|
|
||||||||
1Department of Cardiovascular Dynamics, National Cardiovascular Center Research Institute, Suita 565-8565; and 2Organization for Pharmaceutical Safety and Research, Tokyo 100-0013, Japan
Submitted 17 July 2003 ; accepted in final form 28 January 2004
| ABSTRACT |
|---|
|
|
|---|
venous return; cardiac output; hemodynamics
|
To overcome the limitation of the framework of Guyton et al., Sunagawa et al. (24, 30) proposed a novel framework of circulatory equilibrium. In the framework of Sunagawa et al., the venous return properties of the systemic and pulmonary circulations are integrated to deal with blood volume redistribution between the two circulations. A mathematical analysis using a simple linearized model (see APPENDIX) indicated that venous return (COV) for a given stressed volume (V) forms a flat surface (venous return surface) as a function of PRA and left atrial pressure (PLA; Fig. 1B). This is formulated as follows
![]() | (1) |
This extended framework of Guyton et al. allows us to predict circulatory equilibrium, even in the presence of unilateral ventricular dysfunction, making it useful in clinical settings where complex pathophysiologies must be interpreted. With this framework for guidance, proper management of low CO and/or pulmonary congestion should improve the prognosis of cardiac patients (10, 21). However, the characteristics of the venous return surface have never been experimentally studied. Therefore, it is not known whether the simple flat surface represents the integrated venous return of the pulmonary and systemic circulations.
The purpose of this investigation was to experimentally validate the concept of the venous return surface (24, 30). To examine the characteristics of the venous return surface, we determined W, GS, and GP using a total heart bypass preparation. To examine the invariability of the characteristics of the venous return surface under a range of stressed volumes among animals, we predicted the circulatory equilibrium from the intersection of the measured integrated CO curve and the venous return surface, as defined by the standard set of parameters. The results indicated that the venous return surface was indeed remarkably flat. Its parameter values were invariable enough among animals that circulatory equilibrium for a given integrated CO curve could be predicted under unilateral heart failure as well as during normal cardiac function.
| METHODS |
|---|
|
|
|---|
Care of the animals was in strict accordance with the guiding principles of the Physiological Society of Japan. We used seven adult male mongrel dogs (26.3 ± 2.4 kg) for examination of the venous return surface and another 12 male dogs (26.1 ± 3.2 kg) for measurement of the integrated CO curve to predict circulatory equilibrium.
Dogs were anesthetized with pentobarbital sodium (25 mg/kg) and intubated endotracheally. Urethane (250 mg/ml) and
-chloralose (40 mg/ml) were continuously infused (0.3 ml·kg1·h1) to maintain an appropriate level of anesthesia during the experiments. A 5F catheter was placed in the right femoral vein for administration and withdrawal of blood, fluids, and drugs. To stabilize autonomic tone, we isolated the carotid sinus bilaterally and kept the intrasinus pressure constant (120 mmHg) (27). The cervical vagosympathetic trunks were cut to eliminate their buffering effects. Systemic arterial pressure was measured through a fluid-filled catheter placed in the thoracic aorta via the left common carotid artery and connected to a pressure transducer (model DX-200, Nihon Kohden). After a median sternotomy, the heart was suspended in a pericardial cradle. Fluid-filled catheters were placed in the right and left atrium and in the main trunk of the pulmonary artery for measurement of PRA, PLA, and pulmonary arterial pressure, respectively. The junction of the vena cava and the right atrium was taken as the reference point for zero pressure.
To examine the venous return surface, we performed a total heart bypass (Fig. 2). The perfusion system was initially primed with
200 ml of heparinized blood from another dog. Two roller pumps (MERA) were used to control systemic and pulmonary flows. A systemic perfusion cannula was placed in the right common carotid artery. A draining cannula for the systemic circulation was inserted into the right ventricle through its free wall. A pulmonary perfusion cannula was placed in the pulmonary artery through the right ventricle. A draining cannula for the pulmonary circulation was introduced into the left ventricle via the apex. The flow rates of both pumps were measured by in-line electromagnetic flow probes (model MFV-2100, Nihon Kohden). The two probes were simultaneously calibrated using a graduated cylinder. Both pumps began with an initial flow rate of 80 ml·min1·kg1. Finally, umbilical tape placed around the pulmonary artery to hold the pulmonary cannula was tightened, and the ascending aorta was clamped, thus switching to the total heart bypass. Ligation of the coronary arteries arrested the heart.
