AJP - Heart AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 289: H263-H269, 2005. First published April 15, 2005; doi:10.1152/ajpheart.00060.2005
0363-6135/05 $8.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
289/1/H263    most recent
00060.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moriondo, A.
Right arrow Articles by Negrini, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moriondo, A.
Right arrow Articles by Negrini, D.

Transmural pressure in rat initial subpleural lymphatics during spontaneous or mechanical ventilation

Andrea Moriondo,1 Sylvain Mukenge,2 and Daniela Negrini1

1Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Università degli Studi dell'Insubria, Varese; and 2Dipartimento di Chirurgia, Ospedale San Raffaele, Milan, Italy

Submitted 20 January 2005 ; accepted in final form 15 March 2005


    ABSTRACT
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The role played by the mechanical tissue stress in supporting lymph formation and propulsion in thoracic tissues was studied in deeply anesthetized rats (n = 13) during spontaneous breathing or mechanical ventilation. After arterial and venous catheterization and insertion of an intratracheal cannula, fluorescent dextrans were injected intrapleurally to serve as lymphatic markers. After 2 h, the fluorescent intercostal lymphatics were identified, and the hydraulic pressure in lymphatic vessels (Plymph) and adjacent interstitial space (Pint) was measured using micropuncture. During spontaneous breathing, end-expiratory Plymph and corresponding Pint were –2.5 ± 1.1 (SE) and 3.1 ± 0.7 mmHg (P < 0.01), which dropped to –21.1 ± 1.3 and –12.2 ± 1.3 mmHg, respectively, at end inspiration. During mechanical ventilation with air at zero end-expiratory alveolar pressure, Plymph and Pint were essentially unchanged at end expiration, but, at variance with spontaneous breathing, they increased at end inspiration to 28.1 ± 7.9 and 28.2 ± 6.3 mmHg, respectively. The hydraulic transmural pressure gradient ({Delta}Ptm = Plymph – Pint) was in favor of lymph formation throughout the whole respiratory cycle ({Delta}Ptm = –6.8 ± 1.2 mmHg) during spontaneous breathing but not during mechanical ventilation ({Delta}Ptm = –1.1 ± 1.8 mmHg). Therefore, data suggest that local tissue stress associated with the active contraction of respiratory muscles is required to support an efficient lymphatic drainage from the thoracic tissues.

interstitial fluid pressure; tissue fluid homeostasis


INTERSTITIAL FLUID VOLUME reflects the balance between fluid filtration from the microvascular compartment and reabsorption through the initial lymphatic network. The efficiency of the interstitial fluid volume control is not uniform among the various tissues; in fact, whereas most soft tissues, such as subcutaneous, may withstand a certain degree of increased tissue hydration without significant functional loss, other tissues may suffer significant functional impairment as a consequence of fluid accumulation. The damaging effects of tissue edema are clearly evident in the lung parenchyma (20, 21), as well as in the pleural space; indeed, because the lung-chest wall mechanical coupling relies on intrapleural depression, an increased pleural fluid volume (and pressure) critically reduces lung expansion, thus affecting the overall efficiency of the respiratory system. The maintenance of pleural fluid volume mostly depends on the pleural lymphatics supplying the parietal pleura (8, 11, 12); indirect evidence (9, 10) suggests that lymphatic drainage is equally crucial for the lung parenchyma.

An important factor in enhancing lymphatic function is tissue movement, which determines cycles of external compression/expansion of the lymphatic vessel lumen. As a result, pressure gradients develop across the lymphatic vessel wall favoring both fluid entrance from the interstitium into the lymphatic lumen and/or progression of the newly formed lymph from one functional unit (lymphangion) to the next (1, 22). Hence, the composite effect of the cyclic cardiac and respiratory movements may actually play a significant role in enhancing lymphatic function in thoracic tissues.

Although the importance of the respiratory activity in pleural lymph formation has been demonstrated by indirect evidence (13), the mechanism through which the respiratory component of thoracic tissue movements acts on the lymphatic vessels remains at present unknown, mainly because of the experimental difficulties encountered in approaching the initial lymphatic system "in situ" in highly moving tissues. Therefore, the aim of the present research was to measure the hydraulic pressure in the initial lymphatics draining the thoracic tissues (Plymph) and in the adjacent intercostal interstitial space (Pint) during spontaneous breathing or passive lung inflation. The role of the tensile and/or compressive tissue stresses applied during active or passive chest expansion was evaluated on the basis of the net pressure gradients developing during the entire respiratory cycle across the lymphatic vessel wall.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The experiments were performed on 13 adult male rats [body weight 317 ± 10 (SE) g] in accordance with the guidelines of the Animal Care and Use Committee of the Ministry of University and Research. Rats were deeply anesthetized with 2.5 ml/kg body wt of an anesthetic cocktail of saline solution containing 0.25 g/ml urethane plus 10 mg/ml pentobarbital sodium and 0.03 mg/ml fentanyl. Subsequently, boluses of 0.1 ml of the anesthetic cocktail were given intravenously throughout the experiment to maintain deep and stable anesthesia, the level of which was assessed on the basis of the disappearance of the corneal reflexes. Once anesthetized, the animals were turned supine on a warmed (37°C) blanket; they were tracheotomized and left to breathe spontaneously through an intratracheal cannula.

