Division of Critical Care Medicine, Department of Medicine, and Department of Physiology and Biophysics, Rosalind Franklin University of Medicine and Science, North Chicago; and Section of Critical Care Medicine, Medical Service, North Chicago Veterans Affairs Medical Center, North Chicago, Illinois
Submitted 24 November 2004 ; accepted in final form 5 February 2005
| ABSTRACT |
|---|
|
|
|---|
ventricular fibrillation; cardiopulmonary resuscitation; defibrillation; sodium-hydrogen antiporter; fluorescent microspheres
We recently reported that ischemic contracture can be minimized by inhibition of the Na+/H+ exchanger isoform-1 (NHE-1) using cariporide (4-isopropyl-methylsulfonylbenzoyl-guanidine methanesulfonate; Refs. 2, 13). We therefore reasoned that if cariporide can prevent ischemic contracture (thus preserving ventricular cavity size), it could lead to hemodynamically more efficient closed-chest resuscitation and thereby enable greater forward blood flow to be generated for a given depth of compression. To test this hypothesis, we used a rat model of ventricular fibrillation (VF) and closed-chest resuscitation in which systemic and regional blood flows were measured using fluorescence microspheres (15, 16, 30, 41, 42). The depth of chest compression was adjusted to attain predetermined aortic diastolic pressures in rats randomized to receive either cariporide or 0.9% NaCl immediately before chest compression was started.
| METHODS |
|---|
|
|
|---|
Animal preparation.
Twenty-eight adult male Sprague-Dawley rats (body wt, 477560 g) were anesthetized with pentobarbital sodium (loading dose, 45 mg/kg ip; maintenance dose, 10 mg/kg ip every 30 min). Core temperature was maintained between 36.5 and 37.5°C with an infrared heating lamp. A 5-Fr cannula was orally advanced into the trachea and used for positive-pressure ventilation during cardiac resuscitation and the postresuscitation interval. Proper placement was verified using an infrared CO2 analyzer (CO2SMO model 7100; Novametrix Medical Systems). A polyethylene (PE)-50 catheter was advanced through the right carotid artery into the left ventricle for measurement of pressure and injection of fluorescent microspheres. The tip of the catheter was positioned at 
4 mm from the aortic valve guided by pressure waveforms. Additional PE-50 catheters were advanced through the left femoral artery into the abdominal aorta for monitoring aortic pressure and through the right femoral artery into the descending thoracic aorta for blood withdrawal after injection of microspheres (reference organ). PE-50 catheters were also advanced through the left femoral vein into the right atrium for pressure measurement and through the right femoral vein into the inferior vena cava for blood infusion. A lead II ECG was recorded using subcutaneous needles. A 3-Fr catheter (C-PUM-301J; Cook) was advanced through the right external jugular vein into the superior vena cava, and a precurved guide wire was advanced through its lumen into the right ventricle. The guide wire was used for electrical induction of VF. A bolus of heparin sodium (600 IU/kg) was administered at the end of surgery to ensure patency of the aortic line used for the reference organ blood flow.
Systemic and organ blood flow measurements. Fluorescent microspheres (15 µm diameter; F21015 [GenBank] FluoSpheres; Molecular Probes; Eugene, OR) were used for blood flow measurement. Techniques previously reported (15, 16, 30, 41, 42) and described in detail by the Fluorescent Microsphere Resource Center (11) were adapted for measurements under the low-flow conditions of closed-chest resuscitation. Four fluorescent colors with spectrally distinct maximal excitation and emission wavelengths (green, yellow, red-orange, and carmine) were chosen for measurements at baseline, during chest compression, and at 15 and 60 min postresuscitation. The colors had sufficient spectral separation to minimize emission overlap (<1%) and fluorescence energy transfer. The sequence of colors was rotated after each experiment.
The number of microspheres injected was calculated to secure delivery of
400 microspheres to each adrenal gland (
0.03 g) according to Eq. 1. This number has previously been shown to provide 95% confidence that the flow measured is within 10% of the actual flow (6)
![]() | (1) |
o is the organ/tissue flow (in ml·min1·g1), and
T is the total flow (in ml/min).