|
Experimental Protocol
Characterization of the venous return surface. After a stable condition was obtained, the flow rates of both pumps were varied stepwise from 40 to 100 ml·min1·kg1 in 20 ml·min1·kg1 increments (Fig. 3). At flow rates of 60 and 80 ml·min1·kg1, we varied the blood volume distribution between the pulmonary and systemic circuits by transiently unbalancing the flow rates of the two pumps. Steady state was attained in each flow rate within 50 s. In each step, we measured pump flow rate and bilateral atrial pressure during temporary suspension of ventilation at end expiration. We obtained a total of six recordings in each dog. To estimate W, we removed or added blood volume by 5 to +4 ml/kg, which was assumed to alter only the stressed blood volume. Because we isolated the baroreceptors, baroreflex-related changes in unstressed volume were negligible. We then repeated the same protocol.
|
200 ml of whole blood. We then withdrew blood in 2 ml/kg steps up to a total of 1022 ml/kg (511 steps for a single animal) while measuring CO and bilateral atrial pressures (Fig. 4). As in the first protocol, we assumed that this volume reduction altered only the stressed blood volume of the systemic and pulmonary circulation. We defined the reference stressed volume when half of the infused blood was withdrawn. This reference was used when stressed volume was changed to predict circulatory equilibrium. In six other dogs, left ventricular failure was induced by embolization of the left circumflex coronary artery with glass microspheres (90 µm diameter) (35). We adjusted the number of microspheres to increase PLA by 20 mmHg. We then volume loaded the animals and repeated the same protocol.
|
All analog signals were digitized at 200 Hz with a 12-bit analog-to-digital converter (Contec, Osaka, Japan) using a dedicated laboratory computer system; the data were then stored on a hard disk for subsequent analysis. All the recorded data were averaged over 5 s and expressed as means ± SD. All data, excluding pressure data, were normalized to individual body weight. The level of statistical significance was defined as P < 0.05.
Derivation of parameters of the venous return surface. We used the algebraic mean of the flow rates of pumps 1 and 2 as COV. A multivariate linear regression was performed on a set of six recordings, with Eq. 1 used to derive GS and GP in each dog. We repeated the same analysis when the stressed volume was changed. Because changes in the stressed volume did not significantly affect GS or GP, we derived W as the ratio of changes in stressed volume to the amount of parallel shift of the venous return surface (see APPENDIX). To test the goodness of fit of the multivariate regression equation as a representation of the venous return surface, the multiple coefficient of determination (r2) and the standard error of estimate (SEE) were calculated. To estimate the error relative to the average value of the respective parameters, we derived coefficients of variation for GS, GP, and W.
Prediction of Circulatory Equilibrium
To characterize the CO curve for each animal as a function of PRA and PLA, we fitted CO as a function of PRA using a three-parameter logarithmic curve
![]() | (2) |
![]() | (3) |
Coefficients of fitted logarithmic functions,
R,
R, and
R and
L,
L, and
L, characterized the CO curve of the right and left heart, respectively. They were determined by the least-squares method (Fig. 5A).
|
| RESULTS |
|---|
|
|
|---|
Figure 6 shows a representative venous return surface as a function of PRA and PLA. All six points measured are aligned on a unique flat surface. The alignment is even clearer if the data points are viewed from a direction parallel to the surface (Fig. 6, inset). The six points obtained from each animal were closely aligned on a flat surface (Fig. 7). Table 1 summarizes the parameter values obtained from seven dogs. The fact that the multiple correlation of determination was close to unity (r2 = 0.920.99), with a small SEE relative to the amount of venous return, suggested that the approximation of venous return by a flat surface was reasonably accurate.
|
|
|
Prediction of CO, PRA, and PLA
Table 2 shows a summary of the approximation of the integrated CO using a three-parameter logarithmic curve. In each animal, the coefficient of determination was high for the CO curve of the right ventricle (r2 = 0.960.99) and the left ventricle (r2 = 0.890.99) under normal cardiac conditions. In other words, the logarithmic curves represented the integrated CO curve with reasonable accuracy. The logarithmic function remained a good approximation under the condition of unilateral heart failure, as evidenced by the high coefficients of determination: r2 = 0.730.99 and 0.840.99 for the CO curves of the right and left ventricles, respectively.
|
|
Predicted PLA, as a whole, agreed reasonably well with PLA measured over a wide range (y = 0.89x + 0.5, n = 104, r2 = 0.98, SEE = 0.8 mmHg; Fig. 8C). The ratio of SEE to the mean of the predicted PLA was 0.087.
