a pressure transducer (Summit disposable pressure transducer, Baxter Healthcare; error of ±2% at full scale) through a Y tube. A pressure regulator is used to control the luminal pressure in the arterial specimen. The torque transducer on the left and the rotation motor on the right are mounted on the linear stage (Daedal positioning table, type 402006 LNMS D L2 C2 M1, Parker Hannifin). The motor for linear motion (type SDL 603, Parker Hannifin) drives the stage. The torque transducer is made of a flexure pivot bearing (model 6008-800, Lucas Aerospace) and an encoder (model CP200 sin/cos, Computer Optical Products; error of ±5%). The flexure pivot bearing and the encoder are fixed on a pivot that is connected to the left cannula. The flexure pivot bearing shows a linear relation between twist angle and applied torque. The encoder can detect very small changes of angle. The result of calibration of the torque transducer shows that one count of the encoder is equal to 0.393 µN · m.



View larger version (21K):
[in this window]
[in a new window]
 
Fig. 1. A schematic of the triaxial machine.

 

Heart preparation. Twelve hearts of Danish Landrace-Yorkshire pigs with body weight in the range of 90–95 kg were obtained at a local abattoir. The hearts were transported to the laboratory in 4°C Krebs solution within 45 min after the animal was killed. A 20- to 30-mm segment of the left anterior descending artery (LAD) and of the right coronary artery (RCA) were dissected carefully from their emergence at aortic ostia, every bifurcation was identified, and each branch was ligated with 6-0 suture. The anterior surfaces of the LAD and RCA segments were marked with water-resistant ink. The loose connective tissue around the segments was dissected carefully in cold Krebs solution.

Two rings (length 1–2 mm) were cut each from proximal and distal LAD and RCA. The cross section of rings was videotaped to measure the internal and external circumference and wall area in the no-load (zero transmural pressure) state. To obtain the zero-stress state, all rings were cut radially at the anterior surface. The digital photographs of all sections at the zero-stress state were saved in a computer and measured with Sigma image software.

Mechanical test. The remaining segment (15–20 mm) was mounted on the cannulas of the triaxial machine as shown in Fig. 1. Microbeads (stainless steel, 60–100 µm in diameter) were dispersed on the outer surface of the segment, which were videotaped during triaxial testing to measure displacement and compute strain. The segment was immersed in Krebs solution in the organ bath, which was aerated with 95% O2-5% CO2 at room temperature (~22°C). The segment was preconditioned several times to obtain reproducible mechanical data. Briefly, preconditioning was performed as follows. The pressure was set at zero, the axial stretch ratio was ramped from 1 to 1.4 for four cycles, the stretch ratio was then fixed at 1.4, and the arteries were ramped from 0 to 18.7 kPa (140 mmHg) for four cycles.

In the protocol of triaxial measurements, the longitudinal stretch ratio ({lambda}z) was varied from 1 to 1.4 in increments of 0.1. The transmural pressure (P) was set at 0, 3, 5, 8, 10.7, 13.3, 16, and 18.7 kPa at every {lambda}z. At each {lambda}z and pressure, a ramp of twist was performed from 0° to –25° and from 0° to 25°. For example, at {lambda}z = 1.2 and P = 8 kPa (60 mmHg), the twist angle was varied between –25° and 25°; however, when the stretch ratio was small ({lambda}z <= 1.2), the segment became curved at higher pressures (>=10.7 kPa). Curved segments were not included in the analysis. The vessel was also preconditioned to twist before measurements.

The segment was removed from the triaxial machine and then transferred to a dish in cold Krebs solution. In eight hearts, the adventitia of the arterial segments was carefully dissected away from the media at the external elastic laminae with the aid of a stereomicroscope. The intima-medial layer of the arterial segments remained intact and was tested in the triaxial machine according to the same protocol used for the intact wall. In an additional four hearts, the vessel segment was inverted inside out and the media was dissected away, leaving the adventitia intact. The adventitia was then reinverted and tested in the triaxial machine with the protocol described above.