Flow data from a previously reported rat model of closed-chest resuscitation were used for these calculations in which the approximate total and adrenal gland flow rates were 95 ml/min and 11 ml·min1·g1 at baseline and 11 ml/min and 1 ml·min1·g1 during chest compression (10). These calculations yielded a minimum requirement of
115,000 microspheres at baseline and
150,000 microspheres during chest compression.
Microspheres were stored protected from light at 4°C in sterile 10-ml multidose vials suspended in 0.15 M NaCl with 0.05% Tween 20 and 0.02% thimerosal. We injected 0.2 ml of the suspension (
200,000 microspheres) at baseline and 60 min postresuscitation and 0.3 ml (
300,000 microspheres) during chest compression and at 15 min postresuscitation.
Before injection, the vial containing the microspheres was ultrasonicated in a water bath for 5 min to break up aggregations and then vortexed for 2 min to prevent sedimentation. The volume to be injected plus 50 µl was withdrawn from the multidose vial using sterile technique and transferred to a 500-µl glass syringe (Hamilton, Fisher Scientific). The 50-µl aliquot was placed into a sample-processing unit (SPU; Kunstsoff-und Metallprodukte; Kappel-Grafenhausen, Germany), and the remaining volume was injected into the left ventricle over an interval of 30 s. The SPU is a tube-filtration device that includes a polyamide wire mesh and allows sample processing (digestion, filtering, and dye extraction) in a single container, thereby minimizing loss of microspheres (30). During injection, the LV pressure waveform was monitored continuously to verify proper intracavitary delivery of microspheres. Remnant microspheres were flushed into the ventricular cavity using heparinized saline. The precise amounts of the aliquot and injectate were determined by differential weight measurement using an analytical scale (Mettler Toledo; A. Diagger) with a precision of ±0.1 mg.
For the reference organ flow (see Eq. 2), blood was withdrawn from the descending thoracic aorta using a precision programmable syringe pump (model PHD 2000; Harvard Apparatus; Holliston, MA) at a constant rate of 0.5 ml/min (starting 1 min before microsphere injection) during spontaneous circulation and at 0.2 ml/min (starting 2 min before injection) during chest compression. The lower withdrawal rate during chest compression was possible given the lesser tracer dilution in low-flow states. The pressure in the withdrawal line was monitored continuously to verify uninterrupted blood withdrawal. Reference blood samples were also transferred to SPUs, and the remnant microspheres were flushed into the SPU using 0.02% Tween 80. In preliminary studies, dilution curves were constructed by measuring microsphere fluorescence in the reference organ at 30-s intervals. From these curves, we determined that collection times of 4.0 min during spontaneous circulation and 5.5 min during chest compression sufficed to sample >95% of the injected microspheres. An equal amount of blood from a same-colony donor rat was infused concurrently into the inferior vena cava.
The heart, brain, kidneys, and adrenal glands were removed after completion of the experiment and fixed in 10% formalin for 48 h. Organs were then freed from fatty and connective tissues. The atria and the right ventricle were removed, thereby isolating the left ventricle for processing. The cerebellum and midbrain were removed to isolate each cerebral hemisphere for processing. The kidneys and adrenal glands were processed intact. The samples or organs were weighed and placed in individual SPUs.
The samples were processed at the Institute for Surgical Research in Munich, Germany by Dr. Eckart Thein using a previously reported robotic processing system (42). The process entailed isolation of microspheres by tissue digestion and filtration and subsequent dissolution of microspheres in organic solvent to release the fluorescent dye. The fluorescence intensities measured in samples with equal solvent volumes (representing the total number of microspheres in the sample) were used to calculate the various rates of regional blood flow according to
![]() | (2) |
ref is the reference organ blood flow (in ml/min).
For cardiac output measurement, the organ/tissue of unknown flow becomes the whole body (total flow). Its fluorescence, which was determined from the injected microspheres, was calculated according to
![]() | (3) |
Cardiac output was calculated using Eq. 2 after substituting Finj for Fo.
Hemodynamic measurements. Signals were processed using signal conditioners (BIOPAC Systems), sampled at 250 scans/s, and digitized using a 16-bit data-acquisition board (model AT-MIO-16XE-50; National Instruments). Pressures were measured using disposable pressure transducers (Maxxim Medical) calibrated to zero at the midchest. The coronary perfusion pressure corresponded to the diastolic pressure difference between the aorta and right atrium. During chest compression, these pressures were measured at the end of chest relaxation.