| DISCUSSION |
|---|
|
|
|---|
Characteristics of the Venous Return Surface
The venous return surface was remarkably flat. Its flatness is attributable to the constant nature of W, GS, and GP during changes in loading conditions. Because these parameters are a complex function of vascular resistance and compliance and their distributions (see APPENDIX), the flatness of the surface would depend on how constant the vascular resistance and compliance remained, irrespective of loading conditions. Drees and Rothe (9) found that compliance of the total vasculature was remarkably constant from 5 to 25 mmHg of mean circulatory filling pressure. Grodins et al. (13) reported a fairly linear relation between the systemic venous return and PRA from 5 to 20 mmHg. These reports and many other studies (8, 18, 26) demonstrated the constant nature of vascular compliance and resistance in physiologically normal pressure ranges. However, it is uncertain whether the parameters remain constant when the pressure range is further expanded to include lower or higher values (1, 7, 16). The venous return curve of Guyton et al. (16) reaches a maximum value and remains on a plateau at all PRA less than 2 mmHg. Although we did not observe such a curvature of the venous return surface, it is conceivable that the surface might not be flat if we were to impose extreme experimental conditions. Nevertheless, it is fair to say that the venous return surface is reasonably flat within a physiologically normal range of pressures.
A standard set of parameters for the venous return surface enabled us to predict CO and atrial pressures for changes in stressed volume, if the CO curve is defined. The lack of variability of three parameters (W, GS, and GP) among animals is the underlying reason for this observation. As indicated in the APPENDIX, these parameters are complex functions of vascular resistance and compliance and their distributions. Therefore, the lack of variability of these parameters reflects the lack of variability of vascular resistance and compliance and their distributions among animals. Indeed, reported values for total compliance and resistance for venous return of the pulmonary and systemic circulation were very close (19, 26). The values for W, GS, and GP estimated by combining data of Lee and Goldman (19) and data of Shoukas (26) are 0.131 min, 14.56 ml·min1·mmHg1·kg1, and 2.39 ml·min1·mmHg1·kg1, respectively (see APPENDIX), which are reasonably close to the standard values of the venous return surface parameters obtained in this study. Thus the parameter values obtained in our study are not specific for our experiment but are generally reproducible.
Integrated CO Curve
We measured the CO curves of both ventricles by changing the stressed blood volume (25, 28). The mean slopes of the right and left CO curves under normal cardiac conditions were 55.6 ± 18.7 and 27.2 ± 12.3 ml·min1·mmHg1·kg1, respectively, which are reasonably close to those found in the previous study (28).
A three-parameter logarithmic function approximated the CO curves well. According to the framework of ventricular-arterial coupling using the volume-elastance concept, CO, or stroke volume under a constant contractility, arterial resistance and heart rate depend linearly on end-diastolic volume (24, 29). Therefore, the logarithmic relation between CO and atrial pressure would be a manifestation of the logarithmic relation between end-diastolic volume and filling pressure. This is indeed reasonable, because the pressure-volume relation of the diastolic ventricle is known to be exponential; therefore, the volume-pressure relation should be the inverse of exponential, i.e., logarithmic (12).
Mechanical parameters such as ventricular systolic and diastolic elastance, heart rate, ventricular interdependence, and arterial resistance have been shown to affect CO (22, 24). To clarify therapeutic targets in the management of cardiac patients, it is crucial to relate those mechanical parameters to the CO curve, as we have done with the venous return surface. Modeling the CO curve on the basis of those parameters is clearly required in future studies.
Analysis of the Circulatory Equilibrium
The venous return surface, combined with the integrated CO curve in the three-dimensional diagram, enables us to make intuitive and in-depth analyses of the contribution of the individual system components to hemodynamics. Figure 9 illustrates the effect of left heart failure on circulatory equilibrium. Integrated CO curves, which were experimentally obtained from a dog under normal and left heart failure conditions, are superimposed on the standard venous return surface in Fig. 9A. Under the normal condition, the integrated CO curve intersects the surface at a CO of 115 ml·min1·kg1, with a PRA of 2.5 mmHg and a PLA of 4.1 mmHg. In contrast, left heart failure lessens the slope of the CO curve and diverts it toward the axis of PLA. At the intersection of the standard surface and the CO curve under left heart failure, although the CO decreased (85 ml·min1·kg1), the increase in PLA (9.3 mmHg) was modest. When the stressed blood volume is increased to simulate the baroreflex response (+8 ml/kg), the surface shifts upward (Fig. 9B). The intersection reached a new equilibrium point, where PLA increased drastically (15.9 mmHg) with a slight increase in PRA and a partial recovery of CO. Although this analysis is hypothetical, the graphical analysis represents the typical hemodynamics of left heart failure (2, 4, 10, 23, 35). Notwithstanding its simplicity, the framework for the venous return surface provides a very powerful tool for analysis of complicated hemodynamics in the clinical setting.