Histological preparation. The tissue specimens were fixed in formalin solution over 24 h and embedded in paraffin. Five-micrometer-thick sections were cut and stained with hematoxylin and eosin to examine the changes in the media or adventitia due to dissection of the adjacent layer. The thickness of media both in the intact arterial rings and in the rings after dissection was measured.

Biomechanical principles. The coronary artery is considered to be a two-layer cylinder. Because the intima is relatively thin in the normal artery, the intima-media is considered as the inner layer and the adventitia as the outer layer. Initially, the arterial wall is considered to be a homogeneous material so that we may obtain an "apparent" shear modulus. The artery is subjected to a transmural pressure (Pi), a longitudinal force (F{lambda}), and a torque (T). The radii of the inner boundary of the intima, the interface of the media and adventitia, and the outer boundary of the adventitia are denoted by ri, rm, and ra, respectively, as shown in Fig. 2. We consider a vessel segment of length L undergoing a twist angle {theta} and an angle of twist per unit length {theta}/L. The average shear stress in the vessel wall is {sigma}z{theta} for the intact artery. In the present experiments, we found that T is linearly proportional to {theta}/L in the range of interest. Hence, {sigma}z{theta} is linearly proportional to {theta}/L in this range. Because the shear strain (ez{theta}) is, by definition, ez{theta} = r{theta}/2L, the linearity implies that

(1)
where G is the shear modulus of elasticity of the intact arterial wall. The torque is given by an integral of the product of the average shear stress and the moment arm and the wall area as

(2a)
where J is the polar moment of inertia of the intact vessel given by

(2b)
Finally, we obtain the desired relationship between the torque and the shear modulus as given by

(3)



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 2. Two-layer model of coronary artery that is exposed to transmural pressure (Pi), axial tension force (F{lambda}), and twist torque (T). L, vessel segment length; ra, rm, ri, radii of outer boundary of adventitia, interface of media and adventitia, and intima; ro, outer radius at loaded state; {theta}, twist angle.

 

To extend this analysis to a two-layer model, we assume that there is no slip between the medial and adventitial layers during torsion. This implies that the two layers have the same twist angle ({theta}) during torsion. Let and denote the average shear stress in the intima-medial and adventitial layers, respectively. Hence, the relationship between the average shear stress and shear modulus takes on a form similar to Eq. 1, where G is replaced by Gm or Ga for the intima-medial or adventitial layer, respectively. The vessel wall force resultant is equal to the sum of the forces in the two layers

(4a)
or

(4b)
The total force is calculated from the measured torque as follows

(5)
The desired relationship between the shear modulus of the intact vessel and that of its two layers can be obtained by combining Eqs. 3–5 to yield

(6)
For a thin-walled vessel where ri {approx} rm and rm {approx} ra, Eq. 6 can be simplified to the form

(7)
Incidentally, Eq. 7 can be derived directly from considerations of membrane torque resultant. Because the intimamedial layer is tested mechanically after the adventitia is dissected, we can compute the shear modulus of adventitia with Eq. 6 or vice versa for the media.

The mean stresses in the circumferential ({sigma}{theta}) and longitudinal ({sigma}z) directions are given by

(8)
and

(9)
where F{lambda} and h are the longitudinal force and wall thickness, respectively. The inner radius ri of the vessel can be computed from the incompressibility condition for a cylindrical vessel as

(10)
where ro, A0, and {lambda}z are outer radii at the loaded state, the wall area in the no-load state, and the axial stretch ratio, respectively. Because all the quantities on the righthand side of Eq. 10 are measured, the loaded inner radius can be computed.