Compression depth measurements. For the first series (see Experimental series), compression depth was measured at the end of the resuscitation protocol recording the maximum piston displacement. For the second series, a displacement transducer (DSPL; World Precision Instruments) was incorporated to enable continuous monitoring of piston displacement.
VF and resuscitation protocols.
VF was induced by delivering a 60-Hz alternating current to the right ventricular endocardium (1.06.0 mA) for an uninterrupted interval of 3 min (44). After 10 min of untreated VF, chest compression was started using an electronically controlled and pneumatically driven (50 psi) chest compressor (CJ-80623; CJ Enterprises) set to deliver 200 compressions/min with a duty cycle of 50%. Both the downstroke and upstroke piston displacements were pneumatically driven. The compression depth was gradually increased over an interval of 2 min to attain a predetermined aortic diastolic pressure (see Experimental series). The piston travel was then continuously adjusted to maintain this pressure target without exceeding a maximum displacement of 20 mm. Positive-pressure ventilation was provided using an electronically controlled solenoid valve (R-481; Clippard Instrument Laboratory) set to deliver 0.39 ml/100 g body wt of 100% oxygen every two compressions. Defibrillation was attempted at 8 min of chest compression by delivering a maximum of two 2-J monophasic transthoracic shocks (Lifepak 9P; Physio-Control). If VF persisted or an organized rhythm with a mean aortic pressure of
25 mmHg ensued, chest compression was resumed for 30 s. The defibrillation-compression cycle was repeated up to three additional times, increasing the energy of individual shocks (if VF persisted) to 4 J and then to 8 J for the last two cycles. Successful resuscitation was defined as the return of an organized cardiac rhythm with a mean aortic pressure of
60 mmHg for
5 min. Rats were monitored for a maximum of 120 min postresuscitation.
Experimental series. Two series were conducted, each of which included 14 rats. The depth of compression was adjusted to maintain a target aortic diastolic pressure between 26 and 28 mmHg in series 1 and between 36 and 38 mmHg in series 2. These levels promoted coronary perfusion pressures that exceeded the 20-mmHg threshold for successful resuscitation in rats (44). In both series, rats were randomized to receive a 3-mg/kg bolus of cariporide dissolved in 0.9% NaCl or an equal amount of 0.9% NaCl (control) into the right atrium immediately before chest compression was started. Cariporide (Aventis Pharma Deutschland) is a highly selective NHE-1 inhibitor with no apparent effects on the Na+/Ca2+ exchanger or fast Na+ currents at levels not exceeding 10 µmol/l (34).
Statistical analysis. Differences between groups for continuous variables were analyzed using one-way ANOVA. Alternative nonparametric tests were used if the data failed the tests for normality or equal variance. Categorical variables were analyzed using Fisher exact test. The data are presented as means ± SD unless stated otherwise. A two-tail value of P < 0.05 was considered significant.
| RESULTS |
|---|
|
|
|---|
24% lower than blood flow to the left cerebral hemisphere. Differences of varying magnitude persisted during chest compression and postresuscitation and were attributed to ligation of the right carotid artery needed for vascular access to the left ventricle. Depth of compression. Chest compression, which was started after the 10-min interval of untreated VF, gradually increased the aortic diastolic pressure and reached the target levels of 2628 mmHg in series 1 and 3638 mmHg in series 2 by minute 2 of chest compression. The compression depth required to maintain such levels was significantly less in rats treated with cariporide (Fig. 1). The effects on coronary perfusion pressure are shown in Fig. 2. In series 1, the coronary perfusion pressure remained stable throughout chest compression at levels that were similar in both groups. In series 2, a higher coronary perfusion pressure was initially generated as planned. However, numerical declines in coronary perfusion pressure that did not reach statistical significance were observed beyond minute 5 of chest compression in control rats despite continuous increases in the depth of compression (Fig. 3). The maximally allowed piston travel of 20 mm was reached in four control rats but in none of the cariporide-treated rats.
