Am J Physiol Heart Circ Physiol 288: H1598-H1603, 2005.
First published November 18, 2004; doi:10.1152/ajpheart.01103.2003
0363-6135/05 $8.00
Dynamics of flow velocities in endocardial and epicardial coronary arterioles
Eiji Toyota,1
Yasuo Ogasawara,1
Osamu Hiramatsu,1
Hiroyuki Tachibana,1
Fumihiko Kajiya,1,2
Shinji Yamamori,3 and
William M. Chilian4
1Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Kurashiki, Okayama; 2Department of Physiology II, Okayama University Medical School, Shikata-cho, Okayama-shi, Okayama; 3Sensor Division, Engineering Operations, Nihon Kohden Corporation, Nishiochiai Shinjuku-ku, Tokyo, Japan; and 4Department of Physiology, Louisiana State University Health Sciences Center, New Orleans, Louisiana
Submitted 20 November 2003
; accepted in final form 12 November 2004
 |
ABSTRACT
|
|---|
The subendocardium is the most vulnerable area of the left ventricle to the effects of hypoperfusion and ischemia. Despite this well-acknowledged observation, the mechanisms underlying this susceptibility are not elucidated, although numerous explanations including differences in transmural distribution of hemodynamics, metabolism, and wall stresses have been proposed. Our goal was to make dynamic measurements of endocardial and epicardial flow velocities, which reflect hemodynamic and wall stresses, to approach this problem. We measured blood flow velocities in subendocardial and subepicardial coronary arterioles of in vivo beating canine hearts using a high-speed, charge-coupled device, intravital videomicroscope with a rod-probe lens. Subendocardial flow was characterized by remarkable systolic flow-velocity reversal (systolic slosh ratio, 84%; measurable velocity of retrograde flow, faster than 40 mm/s), which contrasted to predominant forward-flow velocity during systole in the subepicardial arterioles (systolic slosh ratio, 25%; maximum velocity, approximately 20 mm/s; P < 0.0005 and 0.05 vs. subendocardial arterioles, respectively). We speculate that this retrograde flow is "wasteful," because this volume must be refilled during the subsequent diastole, which thereby detracts from the net perfusion as well as the time for perfusion. Accordingly, we also believe that the retrograde systolic blood flow contributes to the vulnerability of the subendocardium to ischemia.
microcirculation; circulation; rheology; ischemia
THE SUBENDOCARDIUM IS THE most vulnerable area of the left ventricle to the effects of hypoperfusion and ischemia largely because of reduced autoregulatory reserve compared with the subepicardium, but the underlying mechanisms for these transmural differences of vulnerability and susceptibility to coronary hypoperfusion are unresolved (5, 10). Many factors have been speculated as contributing to this difference including differential distribution of coronary resistances in the subepicardial and subendocardial microcirculations (2), layer-dependent vascular volume reduction with architectural change by cardiac contraction (7, 27), wall stresses (31), metabolism (28), and arteriolar regulation (3, 19). However, none of these explanations has been unequivocally accepted or refuted. Despite historical appreciation for the relationship between cardiac contraction and coronary flow by Scaramucci in 1696 (23) and the speculated relationship to date of subendocardial retrograde flow to its vulnerability to ischemia by several investigators (4, 6, 1215, 21, 22, 24), differential amounts of retrograde flow occurring in subepicardial and subendocardial arterioles during systole have not been used to explain the subendocardial vulnerability to ischemia, because direct observation of retrograde flow in subendocardium has not been evident.
We reason that the amount of subendocardial blood retrograde flow may be an important consideration, because in some respects, it is a wasteful flow, a so-called "slosh," that reflects a volume that must be refilled during the subsequent diastolic antegrade flow (17). Thus measurement of flow velocities in coronary arterioles in the subendocardium and subepicardium during the cardiac cycle is a fundamental resolution for this question.
 |
METHODS
|
|---|
Animal preparation.
