,Cardiovascular Imaging Center and Section of Electrophysiology, Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, Cleveland, Ohio 44195
Submitted 27 June 2003 ; accepted in final form 28 August 2003
| ABSTRACT |
|---|
|
|
|---|
) were evaluated with the use of a conductance catheter for 100 consecutive cardiac cycles. Beat-to-beat analysis revealed a cascade of important causal relations. LV-FT showed a significant positive linear relationship with Evti (r = 0.87). Importantly, there was a significant positive linear relationship between the RR interval and LV-EDV in the same cardiac beat (r = 0.53). Consequently, there was a positive linear relationship between LV-EDV and subsequent peak systolic LVP (r = 0.82). Furthermore, there were significant positive linear and negative curvilinear relationships between peak systolic LVP and dP/dtmin (r = 0.95) and
(r = 0.85), respectively, in the same cardiac beat. In addition, there was a significant negative curvilinear relationship between dP/dtmin and
(r = 0.86). We have concluded that the determinants of LV diastolic function in individual beats during AF depend strongly on the peak systolic LVP. This suggests that the major benefit of slower ventricular rate appears related to lengthening of LV filling interval, promoting subsequent higher peak systolic LVP and greater LV relaxation.
filling interval; left ventricular pressure
It is well recognized that patients with normal sinus rhythm who arrive at the hospital with heart failure are frequently found to have diastolic rather than systolic dysfunction (23). However, the identification of diastolic dysfunction is circumstantial because the diagnosis is often made by ruling out the presence of systolic dysfunction in the presence of heart failure symptoms. The presence of AF further complicates our ability to identify diastolic dysfunction because irregular RR intervals result in constantly changing loading conditions, and the applicability of Doppler echocardiography methods is impaired by the lack of atrial contraction. In addition, there is still insufficient understanding of the basic physiological mechanisms underlying cardiac hemodynamics during AF.
We have recently reported (24, 26, 27) that slowing of ventricular rate by selective atrioventricular nodal vagal stimulation during AF improved both LV contractility and relaxation. It has been speculated that rapid ventricular rate with inadequate LV filling time during AF might be the major factor limiting cardiac performance (3). It should be noted, however, that these results were obtained by an analysis of averaged parameters for >100 consecutive cardiac cycles without insights from beat-to-beat analysis. We have previously reported the existence of linear relationships between LV systolic parameters and the ratio of preceding (RR1) and prepreceding (RR2) RR intervals (RR1/RR2) in individual beats during rapid AF (17, 21), as well as nonlinear relationships with a plateau when ventricular rate was slowed (17). In contrast, the parameters of LV diastolic function have shown nonlinear relationship with RR1/RR2 during both rapid and slow ventricular rates (17).
The purpose of this study was therefore to better elucidate the physiological determinants of beat-to-beat changes in the LV diastolic function during AF and to quantify their relationship with the corresponding RR intervals. We used a combination of Doppler echocardiography and hemodynamic analysis to test the hypothesis that the determinants of LV diastolic function during AF depend largely on the beat-to-beat changes in preload that reflect the variability of individual RR intervals.
| METHODS |
|---|
|
|
|---|
Surgical preparation. Twelve healthy mongrel dogs weighing between 25 and 35 kg were used in the present study. The animals were placed in the supine position and were initially premedicated with 20 mg/kg thiopental sodium intravenously and intubated with a cuffed endotracheal tube. The animals were ventilated with room air supplemented with oxygen as needed to maintain normal arterial blood gases with the use of a SAV respirator (Narkomed 2, North American Dräger; Telford, PA). Anesthesia was maintained with an inhalation mixture of oxygen and isoflurane (1.02.0%) throughout the experiment. Metabolic environments for the animals were maintained at a PO2 >80 mmHg, PCO2 3545 mmHg, and pH 7.357.45 by infusing bicarbonate solutions and/or changing ventilation volume and rate. The left external jugular vein was cannulated to infuse normal saline solution at 100200 ml/h to replace spontaneous fluid losses. Standard surface ECG leads (I, II, and III) were continuously monitored. A rectal probe (model TM-2400, Electromedics) was used to monitor body temperature. An electrical heating pad was then placed under the animal, and operating room lamps were used to maintain a body temperature of 3637°C.