Blunted-tipped saline-filled plastic catheters were inserted into a carotid artery and a jugular vein and were connected to physiological pressure transducers (model P23 XL; Gould Electronics). In addition, to measure esophageal pressure, a saline-filled PE50 catheter was advanced in the esophagus with its blunted tip positioned in correspondence with the second third of the sternum.

Systemic arterial, venous, and esophageal pressures were monitored throughout the whole experiment by conveying the pressure signal to an amplifier and a signal conditioner (model 6600; Gould Electronics). The signal was then digitized with an analog-to-digital board and displayed on the monitor screen using dedicated LabView software (National Instruments, Austin, TX).

A heated pneumotachograph (model 8420; Hans Rudolph) equipped with a dedicated pneumotach amplifier (model 1110A; Hans Rudolph) was connected to the tracheal cannula for continuous recording of respiratory flow. Tidal volume was obtained from integration of the respiratory flow signal performed with the LabView software.

Intravital labeling of intercostal pleural lymphatic network. The skin and the external intercostal muscles on the right side of the thorax were cleared to expose the ribs and the internal intercostal muscles. A stainless steel cannula (external diameter 0.7 mm; internal diameter 0.4 mm) connected to a plastic catheter and to a three-way stopclock was filled with saline solution containing 20% fluorescent dextrans (FITC; molecular weight 70,000; Sigma, St. Louis, MO). The blunted cannula tip was tangentially inserted into the pleural space while saline was flushed over the insertion point to prevent air entrance into the pleural space, and the cannula was then gently advanced along the lung surface. Subsequently, 0.5 ml of the fluorescent solution was injected intrapleurally, the cannula was withdrawn, and the animal was turned to right lateral decubitus position.

Two hours after FITC injection, the animal was turned back to supine position. The internal intercostal muscle fibers of the parasternal region in the third to seventh right intercostal spaces were carefully removed to expose the lymphatic vessels containing the fluorescent dye and were thus clearly detectable though a stereomicroscope (magnification x60–100; Zeiss SV 11) when illuminated with a fluorescent mercury lamp (light wavelength 425/65 nm, HBO 50 W; Zeiss) as in the example of Fig. 1. The microscope image was captured with a digital video camera (Axiocam; Zeiss), processed with a dedicated board, and displayed on a color monitor with a maximal magnification on the video screen of x200. Digital images on the screen were stored and successively automatically analyzed for vessel dimensions with the use of image analysis software (KS300; Zeiss). The diameter of the visualized and micropunctured lymph vessels computed on the stereomicroscopic images ranged between ~50 and ~300 µm.



View larger version (74K):
[in this window]
[in a new window]
 
Fig. 1. A: stereomicroscopic image (magnification x40) of the ventral VII intercostal space (ICS) prepared for micropuncture in a supine, spontaneously breathing, anesthetized rat. A lateral portion of the ICS has been cleared of the external and internal intercostal muscles, leaving intact the thin layer consisting of the parietal pleura and the subpleural tissue through which the lung surface covered by a layer of green fluorescent FITC dextrans injected intrapleurally are clearly visible. The dark blood vessels supplying the pleural tissues and running almost perpendicular to the rib are clearly evident against the green intrapleural background. At right, a long intercostal lymph vessel is evident running along the cranial rim of the caudal rib (dotted line). B: image reconstruction obtained through imaging software to highlight the profile of the lymphatic vessel shown in A. This procedure allows us to abolish the artifact reflexes, such as that on the left bottom edge of the lymphatic vessel caused by the optical fiber illumination on the uneven surface of the intercostal space.

 
The arrangement of the intercostal lymphatics exposed and micropunctured in the present study was very variable. Some vessels were located either in the paravertebral loose interstitial tissue or in the endothoracic fascia of the intercostal space, running parallel to the longitudinal axis of the sternum; others followed instead the cranial curvature of the ribs, describing an angle of 60–90° with respect to the sternum axis. Most vessels were located deeply in the subpleural layer that is very thin and strictly connected to the parietal mesothelium. Therefore, the surgical approach required a careful removal of both the external and the internal intercostal muscles down to the endothoracic fascia. Given the size of the rat intercostal spaces, such a preparation could usually be satisfactorily performed only in the third to seventh intercostal spaces, whose ventral width is larger compared with the other spaces in supine rats. Hence, Plymph and Pint were recorded only in the ventral portion of supine animals at the same or slightly higher level of the right atrium.