Experimental procedures and protocol were conducted according to the institutional guidelines approved by the Animal Research Committee of Kawasaki Medical School (nos. 95013, 96003, and 97058). Adult mongrel dogs (n = 25) of either sex that weighed 1832 kg were fully anesthetized with pentobarbital sodium (30 mg/kg iv) and ventilated by a respirator pump (model VS600; Instrumental Development). ECGs were recorded from standard limb leads, and a pressure catheter (model SPC-784A; Millar) was inserted via the right carotid artery to measure the aortic and left ventricular (LV) pressures. After median sternotomy and left thoracotomy were performed, the heart was exposed, supported in a pericardial cradle, and paced at 120 beats/min via atrial pacing. A diagonal branch of the left anterior descending artery (LAD) was catheterized for intracoronary injection of the microflow tracers. Coronary blood flow (CBF) of the LAD was measured using a transit-time ultrasonic flowmeter (model T206; Transonic Systems). Systemic hemodynamics and CBF were recorded on a data recorder (LabView 3.1.1; National Instruments Japan; Tokyo). As the experiment was completed, each dog was killed by induction of fibrillation after additional administration of pentobarbital sodium.
High-speed, charge-coupled device, intravital videomicroscope.
To make measurements of microvascular flow velocities (frame-by-frame movement of the tracers), we used a high-speed, charge-coupled device (CCD), intravital videomicroscope system (model MU925S-11; Nihon Kohden; Tokyo; Fig. 1). In this camera, the CCD image sensor has 130,000 pixels, a visual field of 1.04 x 0.80 mm2, a spatial resolution of 3.9 µm for the x20 objective with relay lenses, and a temporal resolution of 5 ms. The maximum measurable velocities are 160 and 210 mm/s vertically and horizontally, respectively.

View larger version (35K):
[in this window]
[in a new window]
|
Fig. 1. Schematic diagram of rod-probe, high-speed charge-coupled device (CCD), intravital videomicroscope. Measurements of diameter and flow velocity were obtained in subendocardial coronary arterioles at the midportion of the intraventricular septum and subepicardial arterioles in the left ventricular (LV) anterior free wall. These measurements from arterioles in the different areas of the ventricles were made during separate experiments. A/D, analog-to-digital converter; VCR, video cassette recorder.
|
|
The rod probe (diameter, 6.5 mm; length, 170 mm) contains relay lenses surrounded by 18 annular optical light fibers. The field is illuminated by visible light (a metal, halogen, 160-W lamp) through the light fibers. Images focused on the CCD are converted into gray scale video signals every 5 ms and are continuously stored for 1,024 frames in the digital buffer memories (128 MB). The optional high-speed video signals are generated as standard National Television System Committee signals with 30 frames/s by slow playback to record on the standard 8-mm video format. A doughnut-shaped balloon on the sheath tip prevents direct compression of the observed area (9, 29, 30). The blood within the space between the probe tip and the object surface is flushed away by warmed (37°C) saline injected through a microtube of the sheath.
Measurements of blood flow velocity and diameter.
The rod probe of the CCD camera was introduced onto the LV endocardial surface at the midportion of the intraventricular septum via the mitral valve to visualize subendocardial coronary arterioles. In separate experiments, the probe was positioned on the heart surface to make measurements in the subepicardial arterioles. As indicated by the focus range of the camera, arterioles were located at depths between 0 and 250 µm from both endo- and epicardial surfaces. The sizes of the arterioles were 35160 µm in subendocardium and 50155 µm in subepicardium. After identification of a suitable field (straight segments) within visible arterioles, microflow tracers were administrated (0.8-ml intracoronary bolus) and followed by a saline flush (2 ml). This tracer administration occurred only once per experiment. Flow-velocity measurements were restricted to the first several cardiac cycles after administration of the tracer bolus. Microflow tracers (lot 5010; Sekisui; Aichi, Japan; Ref. 20) had the following characteristics: diameter, 15.3 ± 2.2 µm; specific gravity, 1.36; consisting of fine (0.2 µm) particles of zirconium that reflect halogen light to facilitate visualization. The microflow tracers (48 x 106 particles/ml) were suspended in 0.09% sodium lauryl sulfate (Nacalai Tesque; Kyoto).
Among the flow tracers appearing in the vessels, tracers of the highest speeds (likely those in the center of the flow stream) were used to calculate flow velocity. Each tracer in the target arteriole was tagged, and its coordinate (center of tracer) was measured frame by frame (Fig. 2). Flow velocity was then calculated after correction for tissue movement from reference points; i.e., vascular bifurcation and/or solitary, embolized tracers. Phases of the cardiac cycle were precisely identified by referring to the ECG and aortic pressure waveforms on the high-speed image monitor in real time, and each calculated velocity value was placed in the context of the cardiac cycle. Velocities slower than 50 mm/s were considered as reliable, because tracer images faster than that were subject to some image distortion. Finally, the intervals of the fastest velocities at each phase were interpolated by spline function. The flow-velocity waveform during systole was divided into two components, namely, the systolic reverse-flow velocity component (SR) and the systolic forward-flow velocity component (SF). Values for the systolic slosh ratio, which was calculated as SR area/(SF area + SR area), were compared between subendocardial and subepicardial sites.