A conductance catheter with a pressure sensor (model SPC-562, Millar Instruments; Houston, TX) was inserted into the left carotid artery and advanced such that the tip was near the LV apex to acquire the LV pressure and volume curve. Before the insertion, the catheter was soaked in warm saline for 30 min and precalibrated to the air. A median sternotomy was performed to expose the heart and a pericardial cradle was created to support the heart. Custom-designed Ag-AgCl quadripolar electrodes for recording and bipolar pacing were sutured to the high right atrium and right ventricular apex. Similar bipolar plate electrodes were also sutured to two epicardial fat pads that contain parasympathetic neural pathways selectively innervating the sinus node and the atrioventricular node, respectively. The sinus node fat pad was located at the right pulmonary vein-atrial junction, and the atrioventricular fat pad was located at the junction of inferior vena cava and the left atrium. All signals (surface ECGs, right atrial and ventricular electrograms, and LV pressure and volume) were amplified, filtered, digitized, and continuously displayed on a monitoring system (GE Marquette Medical Systems, Prucka-Cardiolab EP System).
Electrical stimulation. A programmable eight-channel stimulator (Master-8, AMPI) was used to generate the desired sequence of rectangular impulses for atrial pacing or nerve stimulation. The amplitude of the impulses was determined by current isolators (model A360, WPI) that also permitted alteration of the polarity of the impulse to reduce the effects of polarization at the electrode-tissue interface. After the surgical procedures were completed, stabilization period of 30 min at normal sinus rhythm was allowed. AF was then induced by a two-step maneuver as previously reported (17, 21). AF was triggered by brief burst (510 s) of right atrial pacing (510 mA, 1-ms pulses at 20 Hz) and maintained by sinus node fat pad stimulation (47 mA, 50-µs pulse duration at 20 Hz), which provided selective vagal stimulation to the sinus node and surrounding atrium. The sinus node fat pad stimulation did not capture the atrium. In this fashion, AF could be maintained for many hours, and in some cases, spontaneous AF persisted even when the supporting vagal stimulation was withdrawn. After a period of AF stabilization of at least 15 min, the following hemodynamic and echocardiographic assessments were performed.
Data acquisition and analysis. After preamplification with a Gould universal amplifier (Gould; Valley View, OH), the ECG waveform was digitized with 1-ms resolution using a 12-bit analog-to-digital converter (National Instruments; Austin, TX) interfaced with a Pentium 200 MHz computer running customized software developed in the LabView graphical programming environment (National Instruments). Both of the electrical and hemodynamic data were recorded into data-acquisition boards simultaneously during AF. An analysis of simultaneous electrical and hemodynamic data was performed within the LabView program off-line.
Hemodynamic assessment was performed in each animal. The peak systolic LV pressure (LVP) was measured from the LV pressure curve and LV end-diastolic volume (EDV) was obtained from the LV volume curve (Fig. 1, top). The maximum (dP/dtmax) and minimum (dP/dtmin) value of the first derivative of LV pressure curve and the time constant of isovolumic LV pressure decay (
) was obtained by digitizing the waveform off-line. The
was determined by fitting the pressure-time data (from the point of dP/dtmin to LV pressure 5 mmHg higher than next LV end-diastolic pressures) to the equation P(t) = (P0 Pb) et/
+ Pb, where Pb is the pressure decay asymptote, P0 is the pressure at dP/dtmin, and t is time referenced to time of dP/dtmin occurrence (19). An interval of >25 ms was considered necessary to calculate
. The RR intervals were measured from the right ventricular electrogram for >100 consecutive cardiac cycles. The RR1 and RR2 intervals for a given cardiac beat (marked with an asterisk) were measured for each cardiac cycle along with all of the parameters during AF (Fig. 1, middle).
|
Echocardiographic assessments. Epicardial echocardiography was performed in 9 of 12 animals using commercially available equipment (Sequoia C512, Siemens Medical Solutions; Mountain View, CA) with a 3.5 MHz phased array transducer. From the four-chamber view, the pulsed Doppler mitral inflow velocity profile was obtained by placing the sample volume at the tips of the mitral leaflets. The peak pulsed Doppler early diastolic mitral inflow velocity (E) and its velocity time integral (Evti) were measured from the recording (Fig. 1, bottom). The Evti was measured off-line by digitizing the darkest portion of the tracings. The LV filling time (FT) was measured as the time from the onset to the end of mitral inflow E wave. We attempted to measure each parameter for >100 consecutive cardiac cycles; however, the number of data points involving mitral inflow E wave velocity was usually less due to intermittent suboptimal signal quality.