Torsion of an angiographic catheter. To determine the magnitude of the torque or shear stress induced by a slight twist of a conventional angiographic catheter, we tested two Monorail angioplasty catheters (2-Fr and 5-Fr) in torsion. A Tygon tube of ~3-mm inner diameter was fixed onto the left cannula, which was connected to the torque transducer as shown in Fig. 1. The tip of the catheter was then inserted into the lumen of the tubing, and the balloon was inflated. Inflation of the balloon within the lumen of the tube rigidly fixed the catheter, i.e., the balloon did not slip against the wall of the tube. The catheter was attached to the right cannula of the torsion machine at various distances from the balloon. Three different lengths of the catheter were tested; 50, 90, and 114 mm. The catheter was subjected to a maximum twist angle of ±10°. Subsequent to mechanical testing, a small ring was cut transverse to the length of the catheter and viewed with an optical microscope for measurements of inner and outer radii. The polar moment of inertia was computed from measurements of the geometry of the catheter.

Statistical analysis. Data are presented as means ± SE unless otherwise indicated. Statistical significance was determined by the use of ANOVA or Student's t-test. A probability of P < 0.05 was considered statistically significant.


    RESULTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
The torque and twist angle were measured directly and recorded in the computer. These direct measurements show that the relation between torque and twist rate is linear at the inflation and longitudinal extensions examined for the intact wall, media, and adventitia. Figure 3 shows typical curves for the LAD. The polar moment of inertia (J) and the segment length (L) were constant during torsion for each coronary arterial segment at a given inflation and stretch. Therefore, the shear modulus of coronary arteries is equal to the slope of the line in Fig. 3 as obtained from a least-squares fit of the data. The slopes of the lines varied with pressure and longitudinal stretch ratio. Figure 4 shows the variation of shear modulus with pressure and circumferential stress for the LAD and RCA at various stretch ratios. Figure 5 shows the variation of shear modulus with longitudinal stretch and stress for the LAD and RCA at various pressures. Comparisons of measured shear modulus of intact wall and media and that of computed adventitial modulus are shown in Figs. 6, A–C, and 7 for the eight LAD and RCA, respectively. Table 1 summarizes the data on a linear regression between shear modulus and circumferential stress for the measured intact RCA and LAD and their media. Similarly, a comparison of measured shear modulus of intact wall and adventitia and that of computed medial modulus are shown in Fig. 6, D–F, for the four LAD. The empirical constant for a least-squares fit of the relationship between shear modulus and circumferential stress is summarized in Table 2 for the measured intact LAD and its adventitia.



View larger version (34K):
[in this window]
[in a new window]
 
Fig. 3. Raw data obtained from the torsion experiments. These were typical records of torque vs. rate of twist for intact left anterior descending artery (LAD; A and B) and its intima-media after dissection from the adventitia (C and D) and adventitia that was from another LAD (E and F) at different pressures and stretch ratios ({lambda}z). A, C, and E show stretch ratio set at 1.4 and pressure varied from 3 to 11 kPa. B, D, and F show pressure set at 8 kPa and stretch ratio varied from 1.2 to 1.4.

 


View larger version (26K):
[in this window]
[in a new window]
 
Fig. 4. Relationship between the shear moduli of coronary artery and circumferential distension at various longitudinal stretch ratios. Distension is expressed in terms of pressure for the LAD (A) and right coronary artery (RCA; B). Distension is also expressed in terms of mean circumferential stress for the LAD (C) and RCA (D). A linear least-squares fit was used to describe the relationship between shear modulus (G) and circumferential stress ({sigma}{theta}) as G = {alpha} + {beta}{sigma}{theta} for the LAD and the RCA as shown in Tables 1 and 2.

 


View larger version (27K):
[in this window]
[in a new window]
 
Fig. 5. Relationship between the shear moduli of the coronary artery and longitudinal distension at various distension pressures (Pi). Distension is expressed in terms of longitudinal stretch ratio of the LAD (A) and the RCA (B). Distension is also expressed in terms of mean longitudinal stress for the LAD (C) and the RCA (D).