Recording of intraluminal lymphatic and interstitial hydraulic pressure. The hydraulic pressures within the visualized lymphatic vessel lumen (Plymph) and in the adjacent intercostal interstitial space (Pint) were measured by means of the micropuncture technique while the animal was spontaneously breathing though the intratracheal cannula. Pressure recordings were performed using glass micropipettes, with a taper of ~150 µm beveled down to a tip diameter of 2–4 µm and filled with 1 M NaCl solution, that were inserted in a pipette holder filled with the same solution. The holder was connected to a mineral oil-filled pressure transducer (Gould Instruments System) motor driven by an electrohydraulic system (Dual Servonull pressure measuring system; Vista Electronics, Ramona, CA). The amplified pressure signal was conveyed and displayed on the monitor screen utilizing the same equipment described for the vascular pressure recordings. Before its use, each micropipette was calibrated in a modified Lucite box by imposing step changes of ±5 mmHg in the box chamber; pipettes displaying a nonlinear calibration in the pressure range ±30 mmHg were discarded. After calibration, pipette holders were mounted in two three-dimensional hydraulic micromanipulators (Joystick Micromanipulator MO-188 or MO-109; Narishighe, Tokyo, Japan) equipped with a fourth micromanipulator movement to drive the tip of the micropipette into the tissue. Electrical zeroing of the recording system was performed before and immediately after each measurement by dipping the micropipette tip in a saline pool positioned at the same height of the pipette insertion point. Criteria for acceptance of the micropipette pressure recordings were 1) an unchanged electrical zero of the system upon withdrawal from the tissue compared with preinsertion value, 2) a stable pressure reading for at least 2 min, and 3) repeated measurements from the same area within 1 mmHg of each other.

In the same animal, up to four paired Plymph and Pint recordings were obtained. After the pipette tip was positioned into the chosen lymph vessel, another pipette was inserted in the adjacent interstitium ~10 µm from the outer lymphatic vessel surface. The microsurgical procedure to expose the lymphatics deep in the parasternal intercostal spaces required 30–60 min; hence, measurements of Plymph and Pint began at ~150–180 min after dextran injection and 180–210 min after anesthesia induction. On average, experiments lasted up to 6 h, during which the animals were always spontaneously breathing.

In a small group (n = 3), after pressure recording during spontaneous breathing, rats were paralyzed with a single intravenous dose of pancuronium bromide (~8 mg/kg) and then passively ventilated (ventilator model 7025; Ugo Basile, Comerio, Italy) with room air, maintaining the same respiratory frequency and tidal volume observed in the previous phase of spontaneous ventilation. Alveolar pressure ranged from atmospheric, at end expiration, to ~18 mmHg at end inspiration for a tidal volume of ~6 ml (~20 ml/kg). A small bolus of anesthetic cocktail was given before paralysis; subsequently, the adequate level of anesthesia was assessed to maintain a stable arterial pressure. Plymph and adjacent Pint were then recorded from the same intercostal vessels where they had been previously recorded during spontaneous ventilation. In most cases, no indication of vessel damage from the previous micropuncture was detectable. However, in a few instances, the first pipette insertion caused a leak in the lymph vessel wall, as indicated by a fluorescent spot in the tissue around the vessel; in this case, the injured area was avoided and micropuncture was performed in a new site in an intact segment of the same vessel. At the end of the experiment the animals were euthanized with an anesthesia overdose.

Data analysis. Data are reported as means ± SE. Absolute values were compared using one-way ANOVA. Differences between mean values were considered significant at P < 0.05. Whenever one-way ANOVA detected a significant difference between mean values, all pairwise multiple comparison procedures were performed (Bonferroni t-test).

The correlation existing between the end-inspiratory ({Delta}Ptm-I) and the corresponding end-expiratory ({Delta}Ptm-E) transmural pressure gradient was assessed by performing the Pearson product moment correlation with significance for P > 0.05.

To appreciate the relative importance of cardiogenic and respiratory swings in determining the overall shape of the Plymph and Pint traces, we performed a frequency-domain analysis of the time-domain pressure traces by means of fast Fourier transformation (FFT). Reference frequencies for cardiac and respiratory activity have been obtained from arterial and tidal volume time-domain traces, respectively. FFT of {Delta}Ptm was performed with Origin software (version 5.0; Microcal Software, Northampton, MA) by segmenting the most stable recordings obtained into blocks of 1,024 samples (10.24 s of recording) and performing a baseline correction for each block to minimize artifactual direct current components.

Stereomicroscopic images were enhanced using Simple PCI software (Compix, Cranberry Township, PA).


    RESULTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
Spontaneous ventilation. During the whole experiment, the anesthetized rats spontaneously breathed at a tidal volume of 4 ± 0.34 ml and a respiratory rate of 66 ± 2.9 cycles/min. Heart rate and mean arterial and venous pressures averaged 284.7 ± 9.5 cycles/min, 90.6 ± 4.2 mmHg, and 8.8 ± 1.3 mmHg, respectively. During the end-expiratory phase, at a chest wall volume corresponding to the functional residual capacity, esophageal pressure (Pesoph) was –1.5 ± 0.7 mmHg and decreased to –4.4 ± 0.8 mmHg at attainment of the end-inspiratory volume. The respiratory and the cardiovascular parameters remained essentially steady throughout the whole experimental period, slowly declining only after ~6 h of deep general anesthesia.

In Fig. 2A, typical recordings of Plymph (middle, continuous line) and Pint (middle, dotted line) obtained during spontaneous breathing at 93 cycles /min (~1.6 Hz) are presented. The Plymph and Pint traces are characterized by large pressure waves associated with the changes in tidal volume (top) during spontaneous respiratory swings. Small cardiogenic oscillations, associated with cardiac activity and amounting to ~0.5 mmHg, also are detectable in the original Plymph trace. In the example in Fig. 2A, the end-expiratory (Plymph-E) and end-inspiratory (Plymph-I) intraluminal lymphatic pressure averaged –0.7 ± 0.2 and –3 ± 0.1 mmHg, respectively, whereas the end-expiratory (Pint-E) and end-inspiratory (Pint-I) intercostal interstitial pressures were 4 ± 0.5 and –2.8 ± 0.4 mmHg, respectively. Each of the above pressure values was obtained by averaging the corresponding pressure peaks in a time frame of up to 10 s.