Statistical analysis. The dP/dtmax, dP/dtmin,
, and peak systolic LVP at a given cardiac beat were correlated with the RR1 interval as well as with RR1/RR2. The relationship between the Doppler-derived parameters, including peak E wave velocity, Evti, LV-FT, and LV-EDV obtained by a conductance catheter at a given cardiac beat were correlated with their RR interval. The difference in correlation coefficients in the relationship between dP/dtmax and RR1 or RR1/RR2 as well as those between LV-FT and mitral inflow E wave velocity or Evti was evaluated by Fisher's Z transformation, followed by Student's paired t-test. The LV-EDV was further correlated with the subsequent peak systolic LVP. Finally, the dP/dtmin and
were correlated with the peak systolic LVP in the same cardiac beat. A P value <0.05 was considered statistically significant.
| RESULTS |
|---|
|
|
|---|
Relationship between dP/dtmax and RR intervals. As previously reported (21), there was a significant positive linear relationship between the preceding RR1 interval and subsequent dP/dtmax (Fig. 2A). A similar linear relationship was found when the parameter was the RR1/RR2 (Fig. 2B). The averaged data from all dogs confirmed that the correlation coefficient was significantly greater for the latter relationship during AF (r = 0.79 vs. r = 0.59; P < 0.01). This finding indicates that both the mechanical restitution (through RR1) and postextrasystolic potentiation (through RR2) play important mechanistic role as determinants of beat-to-beat variability of contractility.
|
Relationship between dP/dtmin,
, peak systolic LVP, and RR intervals. In accordance with our working hypothesis, we sought to determine whether similar simple linear relationships existed between the RR variability and the diastolic parameters. However, unlike the strong linear correlation documented in Fig. 2, a simple linear regression analysis did not reveal a significant relationship. Thus we only found positive curvilinear trends between dP/dtmin and RR1 intervals (or RR1/RR2), as well as negative curvilinear trends for
(Fig. 3, A, D, B, and E). Interestingly, there were also positive curvilinear trends between peak systolic LVP and the RR intervals (Fig. 3, C and F). Although the above analysis did not reveal simple linear relationships, it nevertheless confirmed the deleterious role of short RR intervals during AF. Moreover, it suggested the possible functional role of peak systolic LVP as an important factor determining LV diastolic function. In particular, because small values for both RR1 and RR1/RR2 were consistently associated with small peak systolic LVP (Fig. 3, C and F), we were prompted to elucidate its impact on the diastolic characteristics.
|
Relationship between Doppler echocardiography parameters and RR intervals, LV-EDV, and peak systolic LVP. First, as demonstrated in Fig. 4A from a representative experiment, there was a significant positive linear relationship between the RR1 intervals and Doppler-derived LV-FT in the same cardiac beat. This tendency was observed in all animals (mean r = 0.55, range 0.39
0.81). Second, LV-FT showed a significant positive linear relationship with peak mitral inflow E wave velocity (data for all animals are shown in Table 1, mean r = 0.52, range 0.42
0.64) and even stronger correlation with Evti (representative example in Fig. 4B; all data in Table 1, mean r = 0.87, range 0.74
0.95). Third, as could be deduced from the correlation between the RR intervals and the filling indexes, there was a significant positive linear relationship between RR interval and LV-EDV obtained from LV volume curve (representative example in Fig. 4C; mean r = 0.53, range 0.34
0.74). Finally, there was a strong positive linear relationship between LV-EDV and subsequent peak systolic LVP (representative example in Fig. 4D; all data in Table 1, mean r = 0.82, range 0.79
0.90).
|
|
These findings demonstrated that longer RR intervals were associated with improved filling indexes (filling time FT and volume Evti) and LV-EDV that led to augmentation of the peak systolic pressure in the studied beat during AF. The question remained whether and to what extent did the increased systolic pressure affect the diastolic parameters.