 


View larger version (39K):
[in this window]
[in a new window]
 
Fig. 6. Variation of shear moduli of the intact wall, intima-media, and adventitia in LAD with circumferential stress at various longitudinal stretch ratios: {lambda}z = 1.2 (A and D), {lambda}z = 1.3 (B and E), and {lambda}z = 1.4 (C and F). A linear least-squares fit of the data is given in Tables 1 (A–C) and 2 (D–F). CA, computed adventitia; MI, measured intact; MM, measured media; CM, computed media.

 


View larger version (18K):
[in this window]
[in a new window]
 
Fig. 7. The variation of shear moduli of intact wall, media, and adventitia in RCA with circumferential stress at various longitudinal stretch ratios: {lambda}z = 1.2 (A); {lambda}z = 1.3 (B); and {lambda}z = 1.4 (C). A linear least-squares fit of the data is given in Table 1.

 

View this table:
[in this window]
[in a new window]
 
Table 1. Linear regression parameters of relationship between shear modulus G and circumferential stress {sigma}{theta} as given by G = {alpha} + {beta}{sigma}{theta}

 

View this table:
[in this window]
[in a new window]
 
Table 2. Coefficients of linear regression of relationship between shear modulus G and circumferential stress {sigma}{theta} as given by G = {alpha} + {beta}{sigma}{theta}

 

The effect of direction of twist (clockwise vs. counterclockwise) is shown in Fig. 8. Figure 8A shows the experimental data with the clockwise twist in the upper quadrant and the counterclockwise twist in the lower quadrant. The solid line corresponds to a least-squares fit of the data for clockwise twist. It can be seen that there is a small angle between the curve fit and the data on the counterclockwise direction. The difference, however, is not statistically significant. Figure 8B provides a comparison between the shear modulus and the twist direction for various inflations at a given longitudinal stretch ratio. Again, we found no statistically significant differences in the direction of twist for the range of pressures and longitudinal stretch ratios examined.



View larger version (20K):
[in this window]
[in a new window]
 
Fig. 8. The effect of twist direction (clockwise and counterclockwise) on shear modulus of coronary artery. A: raw data from an LAD segment at a longitudinal stretch ratio of 1.4 and a transmural pressure of 13 kPa. The segment was twisted clockwise from 0° to 25° and then counterclockwise from 0° to –25°. The straight line corresponds to a linear square fit of the clockwise twist. J, polar moment of inertia. B: relation between shear modulus and circumferential stress at a longitudinal stretch ratio of 1.4 for clockwise and counterclockwise twist.

 

The viscoelastic properties of the coronary vessels were demonstrated through the relaxation of torque at a given twist angle. Figure 9 shows the time course of relaxation of the torque of the intact LAD and its media and adventitia for a twist angle of 25°. We observed an ~15% drop in the torque from the initial value to an asymptotic value after 5 min for both the intact wall and its media and adventitia at {lambda}z = 1.3. The time required to reach one-half of the amplitude of relaxation (time constant) was ~10 s for intact wall, ~12 s for media, and ~20 s for adventitia.



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 9. The temporal variation of shear stress, at a constant twist angle (25°), of LAD and its media (A) and LAD and its adventitia (B). The measurements were made at a longitudinal stretch ratio of 1.3 and a transmural pressure of 11 kPa. The corresponding circumferential and longitudinal stresses ({sigma}{theta} and {sigma}z) are indicated.

 

The intima-media thickness at the zero-stress state was measured from histological slides of the intact wall and of the intima-media segments where the adventitia was dissected away. For the LAD segments, the intima-media thickness was 293 ± 80.9 µm measured from the intact wall and 289 ± 46.4 µm measured from the dissected segments. For RCA segments, the thickness was 312 ± 41.2 and 306 ± 40.6 µm for the intact wall and media, respectively. No statistically significant differences in the medial wall thickness were caused by dissection. Also, the appearance of the edge of the media did not show any significant evidence of tearing or trauma.