View larger version (20K):
[in this window]
[in a new window]
 
Fig. 2. A: simultaneous recording of respiratory tidal volume (top) and intralymphatic (Plymph; middle, solid line), and interstitial (Pint; middle, dotted line) pressures obtained during spontaneous breathing at 93 cycles/min. The net transmural pressure gradient ({Delta}Ptm) calculated as {Delta}Ptm = Plymph – Pint is shown (bottom). Note that although both Plymph and Pint decrease upon inspiration, the onset of pressure drop as well as the entity of Plymph and Pint pressure change varies from breath to breath. In this site, the cardiogenic oscillations amounted to ~1.5 mmHg and are detectable only in the Plymph reading. The observed delay (~100 ms) between the inspiratory Plymph and Pint change and the onset of volume signal is likely related to the delay between the onset of inspiratory muscle contraction and the volume signal integrated from the actual flow recorded by the pneumotachograph. B: simultaneous recording of tidal volume, Plymph, Pint, and {Delta}Ptm during mechanical ventilation in paralyzed rats at a breathing frequency of 60 cycles/min (1 Hz). Note that at variance with spontaneous ventilation, both Plymph and Pint increase during passive lung inflation. Cardiogenic oscillations are detectable on the Pint trace.

 
When the data obtained from all readings were averaged, Plymph-E was –2.5 ± 1 mmHg (range: from –18.4 to 13.7 mmHg; n = 47) and was significantly lower (P < 0.01, one-way ANOVA) than the corresponding average Pint-E amounting to 3 ± 0.7 mmHg (range: from –9.9 to 10.7 mmHg; n = 42). The corresponding average Plymph-I and Pint-I values were –21.1 ± 1.3 mmHg (range: from –28 to –5.6 mmHg; n = 47) and –12.2 ± 1.3 mmHg (range: from –3 to 3.8 mmHg; n = 42), respectively. Therefore, the inspiratory maneuver caused both Plymph and Pint to drop significantly (P < 0.001, one-way ANOVA) by 18.6 ± 1.8 and 15.3 ± 1.4 mmHg, respectively, compared with the corresponding end-expiratory values. Figure 2 clearly shows how {Delta}Ptm (bottom; {Delta}Ptm = Plymph – Pint) is not constant from breath to breath but actually changes over time, shifting from –5.3 ± 0.5 mmHg at end expiration to 0.5 ± 0.3 mmHg at end inspiration.

In the attempt to verify whether two functionally different populations of lymphatic vessels could be distinguished on the basis of their absorptive (negative {Delta}Ptm) or propulsive (positive {Delta}Ptm) roles throughout the respiratory cycle, the end-inspiratory transmural pressure gradients ({Delta}Ptm-I) were plotted as a function of the corresponding end-expiratory ({Delta}Ptm-E) values, as shown in Fig. 3. Data points located in the quadrant 1 of Fig. 3 (n = 23, 57.5% of total data points) identify sites at which lymph may be formed during the entire respiratory cycle. Vice versa, data points in quadrant 3 (n = 6, 15% of total data points) correspond to lymphatic sites where {Delta}Ptm favors propulsion only. However, 12.5% of the data points fell in quadrant 2 (n = 5), identifying vessels in which {Delta}Ptm was negative during the end-expiratory pause and positive at end inspiration, whereas in another 15% of the vessels, {Delta}Ptm was negative upon inspiration and positive during the end-expiratory phase (quadrant 4, n = 6). As a result of the dispersion of data points in the four quadrants, no significant linear regression ({Delta}Ptm-I = –5.9 + 0.3{Delta}Ptm-E; r2 = 0.05; n = 40) or correlation (correlation coefficient = 0.23; P = 0.15; n = 40) was found between the two variables. Hence, data suggest that a single lymphatic vessel may actually play an absorptive and/or a propulsive role, depending on the tissue stress acting on its wall during the respiratory cycle. Despite the great functional heterogeneity shown by data in Fig. 3, the {Delta}Ptm averaged over the entire respiratory cycle was –7.6 ± 1.7 mmHg (n = 40) at the end-expiratory lung volume ({Delta}Ptm-E) and did not significantly change at end inspiration ({Delta}Ptm-I = –6. ± 1.4 mmHg).



View larger version (14K):
[in this window]
[in a new window]
 
Fig. 3. End-inspiratory transmural pressure gradients ({Delta}Ptm-I) are plotted as a function of the corresponding end-expiratory transmural pressure gradients ({Delta}Ptm-E) in spontaneous ventilation. Negative {Delta}Ptm values indicate the existence of a net hydraulic pressure gradient from the interstitium to the lymphatic lumen. Vice versa, positive {Delta}Ptm values may support either retrograde fluid flux and/or lymph propulsion. According to the position of data points in the plot quadrants, four functional conditions may be recognized. In cases of data falling in quadrants 1 and 3, {Delta}Ptm is negative or positive, respectively, during the whole respiratory cycle. In cases of data in quadrants 2 and 4, {Delta}Ptm may instead be either negative during expiration and positive during inspiration (quadrant 2) or vice versa (quadrant 4). As a result of this wide functional variability, no significant linear regression ({Delta}Ptm-I = –5.9 + 0.3{Delta}Ptm-E; r2 = 0.05; n = 40) or correlation (correlation coefficient = 0.233; P = 0.147; n = 40) was found between the two variables.