Relationship between dP/dtmin and
, and the peak systolic LVP. As shown in Fig. 5, AL, each of the 12 animals showed a strongly significant positive linear relationship between dP/dtmin and peak systolic LVP (Table 1, mean r = 0.95, range 0.87
0.98) and a strongly negative curvilinear relationship between
and peak systolic LVP in the same cardiac beat during AF (Fig. 6; Table 1, mean r = 0.85, range 0.46
0.96). A significant negative curvilinear relationship was found between the two parameters
and dP/dtmin in each case (Fig. 7; Table 1, mean r = 0.86, range 0.56
0.98).
|
|
|
These findings revealed the complex sequel of relations between the diastolic parameters and the individual beat-to-beat variability during AF, and confirmed our working hypothesis that beats with longer coupling intervals RR1, as well as those with additional postextrasystolic booster (i.e., large RR1/RR2), end up with an elevated LVP that in turn plays an important role for the improved diastolic characteristics during AF.
| DISCUSSION |
|---|
|
|
|---|
directly depends on the peak systolic LVP (Figs. 5 and 6) and therefore on the preceding RR variability. In brief, prolongation of the RR intervals during AF augments LV filling volume, increases the following peak systolic LVP and thereby results in improved subsequent LV relaxation. Force-interval relationship and Frank-Starling mechanism effect on LV systolic function during AF. Although evaluation of LV performance during AF is inherently difficult because of its beat-to-beat variability, the role of the preceding RR intervals has been well established in determining LV systolic function (1, 9, 11, 12, 16, 18, 20, 21). Specifically, the LV systolic variables show positive and negative linear relationships with RR1 and RR2 intervals, respectively (9, 11, 12, 18). These phenomena were explained by interaction of the force-interval relationships: mechanical restitution governed by RR1 and postextrasystolic potentiation determined by RR2 (18), as well as by the Frank-Starling mechanism (1). Extrapolating from these mechanisms, Suzuki et al. (20) and we (21) have reported that LV systolic variables at RR1/RR2 = 1 in the linear regression line could be a good indexes of the averaged LV systolic function during AF.
Is Frank-Starling mechanism involved in LV diastolic function during AF? On the other hand, there were fewer reports (5, 1417) paying attention to the LV diastolic function during AF. We expected to find simple rules, similar to those governing the systolic performance that could be used to estimate LV diastolic function based on the force-interval relationship and/or Frank-Starling mechanism. However, the present study did not show simple linear relationship between LV diastolic parameters and RR1 interval or RR1/RR2 ratio. Nakamura et al. (16) have previously reported that
did not show correlation with RR1 interval or RR1/RR2 ratio and that
was fairly constant for a wide range of these parameters. These authors concluded that there should be independent mechanisms for regulating contractility and relaxation. To a certain degree, these results are consonant with our findings that no simple linear relationship existed between LV diastolic parameters and RR1 or RR1/RR2 ratio. However, in the present study,
was never constant when RR intervals varied greatly, and long RR intervals consistently yielded small
(Fig. 3B). Careful analysis revealed that both diastolic parameters, dP/dtmin and
, had strong linear and curvilinear relationships, respectively, with peak systolic LVP (Figs. 5 and 6), which directly correlated to LV-EDV (Fig. 4D) and was thus associated with the duration of the preceding RR interval (Fig. 4C). From these results, one should conclude that LV relaxation was more dependent on the Frank-Starling mechanism (via LV-EDV) than directly on the force-interval relationships (via RR1/RR2).
Mechanistic relationship between peak systolic LVP and LV diastolic function during AF. During sinus rhythm, Weisfeldt et al. (25) has already reported that LV relaxation is determined primarily by peak systolic LVP. An increase in systolic LVP at longer filling period caused increase in dP/dtmin reflecting faster initial LVP fall (4). Brausaert et al. (2) has reported that a more rapid relaxation should be corresponding to an acute reduction in LV systolic volume simply by virtue of restoring forces. It has been reported (14) that interventions that enhance the systolic shortening augment relaxation. In the present study, during AF, we found that dP/dtmin and
did not correlate directly with preceding RR1 interval, but these parameters were significantly correlated with peak systolic LVP. This indicates that the longer RR intervals produced greater LV-EDV and, according to the Frank-Starling mechanism, greater subsequent peak systolic LVP thus promoting greater LV contractility and relaxation.