|
|
|
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Hemodynamic effects of chest compression. Control rats represented the very limited hemodynamic effects of present closed-chest resuscitation techniques. In series 1, the forward blood flow generated corresponded to only 7% of the baseline cardiac index and did not increase in series 2 despite a 14% increase in the depth of compression. Although higher aortic diastolic and coronary perfusion pressures were initially attained in series 2, maintenance of such pressure required progressive increases in the depth of compression that reached depths considered maximal in four of seven rats. We previously proposed that this phenomenon may in part be related to progressive development of ischemic contracture with consequent reductions in ventricular cavity size, preload, and the capability of chest compression to generate forward blood flow (2, 13). However, the need for deeper compressions may also originate from reductions in preload as a result of diminished venous return. To this end, full reexpansion of the chest cavity with creation of negative intrathoracic pressure between compressions is presently recognized as an important determinant of effective chest compression (36). However, with prolonged and deeper compressions, permanent chest wall deformation occurs, which potentially compromises elastic recoil and venous return (7). A detrimental vicious cycle can be envisioned in which the depth of compression is progressively increased in an attempt to offset declining forward blood flow as a result of ischemic contracture. Deeper compressions, in turn, disrupt the integrity of the chest wall and its resultant elastic recoil, further reducing venous return and erroneously signaling the need for greater depth of compression. As the hemodynamic effects of chest compression spiral down and the risk of laceration of intrathoracic structures increases, a situation arises in which successful resuscitation becomes exceedingly improbable.
Effect of cariporide. Cariporide fundamentally modified the hemodynamic response to chest compression. In series 1, cariporide allowed chest compression to promote systemic and regional blood flows of magnitude comparable to those in control rats but with significantly less depth of compression. In series 2, increases in depth of compression were accompanied by commensurate increases in systemic and regional blood flow. More importantly, higher flow rates were attained without having to progressively increase the depth of compression. Thus cariporide, by shifting the flow-depth relationship of chest compression to the left, enabled more effective and stable closed-chest resuscitation. The beneficial effects of cariporide most likely stemmed from amelioration of ischemic contracture and preservation of ventricular preload. Preservation of preload would allow higher rates of blood flow to be generated for a given depth of compression. It is also conceivable that part of the benefit resulted from refraining from maximally compressing the chest and thus preserving the integrity of the chest wall, its corresponding elastic recoil, and venous return.
The evidence that cariporide ameliorates ischemic contracture is based on observations in animal models of coronary occlusion and reperfusion by Garcia-Dorado and coworkers (12) and in models of VF and resuscitation by our group (2, 13). In our studies in an isolated rat heart model of VF, cariporide attenuated progressive increases in LV pressures during low-flow perfusion and prevented postischemic leftward shifts of the diastolic pressure-volume curve (13). In a pig model of VF in which the heart was imaged using transesophageal echocardiography, cariporide prevented progressive LV wall thickening and enabled hemodynamically more effective chest compression (2).
Mechanism of action. The precise cellular mechanism by which cariporide exerts its beneficial effects during resuscitation from VF is the subject of ongoing research. Consistent evidence from work in settings of ischemia and reperfusion other than cardiac arrest indicate that NHE-1 is activated by the profound intracellular acidosis that accompanies ischemia (1). NHE-1 activation prompts Na+ entry to cardiomyocytes in exchange for H+. However, because the Na+/K+ ATPase pump becomes disabled during ischemia (5), Na+ accumulates in the cytosol and drives Ca2+ entry through the sarcolemmal Na+/Ca2+ exchanger operating in its reverse mode (19, 21). Cytosolic and mitochondrial Ca2+ overload in conjunction with ATP depletion and oxidative stress would open the mitochondrial permeability transition pore and lead to mitochondrial swelling, depolarization, uncoupling of oxidative phosphorylation, and release of proapoptotic factors (17, 18). The beneficial effect of cariporide during myocardial ischemia and reperfusion is thought to result primarily from inhibition of NHE-1, thereby limiting Na+-induced cytosolic Ca2+ overload and subsequent mitochondrial Ca2+ overload (37, 38, 40). In addition, recent studies suggest that NHE-1 inhibitors may also have direct effects on mitochondrial ion-exchange mechanisms, increasing the threshold for opening of the mitochondria permeability transition pore (20). The extent to which these effects account for the beneficial effects observed during cardiac arrest needs further clarification.
Microspheres technique. Adequate mixing of microspheres in the bloodstream and proper sampling in the reference organ is critical to secure reliable measurement of blood flow. Although double-chamber mixing after left atrial injection is considered preferable to single-chamber mixing after LV injection, previous studies (6) have shown similar microsphere distribution after left atrial or LV injection. The comparable blood flows to paired organs (with the exception of cerebral hemispheres because of right carotid ligation) would support adequate mixing of microspheres after LV injection in the present studies. We also verified that microspheres were delivered into the left ventricle by visualizing in each instance the characteristic LV pressure waveform during injection, which is critical during chest compression when the LV catheter may be displaced out of the cavity. Systemic heparinization along with continuous pressure monitoring of the withdrawal line ensured uninterrupted collection of microspheres into the reference organ. We also secured in preliminary studies that adequate reference-organ collection times were allowed during spontaneous circulation and during chest compression. Incomplete collection would falsely overestimate blood flow. The very low flow rates measured during chest compression would argue otherwise. In addition, the cardiac indices measured during spontaneous circulation were highly comparable to those measured by thermodilution in separate experiments under essentially identical experimental conditions (128 at baseline, 63 at 15 min postresuscitation, and 65 ml·min1·kg1 at 60 min postresuscitation in 10 rats; unpublished data).
Limitations of study. The need for prolonged electrical stimulation to induce self-sustaining VF, the use of pentobarbital anesthesia, the relatively pliable chest wall of rats, and the absence of underlying cardiovascular disease limit extrapolation of the findings to larger animal models and humans. The rat model, however, has proven to be remarkably useful for developing new concepts in resuscitation research which have been reproduced in larger animal models of VF and resuscitation.
In addition, bolus administration of cariporide may yield blood levels that are substantially higher than those for which selectivity has been defined. We recently documented (unpublished) in a pig model of VF plasma levels of cariporide more than three orders of magnitude the concentration needed to completely inhibit NHE-1 activity in isolated cardiomyocytes (10 µmol/l) and fully protect the myocardium in isolated rat heart models of ischemia and reperfusion (1 µmol/l; Ref. 33) after bolus injection (3 mg/kg) into the right atrium during chest compression. These high levels would predict loss of isoform selectivity and inhibition of slowly inactivating Na+ currents (33, 43). However, no adverse effects were noted, and inhibition of slowly inactivating Na+ current may also contribute to myocardial protection during ischemia and reperfusion (26).
Clinical implications. Ultimate extension of these findings to clinical settings could have important implications for closed-chest resuscitation. Present techniques are not only limited by reduced hemodynamic efficacy but also by substantial risk of injury to the chest wall and intrathoracic viscera (24, 25, 31). Postmortem studies have shown a high incidence of rib fractures, sternal fracture, mediastinal hemorrhage, and life-threatening laceration of heart and great vessels. Thus enabling critical organ blood flow to be generated with less depth (force) of compression, minimizing chest wall injury, and preserving elastic recoil would be highly desirable. Previous work (2) on our pig model of VF supports the extension of these findings to a larger animal species. NHE-1 is known to be expressed in human myocardium (45), and NHE-1 inhibition has been shown to protect myocardium in patients undergoing coronary artery bypass grafting (Expedition trial, unpublished data).
We have previously reported (23) that NHE-1 inhibition enhances the effects of vasopressor agents during chest compression, ameliorates reperfusion arrhythmias, prevents refibrillation, and improves postresuscitation myocardial function (2, 13). The present studies strengthen the rationale of NHE-1 inhibition during cardiac resuscitation by demonstrating beneficial effects on the flow-depth relationship of chest compression.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. Radhakrishnan, I. M. Ayoub, and R. J. Gazmuri Activation of caspase-3 may not contribute to postresuscitation myocardial dysfunction Am J Physiol Heart Circ Physiol, April 1, 2009; 296(4): H1164 - H1174. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gautier, D. Antier, P. Bonnet, J.-L. L. Net, G. Hanton, and V. Eder Continuous inhalation of carbon monoxide induces right ventricle ischemia and dysfunction in rats with hypoxic pulmonary hypertension Am J Physiol Heart Circ Physiol, August 1, 2007; 293(2): H1046 - H1052. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Wang, J. Radhakrishnan, I. M. Ayoub, J. D. Kolarova, D. M. Taglieri, and R. J. Gazmuri Limiting sarcolemmal Na+ entry during resuscitation from ventricular fibrillation prevents excess mitochondrial Ca2+ accumulation and attenuates myocardial injury J Appl Physiol, July 1, 2007; 103(1): 55 - 65. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||