 
Mechanical ventilation. In animals (n = 3) that underwent mechanical ventilation after the phase of spontaneous ventilation, the respiratory rate (75 ± 15 cycles/min) and tidal volume (4.6 ± 1.6 ml) were set equal to the corresponding values under spontaneous breathing. During mechanical ventilation, alveolar pressure was set equal to zero at end expiration and increased up to ~15 mmHg at end inspiration. Arterial and venous pressures averaged 95 ± 8.2 and 7.4 ± 2 mmHg, respectively, and were not significantly different from values previously observed during spontaneous breathing. During mechanical ventilation, Pesoph averaged –1.6 ± 0.7 mmHg at end expiration and increased to 2.8 ± 0.8 mmHg at end inspiration.

An example of the Plymph and Pint traces during mechanical ventilation at positive alveolar pressure in paralyzed respiratory muscles is proposed in Fig. 2B. At variance with what was observed during spontaneous ventilation (Fig. 2A), Plymph and Pint both increased with increasing lung volume. In fact, on average, at end expiration with zero alveolar pressure, Plymph-E and corresponding Pint-E averaged –3.1 ± 1.2 (n = 7) and 2.6 ± 2.3 mmHg 8 (n = 7), respectively, and were not significantly different compared with the values attained during spontaneous breathing. However, at the end-inspiratory peak attained with positive alveolar pressure, Plymph-I and Pint-I significantly increased to 28.1 ± 7.8 (P < 0.001) and 28.2 ± 6.3 mmHg (P < 0.001), respectively, with an inspiratory tidal pressure change of 31.3 ± 8.5 and 25.6 ± 5.6 mmHg, respectively.

From the FFT analysis of the pressure signals (Fig. 4B), one may appreciate that although the major source of Plymph and Pint oscillations during mechanical ventilation is the respiratory component, this is not true for the {Delta}Ptm, whose value at the ventilatory frequency (1 Hz) does not substantially differ from that of other components, including the cardiogenic one (~3 Hz). In addition, at variance with what was observed during spontaneous breathing (Fig. 4A), when the inspiratory {Delta}Ptm peak was much higher than the corresponding Plymph and Pint peaks, with mechanical ventilation the {Delta}Ptm component was significantly reduced during inspiration.



View larger version (19K):
[in this window]
[in a new window]
 
Fig. 4. A: fast Fourier transforms (FFT) of tidal volume (Vt), Plymph, Pint, and {Delta}Ptm traces shown in Fig. 2A during spontaneous breathing. Note that the major frequency component of {Delta}Ptm is represented by the respiratory swings at 1.6 Hz, with a much smaller component at ~3.2 Hz. The peak observed at ~0.3 Hz is artifactual and due to the slow drift observed in the Pint recording (see Fig. 2A). B: FFT of Vt, Plymph, Pint, and {Delta}Ptm traces shown in Fig. 2B during mechanical ventilation. Note that although the respiratory swings account for the most important frequency component of the Plymph and Pint traces, the same is not true for {Delta}Ptm.

 
On average, the net transmural hydraulic pressure gradient was –5.7 ± 2.6 mmHg at end expiration ({Delta}Ptm-E) and –0.1 ± 5.9 mmHg at end inspiration ({Delta}Ptm-I). Over the entire respiratory cycle, {Delta}Ptm was –1.1 ± 1.7 mmHg, not significantly different from zero and significantly lower (P = 0.005, one-way ANOVA) than the value observed in spontaneously breathing animals ({Delta}Ptm = –6.8 ± 1.2 mmHg).

Cardiogenic oscillations. The amplitude of the cardiogenic oscillations was very variable and determined, on average, a tidal increase of Plymph-E and Pint-E of 5.5 ± 2 (n = 21) and 5.1 ± 0.7 mmHg (n = 21), respectively. Such cardiogenic Plymph and Pint swings generated a {Delta}Ptm amounting to –3.7 ± 1.61 mmHg, a value not significantly different from that observed across the wall of lymphatic vessels running on the pleural surface of the muscular part of the paralyzed rat diaphragm (14, 18). When performing a FFT analysis of a time frame of typical Plymph, Pint, and {Delta}Ptm traces, it is possible to distinguish the prevalent component of pressure oscillation. For instance, Fig. 4A presents such an analysis performed on traces in Fig. 2A; one may appreciate that the respiratory component, at ~1.5 Hz, is the most relevant source of Plymph and Pint pressure oscillation and, more significantly, of {Delta}Ptm, whereas the cardiogenic component (at ~3.2 Hz in this example) is distinguishable only in the Plymph recording. Note that the significant peak observed in Fig. 4A at ~0.3 Hz is artifactual and is due to the slow drift observed in the Pint trace and thus calculated {Delta}Ptm values (see Fig. 2A). Cardiogenic oscillations amounting to ~2 mmHg also are visible in the Pint and {Delta}Ptm traces in Fig. 2B, corresponding to the oscillation component at ~3 Hz in Fig. 4B.