View larger version (36K):
[in this window]
[in a new window]
|
Fig. 2. Images of the subendocardial coronary arterioles with flowing microflow tracers in the beating canine heart. Time sequences of the images are displayed from top to bottom (5 ms/frame). Same tracer (arrow) shows deceleration of forward flow at the beginning of systole (top four photos), then flow cessation, and then a change to backward flow (bottom three photos). Bar indicates 250 µm (analyzed maximal distance for tracer movement per frame). R, R wave on ECG.
|
|
Phasic diameter measurements of arterioles were obtained offline, frame by frame, using an automatic analysis program (NIH Image 1.61) as we have previously described (9, 29, 30). Pulsation amplitude values (in percent) of the arterioles in the cardiac cycle were analyzed as [(diastolic diameter systolic diameter)/diastolic diameter] x 100.
Measurements of velocity (slower than 50 mm/s) and diameter were performed independently by two experts. Measurement accuracy was established by ascertaining the interobserver differences for several randomly selected frames. The correlation coefficients for the velocity and diameter values were 0.92 and 0.95, respectively.
Statistical analysis.
Data are expressed as means ± SE. Comparisons of systolic slosh ratios and pulsation amplitudes between subendocardial and subepicardial arterioles were performed by unpaired t-test. Statistical significance was set at P < 0.05.
 |
RESULTS
|
|---|
All hemodynamic variables and CBF values obtained during the measurements were as follows: aortic pressures, 110.1 ± 14.8/84.8 ± 20.6 mmHg; systolic LV pressure, 124.9 ± 8.5 mmHg; LV end-diastolic pressure, 12.2 ± 8.9 mmHg; heart rate, 118.3 ± 6.1 beats/min; and mean CBF, 33.8 ± 16.0 ml/min.
Figure 2 shows images of subendocardial coronary arterioles with flow-velocity tracers. Six samples of subendocardial flow velocity and diameter change were calculated. An example of tracings from subendocardial arterioles (Fig. 3, top) revealed inflow predominance during diastole and reverse flow during systole. In the other five cases, diastolic velocity exceeded 50 mm/s and could not be measured using our technique. Therefore, we focused on velocity patterns during systole (Fig. 4, top). Often we observed two components of reverse flow: one during early systole and a second during late systole. Six samples of subepicardial coronary flow revealed a diastolic predominance, and furthermore, a larger component of systolic forward flow (Figs. 3 and 4, bottom).

View larger version (30K):
[in this window]
[in a new window]
|
Fig. 3. An example of tracings of the flow-velocity waveforms and vascular diameter changes of the subendocardial (top) and subepicardial (bottom) arterioles. These samples were rare but enabled us to observe maximum forward- and reverse-flow velocities throughout the cardiac cycle. Note the difference in pattern of the waveforms. During systole, subendocardial flow was characterized by retrograde flow with less forward flow and was accompanied by a decrease in vascular diameter. Subepicardial flow was characterized by predominant systolic forward flow, a small component of reverse flow, and a small change in diameter.
|
|

View larger version (28K):
[in this window]
[in a new window]
|
Fig. 4. Examples of systolic flow-velocity waveforms and diameter changes of the subendocardial and subepicardial coronary arterioles. These were focused on systolic phase, because diastolic velocity was off the scale. Systole is indicated by the period between two dashed lines within the graphs. Massive retrograde flow was observed during systole in subendocardial arterioles, whereas a smaller reverse-flow component was observed in subepicardial arterioles.
|
|
In subendocardial arterioles, a significant amount of flow was retrograde during systole; systolic slosh ratio was 84.2 ± 8.0% (Table 1). This contrasts with the subepicardial arterioles (ratio, 24.6 ± 7.9%), which was significantly smaller than in the subendocardium (P < 0.0005). In both sites, maximum diastolic flow velocities were not measurable because they were off the scale. Measurable velocity of systolic reverse flow in subendocardium (41.1 ± 5.8 mm/s) was higher than in subepicardium (19.8 ± 6.6 mm/s; P < 0.05). The pulsation amplitudes of diameter in subendocardial and subepicardial arterioles were 24.5 ± 8.7 and 2.6 ± 4.4%, respectively (P < 0.05); this is consistent with our previous report (29).