Potential benefit of slowing the ventricular rate during AF. We have previously reported the benefits of slower ventricular rate during AF on LV diastolic function (17, 24, 26, 27). In these studies, the improvement of diastolic parameters was demonstrated during selective atrioventricular nodal vagal stimulation by analysis of averaged values of diastolic parameters for >100 consecutive cardiac beats. In particular, prolongation of the average RR interval caused an improvement of the average dP/dtmin. The results from the present study, based on beat-to-beat analysis, further expand these results and provide mechanistic explanation for the observed improvement of LV diastolic function by vagally induced slowing of the ventricular rate in AF.
Study limitations. Because of the nature of animal studies, certain limitations should be considered in our experiments. First, AF was acutely induced by burst stimulation of the right atrium and was perpetuated by periodical selective vagal stimulation to the sinus node in anesthetized open-chest dogs. The resultant ventricular responses were fast and random, but their sequence might be different in patients with chronic AF. Moreover, although the present data are strongly suggestive about the benefits of rate control, separate studies are needed during controlled slowing because filling volume and peak systolic LVP might have different dependence in the range of substantially longer RR intervals (13). Second, we used healthy mongrel dogs in this study. However, the relationships between filling intervals, peak systolic LVP, and LV relaxation during AF might be disturbed in patients with organic heart disease. Third, it is generally accepted that
is a more reliable diastolic index than dP/dtmin because it is not influenced by preload or afterload and is derived from multiple pressure measurements throughout the entire period of isovolumic relaxation (8). Furthermore, the LV relaxation determined by
(in contrast to dP/dtmin) was reported to be independent of systolic pressure (7, 22). This seeming discrepancy with our results most likely reflects the fact that the above studies were performed during sinus rate but not AF. In the present study, changes of both
and dP/dtmin corresponded well to the peak systolic LVP. Furthermore, there was a significant curvilinear relationship between the
and dP/dtmin, suggesting that both parameters are reliable indices for beat-to-beat analysis during AF.
We conclude that for individual beats during AF, the LV relaxation is determined by the peak systolic LVP, which, in turn, is proportional to the preceding LV filling interval. Slowing of the ventricular rate during AF might benefit the diastolic function by utilizing a functional link between the prolonged LV filling interval and the subsequent higher peak systolic LVP, promoting greater LV relaxation.
| ACKNOWLEDGMENTS |
|---|
GRANTS
This work was supported by American Heart Association Grant AHA-9808489A and National Heart, Lung, and Blood Institute Grant RO1-HL-60833-01A1 (to T. N. Mazgalev).
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
ZB, Mowrey KA, Zhang Y, Zhuang S, Tabata T, Wallick DW, Grimm RA, and Thomas JD. Slow rate during AF improves ventricular performance by reducing sensitivity to cycle length irregularity. Am J Physiol Heart Circ Physiol 283: H2706H2713, 2002.
ZB, Grimm RA, Natale A, and Mazgalev TN. Ventricular rate control by selective vagal stimulation is superior to rhythm regularization by atrioventricular nodal ablation and pacing during atrial fibrillation. Circulation 106: 18531858, 2002.This article has been cited by other articles:
![]() |
K. Kusunose, H. Yamada, S. Nishio, N. Tomita, T. Niki, K. Yamaguchi, K. Koshiba, S. Yagi, Y. Taketani, T. Iwase, et al. Clinical Utility of Single-Beat E/e' Obtained by Simultaneous Recording of Flow and Tissue Doppler Velocities in Atrial Fibrillation With Preserved Systolic Function J. Am. Coll. Cardiol. Img., October 1, 2009; 2(10): 1147 - 1156. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. B. Popovic and A. L. Klein Cracking the Mysteries of Diastolic Function in Atrial Fibrillation: New Technology for an Old Problem J. Am. Coll. Cardiol. Img., October 1, 2009; 2(10): 1157 - 1158. [Full Text] [PDF] |
||||
![]() |
J. Asada-Kamiguchi, T. Tabata, Z. B. Popovic, N. L. Greenberg, Y. J. Kim, M. J. Garcia, D. W. Wallick, K. A. Mowrey, S. Zhuang, Y. Zhang, et al. Non-invasive assessment of left ventricular relaxation during atrial fibrillation using mitral flow propagation velocity Eur J Echocardiogr, October 1, 2009; 10(7): 826 - 832. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Hay, J. Rich, P. Ferber, D. Burkhoff, and M. S. Maurer Role of impaired myocardial relaxation in the production of elevated left ventricular filling pressure Am J Physiol Heart Circ Physiol, March 1, 2005; 288(3): H1203 - H1208. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||