    DISCUSSION
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The lymphatic vessels investigated in the present study belong to the pleural lymphatic network, which provides fluid and solute drainage from the pleural cavity, the subpleural interstitial space, and the intercostal muscles. These vessels are subject to cyclic displacements, related to the change in chest shape and volume during the respiratory activity. In such an experimental condition, the reliability of the methodology and the approach used for pressure measurements becomes crucial.

Methodological evaluation. The micropuncture technique used in the present study offers the great advantage of allowing measurements of hydraulic pressure in tissues and in microvessels that would not be otherwise accessible. However, pressure measurement might be affected by artifacts caused by possible distortion of the flexible pipette tip and change in recording site within the moving tissue. To avoid tissue distortion during insertion, the pipette was driven into the tissue and/or the lymphatic vessel at an angle of ~30° with respect to the tissue/vessel surface. This approach had been proven to be the least invasive during pipette insertion in steady intercostal interstitium (7). The similarity between present Plymph-E values and those obtained in paralyzed rabbits (14) and between present Pint-E values and those recorded in spontaneously breathing rats using saline-filled catheters (16) provides an indirect validation of this micropipette insertion approach in relatively still tissues.

Judging from the stereomicroscope images during recording, inspiratory chest expansion caused an outward and cranial displacement of the tissues of the order of 200–300 µm. In some instances, the deformation of the pipette tip against the vessel wall or the tissue fibers caused saturation of the pressure signal, leading to rejection of the reading. However, when the pipette was inserted along the major axis of the lymph vessel, or parallel to it in the interstitium, distortion was minimized and a stable and reproducible recording was obtained over several minutes. This insertion technique also allowed us to clearly distinguish whether the tip was in the vessel or in the adjacent interstitium. In any case, the completely opposite response observed in Plymph and Pint for similar tidal volume changes attained with active inspiration or passive lung inflation (Fig. 2, A and B) suggests that possible artifacts caused by the recording device might only marginally affect the actual values.

Plymph, Pint, and {Delta}Ptm during the respiratory cycle in spontaneous and mechanical ventilation. As observed in previous studies carried out using the same technique on paralyzed rabbits and rats, both the diaphragmatic (18) and the intercostal (14) lymphatic vessels of sizes ranging from 50 to 300 µm may be functionally regarded as initial lymphatics (22). In fact, the pressure oscillations caused by spontaneous contraction of the lymphatic smooth muscle cells, commonly observed in organs such as the mammalian mesentery or the bat wing (1, 22), were only very rarely encountered in the present and in our previous studies (14, 18). Hence, from this standpoint, pleural lymphatics seem to functionally behave like the lymphatics network supplying other tissues that undergo high tissue stresses, such as the skeletal muscle (23, 24) and the myocardium (5).

Pint-E depends on the local stress exerted between the solid macromolecular elements in the tissue as well as on the water content of the tissue (1) as indicated by the progressive increase of Pint with overhydration (9). Because intercostal microvasculature provides net fluid filtration into the tissue (15), the absorptive gradient required to maintain the interstitial fluid homeostasis, as well as the negative end-expiration Pint value, is therefore set by the lymphatic drainage, which indeed provides absorptive {Delta}Ptm (Fig. 3, quadrants 1 and 4) in most vessels at end expiration.

Upon inspiration, variable mechanical stresses arise in the intercostal tissues, resulting from the simultaneous contribution of multiple mechanical factors: 1) the inspiratory contraction of the external intercostal muscles that run ventrally in the craniocaudal direction and likely exert uneven tangential stresses on the differently oriented parasternal or paracostal subpleural interstitial fibers; the contribution of the external intercostal muscles to lung inflation varies markedly in the rostrocaudal direction, with the inspiratory rib displacement much more relevant in the rostral interspaces compared with the caudal ones (2, 3); and 2) the inspiratory decrease in pleural liquid pressure (Pliq), which exerts a further inward pull, acting perpendicularly to the pleural surface. Such a local mechanical complexity results in an increased local tensile stress, as suggested by the decrease in Plymph and Pint observed during spontaneous inspiration. The similarity between Pint and Plymph inspiratory swings suggests that the stress arising in the tissue during inspiration was entirely transmitted to the lymphatic vessel lumen through the solid matrix components. Indeed, the initial lymphatics are delimited by a highly compliant endothelial wall (22), which is not expected to modify the stress exerted by the tissue fibers to the lymphatic lumen via the anchoring filaments. The variable delay observed between Pint and Plymph changes at the spontaneous inspiratory onset (Fig. 2A) is likely related to the viscoelastic properties of the matrix fibers though which mechanical transmission of tissue stress to the outer lymphatic wall takes place. Such a delay, usually not present in mechanical ventilation in paralyzed rats (Fig. 2B), may reflect both changes in tissue compliance during intercostal muscle contraction or relaxation and/or alternate muscle recruitment.

During spontaneous breathing, tissue stress magnitude seems to be more effective than respiratory frequency in determining {Delta}Ptm changes. Indeed, although the {Delta}Ptm developing during cardiogenic oscillations may support lymph function in the paralyzed diaphragm (18), the amplitude of {Delta}Ptm induced by respiratory activity is much prevailing (Fig. 4).

From a fluid dynamics standpoint, a negative {Delta}Ptm value across the lymphatic wall potentially drives an interstitial to lymphatic fluid flow, thus promoting lymph formation. It is worth noting that the initial lymphatic vessel may be compared, from the mechanical standpoint, to a nonelastic collapsible vessel (4); therefore, the tensile stress exerted by the tissue fibers on the outer surface prevents vessel collapse despite the occurrence of a negative transmural pressure. In the majority (~70%) of the recordings (Fig. 3, quadrants 1 and 2) {Delta}Ptm was in favor of lymph formation during the end-expiratory phase. Provided that lymph pressure waves caused by the intrinsic spontaneous contraction of the smooth muscles cells were not observed in the present study, the setting and maintenance of the end-expiratory {Delta}Ptm likely depend on cardiogenic oscillations, similar to those observed in the lymphatic diaphragmatic network of paralyzed rats (18). In intercostal tissues, the cardiogenic swings depend on 1) displacement of lung parenchyma and pleural liquid during cardiac motion and 2) mechanical transmission of arterial pressure waves along the elastic walls of the internal mammarian and intercostal arteries.

Whereas ~60% of the lymphatic vessels contributed to lymph formation during the entire respiratory cycle (Fig. 3, quadrant 1), in ~40% of the vessels a positive {Delta}Ptm developed, at least transiently, suggesting the occurrence of either forward fluid propulsion and/or backflow toward the interstitial space. The actual direction of the fluid flux between the interstitium and the lymphatic lumen cannot be detected with the techniques used in the present study, and thus we cannot exclude the existence of lymphatic to interstitial fluid backflow. However, unidirectional flaplike valves located in the lymphatic vessel wall (primary valves) have been recently described in the lymphatics supplying the skeletal muscles (6, 24) and the diaphragm (17). Given that these valves seem to hinder fluid backflow, a positive {Delta}Ptm might reasonably be interpreted in terms of lymph propulsion between adjacent lymphangions rather than as an index of retrograde fluid flux.

In paralyzed rats mechanically ventilated at zero end-expiratory alveolar pressure, Pint-E, Plymph-E, and {Delta}Ptm-E did not significantly differ compared with their values during spontaneous breathing, suggesting that end-expiratory muscle tone did not significantly affect, per se, the lymphatic function, which was guaranteed by the unaffected cardiogenic oscillations. However, at variance with spontaneous breathing, Pint-I and Plymph-I both increased with passive lung inflation as a result of compressive tissue stress due to increased alveolar pressure. In this condition, the average {Delta}Ptm-I was essentially nullified. This finding indicates that tissue stress induced by the intercostal muscle contraction and not the change in chest wall volume is required to support lymphatic function, which in this condition may only rely on the unaffected but less efficient cardiogenic oscillations (Fig. 4B).

Pleural fluid drainage. In spontaneously breathing rats at approximately heart level, costal Pliq averages approximately –2 mmHg at end expiration and approximately –3 mmHg at end inspiration, respectively (11, 16). Assuming that the present Plymph values reflect Plymph within the stomata (19) facing the pleural space, a net pressure gradient varying between approximately –0.5 mmHg at end expiration and approximately –18 mmHg at end inspiration, respectively, would develop between the pleural fluid and the stomata lumen. Therefore, during spontaneous breathing, lymph formation might occur through the whole respiratory cycle, and in particular upon inspiration. Pleural fluid drainage would instead be hindered during mechanical ventilation when Plymph becomes positive.

In summary, the analysis of {Delta}Ptm development during either the respiratory or cardiac cycle shows that the active contraction of inspiratory muscles and not the chest wall volume change is required to enhance lymph formation and progression in the thoracic lymphatics. The three-dimensional architecture of matrix macromolecules, their arrangement in the intercostal spaces, and their mechanical properties seem to play a fundamental role in determining and modulating lymph formation and propulsion in these initial lymphatics under spontaneous breathing. Given the importance of the lymphatic system in controlling fluid homeostasis in the thoracic tissues and in particular in the pleural cavity, mechanical ventilation per se is therefore expected to determine an increase of thoracic tissues hydration and pleural effusion. A similar situation may well occur in the lung parenchyma, motivating the latent subedematous condition often observed in lungs of patients exposed to positive pressure ventilatory regimes.


    GRANTS
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
This research was funded by the Italian Ministry of the University and of Scientific and Technological Research (FAR 2003; FIRB 2001, contract RBAU01L4MZ) and by a contribution for Research of the University of Insubria.