View this table:
[in this window]
[in a new window]
|
Table 1. Comparison of systolic reverse flow and decrease in diameter between subendocardial and subepicardial arterioles
|
|
 |
DISCUSSION
|
|---|
In the present study, we directly compared subepicardial and subendocardial coronary arteriolar dynamics during the cardiac cycle to better understand the possible mechanisms that underscore vulnerability of the subendocardium to coronary hypoperfusion. We observed a substantial component of systolic retrograde flow velocity in the subendocardial arterioles that was much larger than in the subepicardium. This phenomenon has been hypothesized in many previous studies (47, 10, 12, 18, 25), but the present study confirmed this hypothesis as the first systemic evaluation. The volume of retrograde flow represents an amount that must be refilled during the subsequent diastolic period and thus detracts from overall antegrade perfusion in the subendocardium. This effect of contraction on subendocardial flow may contribute to the vulnerability of this region to coronary hypoperfusion (11). In this manner, as coronary reserve is diminished, the ability of the subendocardial vasculature to dilate as compensation for the loss of flow is hampered because of the retrograde pumping (2). Thus we believe our data provide important insight into the cause of subendocardial vulnerability to ischemia.
Mechanisms of retrograde flow from endocardium to epicardium can be explained by transmural differences in cardiac contraction. In early systole (during LV pressure development), the difference in the systolic flow pattern between both layers is well explained by the intramyocardial pump model (25). Direct measurements of intramyocardial pressure in the beating canine heart showed that the systolic intramyocardial pressure-to-LV pressure ratio decreased linearly from endocardium to epicardium (8). Accordingly, the intramyocardial blood inflow volume that occurred during diastole was squeezed out retrogradely.
Reverse flow in the later phase of systole has been explained by the time-varying elastance model (18). The elastance model predicts that retrograde pumping occurs because of time-varying elastance during the cardiac cycle, which is highest at the end of systole. Our results further refine these ideas. Specifically, we predict that because of the lower perfusion pressures in the subendocardium (2), the effects of elastance would be greatest in this region and would lead to higher retrograde systolic flow than in the subepicardium. We speculate that enhancement of late-systolic retrograde flow would be observed under pronounced hyperkinetic status and also during hypoperfusion.
Another factor that possibly influenced our results is that the arterioles in the endocardium are located at the most inner layer of the myocardial wall. Although these vessels are not embedded in the myocardium, they are situated on the endocardial surface and are likely affected by LV pressure. Their phasic diameters would also reflect influences imposed on the feeder and drainage vessels that are imbedded in the intramyocardial musculature in close proximity to the endocardial surface. Another factor that may produce retrograde flow in the arterioles at the subendocardial surface is myocardial strain. Kimura et al. (16) demonstrated drastic systolic flow deceleration in the atrium, where intramyocardial pressure linked to atrial pressures is low, so that myocardial deformation is a candidate. Partition of the influences of LV pressure, intramyocardial pressure, and myocardial strain in the mechanism(s) of this flow reversal is not yet elucidated; however, endocardial vessels likely represent a suitable model for studying the interactions of contraction with microvascular hemodynamics.
Another interesting finding of the present study was observed during the presystolic phase. Flow-velocity deceleration started immediately before the R wave on the standard limb-lead ECG, and this deceleration led to flow reversal in early systole. Ashikawa et al. (1) also reported the same abrupt decline and momentary reverse flow in epicardial small arterioles during the preejection period. The mechanism of the deceleration at this phase is unclear, although an increase in end-diastolic LV pressure by atrial kick, LV stretch by atrial kick, and LV myocardial deformation are candidates. Taken together, cardiac phase-dependent mechanisms and the partitioning of 1) LV pressure, 2) intramyocardial pressure, 3) elastance, and 4) myocardial deformation resulting in systolic flow reversal are still not elucidated.
In the subepicardium, we observed a fraction of systolic retrograde flow in most of the preparations (Fig. 4, bottom). This component is normally concealed by the capacitance of the extramural superficial coronary arteries (26).
Limitations of the study.
With the specifics of our system and the characteristics of the rod-probe microscope, we have found that 15-µm-diameter, zirconium microflow tracers are ideal for our application, because they are very reflective and thus are easily visualized. However, we would like to mention the possibility that the flow tracer could affect arteriolar flow dynamics by embolization, because the tracer is larger in diameter than the capillaries. To minimize this potential complication, tracers were administered once per experiment and were not repeated. Flow-velocity values during the first few seconds (when the tracers appeared) were equivalent to those measured toward the end of the sequence. If embolization was severe, there should have been a progressive reduction in velocity during the sequence; but this was not observed. Smaller tracers (diameter, 4 µm) of the same material flowing in the blood vessels were too dim to visualize. Furthermore, our preliminary studies taught us that 0.8 ml of a flow tracer of 48 x 106 particles/ml (thus 3.26.4 x 106 as the total number of particles) was the minimum number to be used to obtain a reliable velocity waveform line by spline plotting. Nevertheless, we believe it is fair to compare flow waveforms between subendocardial and subepicardial arterioles that are evaluated by an identical dose of flow tracer.
A doughnut-shaped balloon on the probe tip was used to keep a space between the cardiac surface and the probe lens, and it functioned as a cushion to avoid compression around the observed vessels. This became more effective by smooth-probe manipulation by well-trained experts, who could synchronize probe movements with heart beats. The construction and procedures of the present system were basically the same as those we used with our previously developed intravital videomicroscope (9, 29, 30) but newly loaded with a high-speed CCD camera. The original article (29) describing use of the previous system demonstrated that less difference in pressure waveform value was observed between the inner space of the balloon and the outer space (intra-LV cavity) during observation of the subendocardial vessels, which indicated that compression on observed vessels was negligible. Although we may not perfectly exclude any compressions, we believe it is fair to compare velocity and diameter values between subepicardium and subendocardium that are observed by identical manipulation.
Our microscope has a 6.5-mm-diameter rod-probe lens. This probe was inserted from the left appendage and through the mitral valve of an in vivo beating heart to visualize subendocardial flow. Probe insertion sometimes affected systemic hemodynamics depending on the heart size and the location of target arterioles. Nevertheless, under these conditions, arterioles in the subendocardium showed more enhanced systolic retrograde flow compared with the subepicardium, where flow was observed without any alterations in LV contractility.
Although the slosh ratio was calculated as the area under the curve of measurable velocity, we may have underestimated the magnitude because of technical limitations in our system. We could not measure velocities greater than 50 mm/s; thus our measurements have some error. Nevertheless, we believe our conclusion that enhanced slosh occurs in subendocardial vs. subepicardial arterioles.
In conclusion, we succeeded in visualizing the subendocardial coronary arteriolar dynamics and measuring diameter and flow velocity of in vivo beating canine hearts using our newly developed rod-probe, high-speed CCD, intravital videomicroscope. Prominent retrograde flow, the "coronary slosh phenomenon" in the subendocardium, may be the basis of subendocardial vulnerability to ischemia and hypoperfusion.
 |
GRANTS
|
|---|
This study was supported by Grants-In-Aid 09558125 and 008558103 for Scientific Research from the Ministry of Education, Science, Sport, and Culture.
 |
FOOTNOTES
|
|---|
Address for reprint requests and other correspondence: E. Toyota, Dept. of Cardiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, Okayama 701-0192, Japan (E-mail: etoyota{at}med.kawasaki-m.ac.jp)
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
 |
REFERENCES
|
|---|
- Ashikawa K, Kanatsuka H, Suzuki T, and Takishima T. Phasic blood flow velocity pattern in epimyocardial microvessels in the beating canine left ventricle. Circ Res 59: 704711, 1986.[Abstract/Free Full Text]
- Chilian WM. Microvascular pressures and resistances in the left ventricular subepicardium and subendocardium. Circ Res 69: 561570, 1991.[Abstract/Free Full Text]
- Chilian WM, Kuo L, DeFily DV, Jones CJ, and Davis MJ. Endothelial regulation of coronary microvascular tone under physiological and pathophysiological conditions. Eur Heart J 14, Suppl I: 5559, 1993.