The relationship between twist rate and torque for the angiographic catheters was also found to be linear, similar to Fig. 3. The shear modulus was found to be 220 ± 23.8 and 267 ± 20.9 MPa for the 2-Fr and 5-Fr catheters, respectively. There was no statistically significant difference between the three lengths of catheters tested. There was also no statistically significant difference in the direction of twist, i.e., the catheter is isotropic to the direction of twist.


    DISCUSSION
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
Shear modulus of coronary artery. We have found that the shear stress is linearly related to the shear strain, i.e., the shear modulus does not depend on the shear stress or strain as shown in Fig. 3. The shear modulus does, however, vary with the circumferential and longitudinal stresses and strains (Figs. 4 and 5, respectively). These findings are consistent with the study on the shear modulus of the rat aorta (3). Furthermore, we found that the dependencies of the shear modulus on the circumferential and longitudinal stresses are linear but those on strains are nonlinear. We did not find any statistically significant differences in the values of shear moduli between RCA and LAD at {lambda}z = 1.4 (physiological longitudinal stretch).

Comparison with other works. There are no previous data in the literature on the shear modulus of the coronary artery or its individual layers. The only torsion data in the literature are on the aorta. Vossoughi and Tozeren (18) measured the shear modulus on a rectangular piece of excised aorta. They did not, however, determine the effect of circumferential or longitudinal stress on the shear modulus. Humphrey et al. (8) built a triaxial torsion machine but only showed illustratory data on the aorta and carotid artery. Deng et al. (3) invented a different triaxial torsion machine and used it to obtain the first systematic set of data on the shear modulus of an intact aorta at various pressures and longitudinal strains. They found that the shear modulus of the rat aorta is 183 ± 25 kPa at physiological conditions (P = 16 kPa and {lambda}z = 1.3). The shear modulus of the RCA and LAD at physiological conditions (P = 13.3 kPa and {lambda}z = 1.4) is 210 ± 46.5 and 231 ± 55.1 kPa, respectively. Hence the porcine coronary artery is somewhat stiffer than the rat aorta in the longitudinal-circumferential direction under physiological conditions.

A two-layer model. A prominent feature of the blood vessel is the layered construction of its wall. The blood vessel wall consists of intimal, medial, and adventitial layers. For larger vessels for which the thickness of the intima is only a small fraction of that of the media, the two-layered model presented here can be considered to be sufficiently accurate. Each layer has its own zerostress state and its own elastic constants including different shear moduli.

Classically, the vessel wall was considered as a homogeneous material and the no-load state was thought to be the zero-stress state. The paradigm changed in 1983 when Fung (5) and Vaishnav and Vossoughi (15) independently discovered that the geometry of the zero-stress state is a sector that is very different from the no-load state. This recognition removed the concept of stress concentration at the inner wall of the vessel. However, the homogeneous model of the vessel wall persisted until the 1990s, with the exception of the study by von Maltzahn et al. (16, 17). In the past decade, however, the vessel has been modeled as a shell of several layers, each of which has its own elasticity constants and its own state of zero-stress resultants and zero-stress moments (1, 2, 7, 13, 20, 21).

In the present study, we assume that the vessel is a two-layered structure: one layer of vascular smooth muscles and endothelial cells, elastin, and some collagen and another layer of collagen, fibroblasts, and elastin. These are the intima-medial and adventitial layers, respectively. We found the shear modulus of the adventitia to be greater than that of the intact vessel, which was greater than that of the media. This relationship was predicted by Eq. 7, which states that the product of polar moment of inertia and shear modulus of the intact vessel is equal to the sum of the products of polar moment of inertia and shear modulus of each of the two layers. This relationship was validated by experimental data.

Viscoelastic features of shear. The hysteresis loop of the torque rate of twist relationship as shown in Fig. 3 is fairly small. The relaxation of the shear stress at a constant angle of twist is also shown in Fig. 9 for the intact vessel, media, and adventitia. Only a 15% drop in the torque from the initial value to an asymptotic value was observed. Hence, the viscoelastic feature of shear in the epicardial coronary arteries is small.

Effect of direction of twist. In coronary artery (a muscular vessel), smooth muscle is a significant component of the vessel wall. The arterial vascular smooth muscle is reported as a helical structure in the media (14). To determine the effect of direction of twist on the shear modulus, the samples were twisted in clockwise and counterclockwise directions, respectively. We found that the shear moduli in the clockwise direction were slightly larger than the shear moduli in the counterclockwise direction at any longitudinal stretch ratio and transmural pressure. The differences, however, were not statistically significant (<5%). Hence, the porcine coronary arteries can be treated mechanically as a torsionally symmetrical cylinder.

Critique of methods. The dissection of a vessel wall into separate shells without injury is not always possible. Ideally, each layer can be separated without damage and tested for its mechanical property. Because dissection invites the criticism of injury, in vivo experiments are important. Fung and Liu (6) published a method to measure the elastic constants of the two layers of the arteries in vivo that was a breakthrough. The methods proposed, however, are very difficult to use on the coronary arteries because of the motion of the blood vessel and the associated forces during the cardiac cycle. In the present study, we opted to preserve one layer while dissecting away the other layer. Indeed, a cleavage plane exists at the external elastic laminae where the dissection of the two layers is possible without significant damage to one of the layers. Figure 10 shows a histological section of the media after dissection of adventitia. There is no significant evidence of tearing or damage to the media. Furthermore, the difference in the thickness of the media measured from the intact wall and from the media where the adventitia was dissected was not statistically significant.



View larger version (66K):
[in this window]
[in a new window]
 
Fig. 10. A histological section of intact coronary artery vessel wall (A) and media after dissection of adventitia (B). IEL, internal elastic laminae; EEL, external elastic laminae. The thickness of the media (distance between IEL and EEL) is ~300 µm.

 

Isolation of the coronary artery segment for mechanical testing required the ligation and excision of side branches. The diameter of the side branches ranged from 10% to 30% of the diameter of the test segment. In the intact beating heart, these side branches may constrain the torsion of the vessel segment, i.e., the maximum twist angles of ±25° may not be realized in vivo. Despite this, however, we found the relationship between torque and rate of twist to be linear (Fig. 3); hence, the value of shear modulus measured does not depend on the degree of twist. A more significant concern may be that the presence of bifurcation may impose constraints where the torsional strain or deformation is nonuniform, unlike the present experimental setup. In this case, knowledge of the strain distribution can still lead to calculation of shear stress through the proposed constitutive relation, i.e., torsional stress-strain relation.

Finally, the dissection of vessel segments may also disrupt the vasa vasorum and its blood perfusion (or distension). Because the vasa vasorum is most abundant in the adventitia (11), this may lead to a reduction in the transmural (internal – external) pressure on the vessel wall. Our results show that the shear modulus increases linearly with the transmural pressure (Fig. 4). Hence, a local reduction in transmural pressure would cause a proportional decrease in shear modulus. The present data allow us to make the correction when the state of transmural pressure is known.

Clinical significance of study. Knowledge of the individual properties of coronary artery layers is necessary to understand the physiology and pathology of the arterial wall. For example, the two layers are innervated by baroreceptors and perfused by vasa vasorum. Shear forces at the media-adventitia border may stimulate the mechanoreceptors by mechanical deformation as well as affecting the vascular geometry of the vasa vasorum and hence the blood perfusion of the vessel wall. Kwon et al. (11) used micro-CT to study the anatomy of the vasa vasorum in the porcine coronary artery. They demonstrated that the vasa vasorum originates from the lumen of the coronary artery and runs longitudinally along the media-adventitia border. Hence, if the transmural forces at the border become abnormally high, they may collapse the vasa vasorum and cause ischemia of the vessel wall, which may lead to coronary artery disease or arteriosclerosis. Furthermore, significant differential torsional stresses at the media-adventitia border may lead to coronary artery dissection.

Catheter-induced dissection of the coronary artery is an important concern in invasive cardiology (9). The observations made in the present study may offer some guidance to minimize the occurrence. The data show that the shear modulus increases with pressure and longitudinal stretch and the difference between the shear moduli of the layers increases with an increase in pressure and stretch. When a balloon is used to distend a plaque or deploy a stent, the inflation should be done without any twist of the catheter because this would impose large differential torsional stresses at the media-adventitia border where dissection occurs. The measurements of shear modulus show that the catheter is three orders of magnitude larger than the blood vessel and any slight twist of the catheter would induce large shear stress on the vessel wall. Hence, if it is necessary to turn or twist the catheter, this should be done with a deflated balloon. Although most cardiologists may follow these practices, this study indicates possible mechanical consequences.


    DISCLOSURES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 
This research was supported in part by National Heart, Lung, and Blood Institute Grant 5-R29-HL-55554 and American Heart Association (AHA) Grant 0140036N. G. S. Kassab is the recipient of the National Institutes of Health Young Investigator Award and the AHA Established Investigator Award.


    FOOTNOTES
 

Address for reprint requests and other correspondence: G. S. Kassab, Dept. of Biomedical Engineering, Univ. of California, 204 Rockwell Engineering Ctr., Irvine, CA 92697-2715 (E-mail: gkassab{at}uci.edu).

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 DISCLOSURES
 REFERENCES
 

  1. Berry J, Rachev A, Moore JE, and Meister JJ. Analysis of the effect of a non-circular two layer stress-free state on arterial wall stresses. Proc 14th Annu Intern Conf IEEE Eng in Med and Bio Sec, 1992, p. 65–66.
  2. Demiray H and Vito RP. A layered cylindrical shell model for an aorta. Int J Eng Sci 29: 47–54, 1991.
  3. Deng SX, Tomioka J, Debes JC, and Fung YC. New experiments on shear modulus of elasticity of arteries. Am J Physiol Heart Circ Physiol 266: H1405–H1414, 1994.
  4. Dobrin PB. Mechanical properties of arteries. Physiol Rev 58: 397–460, 1978.[Free Full Text]
  5. Fung YC. What principle governs the stress distribution in living organs? In Biomechanics in China, Japan and USA, edited by Fung YC, Fukada E, and Wang J. Beijing: Science, 1983, p. 1–13.
  6. Fung YC and Liu SQ. Determination of the mechanical properties of the different layers of blood vessels in vivo. Proc Natl Acad Sci USA 92: 2169–2173, 1995.[Abstract/Free Full Text]
  7. Holzapfel GA, Gasser TC, and Ogden RW. A new constitutive framework for arterial wall mechanics and a comparative study of material models. J Elasticity 61: 1–48, 2000.
  8. Humphrey JD, Kang T, Sakarda P, and Anjanappa M. Computer-aided vascular experimentation: a new electromechanical test system. Ann Biomed Eng 21: 33–43, 1993.[Web of Science][Medline]
  9. Jain D, Kurowski V, Katus HA, and Richardt G. Catheter-induced dissection of the left main coronary artery, the nemesis of an invasive cardiologist. Z Kardiol 91: 840–845, 2002.[Web of Science][Medline]
  10. Kassab GS and Molloi S. Cross-sectional area and volume compliance of porcine left coronary arteries. Am J Physiol Heart Circ Physiol 281: H623–H628, 2001.[Abstract/Free Full Text]
  11. Kwon HM, Sangiorgi G, Ritman EL, Lerman A, McKenna C, Virmani R, Edwards WD, Holmes DR, and Swartz RS. Adventitial vasa vasorum in balloon-injured coronary arteries: visualization and quantitation by a microscopic three-dimensional computed tomography technique. J Am Coll Cardiol 32: 2072–2079, 1998.[Abstract/Free Full Text]
  12. Pao YC, Lu JT, and Ritman EL. Bending and twisting of an in vivo coronary artery at a bifurcation. J Biomech 25: 287–295, 1992.[Web of Science][Medline]
  13. Rachev A. Theoretical study of the effect of stress-dependent remodeling on arterial geometry under hypertension condition. J Biomech 30: 819–827, 1997.[Web of Science][Medline]
  14. Rhodin JAG. Architecture of the vessel wall. In: Handbook of Physiology. The Cardiovascular System. Vascular Smooth Muscle. Bethesda, MD: Am. Physiol. Soc., 1980, sect. 2, vol. II, chapt. 1, p. 1–32.
  15. Vaishnav RN and Vossoughi J. Estimation of residual strains in aortic segments. In: Biomedical Engineering II. Recent Developments, edited by Hall CW. New York: Pergamon, 1983, p. 330–333.
  16. Von Maltzahn WW, Besdo D, and Wiemer W. Elastic properties of arteries: a nonlinear two-layer cylindrical model. J Biomech 14: 389–397, 1981.[Web of Science][Medline]
  17. Von Maltzahn WW, Warriyar RG, and Keitzer WF. Experimental measurements of elastic properties of media and adventitia of bovine carotid arteries. J Biomech 17: 839–847, 1984.[Web of Science][Medline]
  18. Vossoughi J and Tozeren A. Determination of shear modulus for the material of the aorta (Abstract). Proc World Cong 1st Biomech, La Jolla, CA, 1990, p. 264.
  19. Waldman LK, Fung YC, and Covell JW. Transmural myocardial deformation in canine left ventricle: normal in vivo three-dimensional finite strains. Circ Res 57: 152–163, 1985.[Abstract/Free Full Text]
  20. Xie JP, Zhou JB, and Fung YC. Bending of blood vessel wall: stress-strain laws of the intima-media and adventitial layers. J Biomech Eng 117: 136–145, 1995.[Web of Science][Medline]
  21. Yu Q, Zhou JB, and Fung YC. Neutral axis location in bending and Young's modulus of different layers of arterial wall. Am J Physiol Heart Circ Physiol 265: H52–H60, 1993.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
M. Garcia and G. S. Kassab
Right coronary artery becomes stiffer with increase in elastin and collagen in right ventricular hypertrophy
J Appl Physiol, April 1, 2009; 106(4): 1338 - 1346.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Y. Liu, W. Zhang, and G. S. Kassab
Effects of myocardial constraint on the passive mechanical behaviors of the coronary vessel wall
Am J Physiol Heart Circ Physiol, January 1, 2008; 294(1): H514 - H523.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. Zhang, Y. Liu, and G. S. Kassab
Flow-induced shear strain in intima of porcine coronary arteries
J Appl Physiol, August 1, 2007; 103(2): 587 - 593.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
C. Wang, M. Garcia, X. Lu, Y. Lanir, and G. S. Kassab
Three-dimensional mechanical properties of porcine coronary arteries: a validated two-layer model
Am J Physiol Heart Circ Physiol, September 1, 2006; 291(3): H1200 - H1209.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
G. A. Holzapfel, G. Sommer, C. T. Gasser, and P. Regitnig
Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling
Am J Physiol Heart Circ Physiol, November 1, 2005; 289(5): H2048 - H2058.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. Pandit, X. Lu, C. Wang, and G. S. Kassab
Biaxial elastic material properties of porcine coronary media and adventitia
Am J Physiol Heart Circ Physiol, June 1, 2005; 288(6): H2581 - H2587.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
X. Lu, A. Pandit, and G. S. Kassab
Biaxial incremental homeostatic elastic moduli of coronary artery: two-layer model
Am J Physiol Heart Circ Physiol, October 1, 2004; 287(4): H1663 - H1669.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (22)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lu, X.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lu, X.
Right arrow Articles by Kassab, G. S.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2003 by the American Physiological Society.