|
Many studies have modeled hemodynamics of the cardiovascular system (35, 20, 31, 33). The parallel circuit model of Caldini et al. (5) seems to be more appropriate than our serial model for an anatomically oriented analysis of hemodynamics within a single circulation, i.e., the analysis of blood redistribution between the splanchnic and nonsplanchnic circuits. Levy (20) simplified blood distribution between the arterial and venous compartments with a lumped serial model. Although these models could analyze hemodynamics within a single circulation, they were not intended to deal with blood redistribution between the systemic and the pulmonary circulation. In contrast, the two-compartment model of Guyton et al. (15) and the multiple-circuit model proposed by Sylvester et al. (31) can address this issue. These studies, however, went no further than a theoretical analysis and remain insufficient for clinical application. The two-compartment model of Guyton et al. is complicated. It fails to express venous return curves parametrically; consequently, neither the stressed blood volume nor the curve shifts in response to changes in stressed blood volume can be estimated (15). Sylvester et al. (31) integrated systemic and pulmonary venous return curves into a single curve and expressed it parametrically. However, extensive experimental validations of the model are needed. In addition, because the pressure axis of their integrated venous return curve was the weighted average of PRA and PLA, we were unable to uniquely determine their individual values from the equilibrium point in their diagram.
There have been serious debates among cardiovascular physiologists regarding cause-effect relations between CO/venous return and atrial pressure, i.e., which variable determines the others? Brengelmann (3), Levy (20), and Tyberg (33) argued that as CO increases, the venous reservoir is depleted (i.e., blood is translocated from the veins to the arteries), and, therefore, venous pressure (i.e., atrial pressure) decreases. In the heart, atrial pressure determines CO according to the Frank-Starling mechanism. In contrast, in response to the work of Levy, Guyton (14) commented that he considered CO and atrial pressures to be the effects, or dependent variables. Blood volume and the mechanical properties of the heart and vasculature, such as heart rate, ventricular contractility, and vascular resistance, are the cause. The CO curve or venous return curve discloses those properties through the relation between the flow and atrial pressures. As we demonstrated in Eq. 1, under a given stressed volume, venous return/CO and atrial pressure have a linear relation. In other words, once venous return is determined, atrial pressure is automatically determined and vice versa. Therefore, our framework is consistent with Guyton's comment on the work of Levy. As far as the prediction of hemodynamics is concerned, however, the difference between their interpretations and ours does not impact the result of this study, because we are able to obtain the same equilibrium point with either interpretation (14, 20).
Application of This Framework
Accurate predictions of CO and filling pressures after therapeutic interventions are vital in the management of heart failure, as suggested by the classification of Forrester (10) and other previous studies (11, 21). Although the Swan-Ganz catheter allows us to estimate CO and filling pressures, such devices do not allow us to estimate the venous return curve or mean circulatory filling pressure (6). In contrast, because the parameter values of the venous return surface were invariable among animals, it is conceivable that the same standard values obtained from this investigation might be used for patients. If this is the case, for given values of CO, PLA, and PRA, all of which can be easily obtained by Swan-Ganz catheters, we can uniquely define the venous return surface and estimate stressed blood volume of patients without the need to perform total heart bypass (6). The clinical usefulness of knowing the venous return surface would be markedly increased if the integrated CO curve could be estimated. This would enable accurate prediction of the CO, PRA, and PLA in response to various therapeutic interventions, which induce changes in loading condition, or changes in the pumping ability of the heart, i.e., changes in CO curves. These should help optimize hemodynamic management and improve patient prognosis (10, 21).
Limitations
In this investigation, we isolated baroreceptors and fixed the autonomic tone. This was necessary, because the baroreflex alters the CO curve and venous return surface through its effects on stressed blood volume, vascular resistance, heart rate, and cardiac contractility (9, 24, 27). How changes in autonomic tone under the closed-loop condition affect the CO curve and venous return surface remains to be investigated.