- Chilian WM and Marcus ML. Phasic coronary blood flow velocity in intramural and epicardial coronary arteries. Circ Res 50: 775781, 1982.[Abstract/Free Full Text]
- Feigl EO. Coronary physiology. Physiol Rev 63: 1205, 1983.[Abstract/Free Full Text]
- Flynn AE, Coggins DL, Goto M, Aldea GS, Austin RE, Doucette JW, Husseini W, and Hoffman JI. Does systolic subepicardial perfusion come from retrograde subendocardial flow? Am J Physiol Heart Circ Physiol 262: H1759H1769, 1992.[Abstract/Free Full Text]
- Goto M, Flynn AE, Doucette JW, Jansen CM, Stork MM, Coggins DL, Muehrcke DD, Husseini WK, and Hoffman JI. Cardiac contraction affects deep myocardial vessels predominantly. Am J Physiol Heart Circ Physiol 261: H1417H1429, 1991.[Abstract/Free Full Text]
- Heineman FW and Grayson J. Transmural distribution of intramyocardial pressure measured by micropipette technique. Am J Physiol Heart Circ Physiol 249: H1216H1223, 1985.[Abstract/Free Full Text]
- Hiramatsu O, Goto M, Yada T, Kimura A, Tachibana H, Ogasawara Y, Tsujioka K, and Kajiya F. Diameters of subendocardial arterioles and venules during prolonged diastole in canine left ventricles. Circ Res 75: 393397, 1994.[Abstract/Free Full Text]
- Hoffman JI. Transmural myocardial perfusion. Prog Cardiovasc Dis 29: 429464, 1987.[CrossRef][ISI][Medline]
- Hoffman JI. Why is myocardial ischaemia so commonly subendocardial? Clin Sci (Lond) 61: 657662, 1981.[Medline]
- Iwanaga S, Ewing SG, Husseini WK, and Hoffman JI. Changes in contractility and afterload have only slight effects on subendocardial systolic flow impediment. Am J Physiol Heart Circ Physiol 269: H1202H1212, 1995.[Abstract/Free Full Text]
- Kajiya F and Goto M. Integrative physiology of coronary microcirculation. Jpn J Physiol 49: 229241, 1999.[CrossRef][ISI][Medline]
- Kajiya F, Ogasawara Y, Hiramatsu O, Tachibana H, Goto M, and Yada T. The relationship between cardiac contraction and intramyocardial hemodynamics. IEEE Eng Med Biol Mag 16: 127132, 1997.[CrossRef][ISI][Medline]
- Kajiya F, Yada T, Matsumoto T, Goto M, and Ogasawara Y. Intramyocardial influences on blood flow distributions in the myocardial wall. Ann Biomed Eng 28: 897902, 2000.[CrossRef][ISI][Medline]
- Kimura A, Hiramatsu O, Wada Y, Yada T, Yamamoto T, Goto M, Ogasawara Y, Tsujioka K, and Kajiya F. Atrial contractility affects phasic blood flow velocity of atrial small vessels in the dog. Cardiovasc Res 26: 12191225, 1992.[Abstract/Free Full Text]
- Kimura A, Hiramatsu O, Yamamoto T, Ogasawara Y, Yada T, Goto M, Tsujioka K, and Kajiya F. Effect of coronary stenosis on phasic pattern of septal artery in dogs. Am J Physiol Heart Circ Physiol 262: H1690H1698, 1992.[Abstract/Free Full Text]
- Krams R, Sipkema P, and Westerhof N. Varying elastance concept may explain coronary systolic flow impediment. Am J Physiol Heart Circ Physiol 257: H1471H1479, 1989.[Abstract/Free Full Text]
- Kuo L and Chancellor JD. Adenosine potentiates flow-induced dilation of coronary arterioles by activating KATP channels in endothelium. Am J Physiol Heart Circ Physiol 269: H541H549, 1995.[Abstract/Free Full Text]
- Mori H, Haruyama S, Shinozaki Y, Okino H, Iida A, Takanashi R, Sakuma I, Husseini WK, Payne BD, and Hoffman JI. New nonradioactive microspheres and more sensitive X-ray fluorescence to measure regional blood flow. Am J Physiol Heart Circ Physiol 263: H1946H1957, 1992.[Abstract/Free Full Text]
- Mori H, Tanaka E, Hyodo K, Uddin Mohammed M, Sekka T, Ito K, Shinozaki Y, Tanaka A, Nakazawa H, Abe S, Handa S, Kubota M, Tanioka K, Umetani K, and Ando M. Synchrotron microangiography reveals configurational changes and to-and-fro flow in intramyocardial vessels. Am J Physiol Heart Circ Physiol 276: H429H437, 1999.[Abstract/Free Full Text]
- Morita K, Mori H, Tsujioka K, Kimura A, Ogasawara Y, Goto M, Hiramatsu O, Kajiya F, and Feigl EO. Alpha-adrenergic vasoconstriction reduces systolic retrograde coronary blood flow. Am J Physiol Heart Circ Physiol 273: H2746H2755, 1997.[Abstract/Free Full Text]
- Scaramucci J. Theoremata familiaria viros eruditos consulentia de variis physico-medicis lucubrationibus juxta leges mecanicas. Urbino, Italy: Apud Joannem Baptistam Bustum, 1696, p. 7081.
- Spaan JA. Mechanical determinants of myocardial perfusion. Basic Res Cardiol 90: 89102, 1995.[CrossRef][ISI][Medline]
- Spaan JA, Breuls NP, and Laird JD. Diastolic-systolic coronary flow differences are caused by intramyocardial pump action in the anesthetized dog. Circ Res 49: 584593, 1981.[Free Full Text]
- Spaan JA, Breuls NP, and Laird JD. Forward coronary flow normally seen in systole is the result of both forward and concealed back flow. Basic Res Cardiol 76: 582586, 1981.[CrossRef][ISI][Medline]
- Toyota E, Fujimoto K, Ogasawara Y, Kajita T, Shigeto F, Matsumoto T, Goto M, and Kajiya F. Dynamic changes in three-dimensional architecture and vascular volume of transmural coronary microvasculature between diastolic- and systolic-arrested rat hearts. Circulation 105: 621626, 2002.[Abstract/Free Full Text]
- Weiss HR, Neubauer JA, Lipp JA, and Sinha AK. Quantitative determination of regional oxygen consumption in the dog heart. Circ Res 42: 394401, 1978.[Abstract/Free Full Text]
- Yada T, Hiramatsu O, Kimura A, Goto M, Ogasawara Y, Tsujioka K, Yamamori S, Ohno K, Hosaka H, and Kajiya F. In vivo observation of subendocardial microvessels of the beating porcine heart using a needle-probe videomicroscope with a CCD camera. Circ Res 72: 939946, 1993.[Abstract/Free Full Text]
- Yada T, Hiramatsu O, Kimura A, Tachibana H, Chiba Y, Lu S, Goto M, Ogasawara Y, Tsujioka K, and Kajiya F. Direct in vivo observation of subendocardial arteriolar response during reactive hyperemia. Circ Res 77: 622631, 1995.[Abstract/Free Full Text]
- Yin FC. Ventricular wall stress. Circ Res 49: 829842, 1981.[Free Full Text]
This article has been cited by other articles:

|
 |

|
 |
 
H. Ashikaga, B. A. Coppola, K. G. Yamazaki, F. J. Villarreal, J. H. Omens, and J. W. Covell
Changes in regional myocardial volume during the cardiac cycle: implications for transmural blood flow and cardiac structure
Am J Physiol Heart Circ Physiol,
August 1, 2008;
295(2):
H610 - H618.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. Westerhof, C. Boer, R. R. Lamberts, and P. Sipkema
Cross-talk between cardiac muscle and coronary vasculature.
Physiol Rev,
October 1, 2006;
86(4):
1263 - 1308.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. A. Rogers, T. Kiyooka, and W. M. Chilian
Is there a need for another model on the pulsatile nature of coronary blood flow?
Am J Physiol Heart Circ Physiol,
September 1, 2006;
291(3):
H1034 - H1035.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. Yalcin, F. Aydin, P. Ulker, M. Uyuklu, F. Gungor, J. K. Armstrong, H. J. Meiselman, and O. K. Baskurt
Effects of red blood cell aggregation on myocardial hematocrit gradient using two approaches to increase aggregation
Am J Physiol Heart Circ Physiol,
February 1, 2006;
290(2):
H765 - H771.
[Abstract]
[Full Text]
[PDF]
|
 |
|
Copyright © 2005 by the American Physiological Society.