    FOOTNOTES
 

Address for reprint requests and other correspondence: D. Negrini, Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Università degli Studi dell'Insubria, Via J.H. Dunant 5, 21100 Varese, Italy (E-mail: daniela.negrini{at}uninsubria.it)

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 

  1. Aukland K and Reed R. Interstitial-lymphatic mechanisms in the control of extracellular fluid volume. Physiol Rev 73: 1–78, 1993.
  2. De Troyer A, Legrand A, and Wilson T. Respiratory mechanical advantage of the canine external and internal intercostal muscles. J Physiol 518: 283–289, 1999.
  3. De Troyer A and Wilson T. Coupling between the ribs and the lung in dogs. J Physiol 540: 231–236, 2002.
  4. Fung YC. Biomechanics. Motion, Flow, Stress, and Growth. New York: Springer, 1990.
  5. Mehlhorn U, Davis KL, Burke EJ, Adams D, Laine GA, and Allen SJ. Impact of cardiopulmonary bypass and cardioplegic arrest on myocardial lymphatic function. Am J Physiol Heart Circ Physiol 268: H178–H183, 1995.
  6. Mendoza E and Schmid-Schönbein G. A model for mechanism of primary lymphatic valves. J Biomech Eng 125: 407–414, 2003.
  7. Miserocchi G, Kelly S, and Negrini D. Pleural and extrapleural interstitial liquid pressure measures by cannulas and micropipettes. J Appl Physiol 65: 555–562, 1988.
  8. Miserocchi G, Mariani E, and Negrini D. Role of the diaphragm in setting liquid pressure in serous cavities. Respir Physiol 50: 381–392, 1982.
  9. Miserocchi G, Negrini D, Del Fabbro M, and Venturoli D. Pulmonary interstitial pressure in intact in situ lung: the transition to interstitial edema. J Appl Physiol 74: 1171–1177, 1993.
  10. Miserocchi G, Negrini D, and Gonano C. Direct measurements of interstitial pulmonary pressure in in-situ lung with intact pleural space. J Appl Physiol 69: 2168–2174, 1990.
  11. Miserocchi G, Negrini D, and Mortola J. Comparative features of Starling-lymphatic interaction at the pleural level in mammals. J Appl Physiol 56: 1151–1156, 1984.
  12. Miserocchi G, Venturoli D, Negrini D, and Del Fabbro M. Model of pleural fluid turnover. J Appl Physiol 75: 1798–1806, 1993.
  13. Negrini D, Ballard S, and Benoit J. Contribution of lymphatic myogenic activity and respiratory movements to pleural lymph flow. J Appl Physiol 76: 2267–2274, 1994.
  14. Negrini D and Del Fabbro M. Subatmospheric pressure in the rabbit pleural lymphatic network. J Physiol 520: 761–769, 1999.
  15. Negrini D, Del Fabbro M, and Venturoli D. Fluid exchanges across the parietal peritoneal and pleural mesothelia. J Appl Physiol 74: 1779–1784, 1993.
  16. Negrini D and Miserocchi G. Size related differences in parietal extrapleural and pleural liquid pressure distribution. J Appl Physiol 67: 1967–1972, 1989.
  17. Negrini D, Moriondo A, and Mukenge S. Intercostal lymphatic pressure in spontaneously breathing rats (Abstract). FASEB J 18: 440.1, 2004.
  18. Negrini D, Moriondo A, and Mukenge S. Transmural pressure during cardiogenic pressure oscillations in rodent diaphragmatic lymphatic vessels. Lymphat Res Biol 2: 69–81, 2004.
  19. Negrini D, Mukenge S, Del Fabbro M, Gonano C, and Miserocchi G. Distribution of diaphragmatic lymphatic stomata. J Appl Physiol 70: 1544–1549, 1991.
  20. Negrini D, Passi A, De Luca G, and Miserocchi G. Pulmonary interstitial pressure and proteoglycans during development of pulmonary edema. Am J Physiol Heart Circ Physiol 270: H2000–H2007, 1996.
  21. Negrini D, Tenstad O, and Wiig H. Interstitial exclusion of albumin in rabbit lung during development of pulmonary oedema. J Physiol 548: 907–917, 2003.
  22. Schmid-Schönbein G. Microlymphatics and lymph flow. Physiol Rev 70: 987–1019, 1990.
  23. Skalak T, Schmid-Schönbein G, and Zweifach B. New morphological evidence for a mechanism of lymph formation in skeletal muscle. Microvasc Res 28: 95–112, 1984.
  24. Trzewik J, Mallipatty S, Artmann G, Delano F, and Schmid-Schönbein G. Evidence for a second valve system in lymphatic endothelial microvalves. FASEB J 15: 1711–1717, 2001.



This article has been cited by other articles:


Home page
Br J AnaesthHome page
N. Soni and P. Williams
Positive pressure ventilation: what is the real cost?
Br. J. Anaesth., October 1, 2008; 101(4): 446 - 457.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. Moriondo, F. Bianchin, C. Marcozzi, and D. Negrini
Kinetics of fluid flux in the rat diaphragmatic submesothelial lymphatic lacunae
Am J Physiol Heart Circ Physiol, September 1, 2008; 295(3): H1182 - H1190.
[Abstract] [Full Text] [PDF]


Home page
J. Physiol.Home page
A. Moriondo, A. Grimaldi, L. Sciacca, M. L. Guidali, C. Marcozzi, and D. Negrini
Regional recruitment of rat diaphragmatic lymphatics in response to increased pleural or peritoneal fluid load
J. Physiol., March 15, 2007; 579(3): 835 - 847.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
289/1/H263    most recent
00060.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (6)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moriondo, A.
Right arrow Articles by Negrini, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moriondo, A.
Right arrow Articles by Negrini, D.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2005 by the American Physiological Society.