We assumed that there is no fluid shift between the intravascular and extravascular space and that the volume perturbations exclusively changed the stressed blood volume. We assumed that the changes of cardiac volume and volume shifts between the heart and vasculatures are rather small. However, this may not be the case if the ventricles are extremely compliant, as in those with extensive remodeling (32). In such cases, the volume shifts between the heart and the vasculatures become significant. Further studies are required to clarify these relations to facilitate the future clinical application of this framework.
All the experiments of this study were conducted in anesthetized, open-chest dogs. Anesthesia and surgical trauma affect the cardiovascular system significantly (34). Whether this equilibrium framework can be applied to conscious, closed-chest animals (including humans) remains to be seen. We used two pumps for total heart bypass. However, it is well known that the CO of the two sides of the heart is not identical because of the anatomic shunt between the systemic and pulmonary circulations, e.g., the bronchial artery. However, the difference between the flow rates was <3% of CO. Therefore, it is unlikely that such a minor difference in CO would influence the conclusion of this study.
Conclusion
We were able to characterize the venous return properties of the systemic and pulmonary circulations in a simple manner using the flat venous return surface. Equating the standard venous return surface with the measured integrated CO curves, under a variety of stressed blood volumes and cardiac functions, enabled us to accurately predict hemodynamics.
| APPENDIX |
|---|
|
|
|---|
Using a distributed model, Sagawa and Sunagawa and their co-workers (24, 30) modeled the vascular system. Suppose that compliance and resistance are distributed in the systemic circulation (Fig. 10). When the compliance distribution [C(x)] and pressure distribution [P(x)] are expressed as a function of distance (x) from the venous port, then stressed blood volume (VS) in the systemic circulation can be described as
![]() | (A1) |
![]() | (A2) |
|
![]() | (A3) |
When CSDCS(x) is substituted for C(x), where CS is the total systemic vascular compliance and DCS(x) is the normalized distribution of compliance as a function of x (thus
0LDCS(x)dx is unity), Eq. A3 can be rewritten as
![]() | (A4) |
The first integral term, which sums cumulative resistance weighted by systemic compliance distribution, is equivalent to the resistance for systemic venous return, RVS, of Guyton et al. (16, 17). Because the second integral is unity, Eq. A4 can be rewritten as
![]() | (A5) |
Stressed blood volume in the pulmonary circulation (VP) can be related to COV and PLA by the following equation
![]() | (A6) |
For a given condition, the sum of the stressed blood volumes in the systemic circulation and pulmonary circulation, V (i.e., Vs + VP), remains constant, irrespective of its distribution. Thus adding Eqs. A5 and A6 and rearranging yields
![]() | (A7) |
![]() | (A8) |
![]() | (A9) |
![]() | (A10) |
For a given V, COV can be related to PRA and PLA by a surface expressed by Eq. A7 (Fig. 1B). When V is kept constant, COV decreases with increases in PRA and/or PLA.
From Eqs. A8A10, once CS, RVS, CP, and RVP are given, we can estimate W, GS, and GP. Lee and Goldman (19) reported CS as 1.9 ml·mmHg1·kg1 and RVS as 0.056 mmHg·ml1·min·kg in eight dogs. Shoukas (26) reported CP as 0.31 ml·mmHg1·kg1 and RVP as 0.077 mmHg·ml1·min·kg in nine dogs. Estimated W, GS, and GP were 0.131 min, 14.56 ml·min1·mmHg1·kg1, and 2.39 ml·min1·mmHg1·kg1, respectively. These values are in good agreement with those obtained in our experiment.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
K. Uemura, A. Kamiya, I. Hidaka, T. Kawada, S. Shimizu, T. Shishido, M. Yoshizawa, M. Sugimachi, and K. Sunagawa Automated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute decompensated heart failure J Appl Physiol, April 1, 2006; 100(4): 1278 - 1286. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-J. Wang, J. A. Flewitt, N. G. Shrive, K. H. Parker, and J. V. Tyberg Systemic venous circulation. Waves propagating on a windkessel: relation of arterial and venous windkessels to systemic vascular resistance Am J Physiol Heart Circ Physiol, January 1, 2006; 290(1): H154 - H162. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Uemura, T. Kawada, A. Kamiya, T. Aiba, I. Hidaka, K. Sunagawa, and M. Sugimachi Prediction of circulatory equilibrium in response to changes in stressed blood volume Am J Physiol Heart Circ Physiol, July 1, 2005; 289(1): H301 - H307. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK |