Am J Physiol Heart Circ Physiol 289: H2468-H2477, 2005. First published August 5, 2005; doi:10.1152/ajpheart.00570.2005
0363-6135/05 $8.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
289/6/H2468    most recent
00570.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wiley, J. J.
Right arrow Articles by Pollard, A. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wiley, J. J.
Right arrow Articles by Pollard, A. E.

Measuring surface potential components necessary for transmembrane current computation using microfabricated arrays

J. James Wiley,1 Raymond E. Ideker,2 William M. Smith,1 and Andrew E. Pollard1

1Department of Biomedical Engineering, Cardiac Rhythm Management Laboratory and 2Departments of Medicine, Physiology, and Biophysics, Cardiac Rhythm Management Laboratory, University of Alabama at Birmingham, Birmingham, Alabama

Submitted 31 May 2005 ; accepted in final form 2 August 2005


    ABSTRACT
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
This study was designed to test the feasibility of using microfabricated electrodes to record surface potentials with sufficiently fine spatial resolution to measure the potential gradients necessary for improved computation of transmembrane current density. To assess that feasibility, we recorded unipolar electrograms from perfused rabbit right ventricular free wall epicardium (n = 6) using electrode arrays that included 25-µm sensors fabricated onto a flexible substrate with 75-µm interelectrode spacing. Electrode spacing was therefore on the size scale of an individual myocyte. Signal conditioning adjacent to the sensors to control lead noise was achieved by routing traces from the electrodes to the back side of the substrate where buffer amplifiers were located. For comparison, recordings were also made using arrays built from chloridized silver wire electrodes of either 50-µm (fine wire) or 250-µm (coarse wire) diameters. Electrode separations were necessarily wider than with microfabricated arrays. Comparable signal-to-noise ratios (SNRs) of 21.2 ± 2.2, 32.5 ± 4.1, and 22.9 ± 0.7 for electrograms recorded using microfabricated sensors (n = 78), fine wires (n = 78), and coarse wires (n = 78), respectively, were found. High SNRs were maintained in bipolar electrograms assembled using spatial combinations of the unipolar electrograms necessary for the potential gradient measurements and in second-difference electrograms assembled using spatial combinations of the bipolar electrograms necessary for surface Laplacian (SL) measurements. Simulations incorporating a bidomain representation of tissue structure and a two-dimensional network of guinea pig myocytes prescribed following the Luo and Rudy dynamic membrane equations were completed using 12.5-µm spatial resolution to assess contributions of electrode spacing to the potential gradient and SL measurements. In those simulations, increases in electrode separation from 12.5 to 75.0, 237.5, and 875.0 µm, which were separations comparable to the finest available with our microfabricated, fine wire, and coarse wire arrays, led to 10%, 42%, and 81% reductions in maximum potential gradients and 33%, 76%, and 96% reductions in peak-to-peak SLs. Maintenance of comparable SNRs for source electrograms was therefore important because microfabrication provides a highly attractive methods to achieve spatial resolutions necessary for improved computation of transmembrane current density.

microimpedance; action potential propagation; Laplacian electrograms; signal conditioning; bidomain modeling


THE TRANSMEMBRANE CURRENT density (Im) in heart tissue depends on the balance between active sarcolemmal ionic currents and the passive current flowing in the intracellular, interstitial, and extracellular volume conductors. Because Im provides a direct measure of electrical source and load influences on adjacent myocytes, its in vivo computation remains an attractive goal in cardiac electrophysiological studies. Significant emphasis has been placed recently on the balance between the active ionic currents and the passive intracellular current flowing through the myoplasm and gap junctions in considering Im (14, 15, 28, 29). However, it is important to recognize that intracellular access is not required for Im computation (26, 32). In fact, Im computation from the epicardium is possible on theoretical grounds provided that 1) a system of electrodes with sufficiently fine spatial resolution is available for surface potential gradient measurements in orthogonal directions, 2) a method to either measure or eliminate the potential gradient between the interstitium and the extracellular volume conductor is available, 3) a method to either measure or eliminate the transmural interstitial potential gradient is available, and 4) three-dimensional interstitial and extracellular impedance data are available to measure directional currents from the potential gradients.

The goal of the present study was to assess the feasibility of using microfabricated sensor arrays for the necessary surface potential recordings to measure surface potential gradients in orthogonal directions. Here we hypothesized advantages of using microfabrication compared with traditional hand-assembled approaches because microfabrication allows finer spatial resolution and more precise localization of individual electrodes. Although mature techniques for neural recordings using microfabricated sensors are available (8, 35), application in cardiac electrophysiological studies has been more limited (7, 12). After considering design steps associated with careful signal conditioning to achieve high-quality unipolar electrograms, we measured surface potential gradients and surface Laplacians (SLs) with microfabricated arrays at comparable signal-to-noise ratios (SNRs) to surface potential gradients and SLs measured using hand-assembled arrays in experiments involving perfused rabbit hearts. Influences of electrode separation on potential gradient and SL measurements were additionally considered in simulations incorporating a bidomain representation of tissue structure and a two-dimensional network of guinea pig myocytes prescribed following the Luo and Rudy dynamic (LRd) membrane equations (9, 10, 17, 23). Collectively, our findings support microfabrication-based strategies for accurate determination of surface potential contributions for improved in vivo computation of Im.


    GENERAL THEORY
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The importance of the surface potential gradient and the SL for improved in vivo epicardial Im computation is apparent from inspection of the governing equation expressed in terms of the interstitial volume conductor (20, 27)

(1)
In Eq. 1, go are specific interstitial bidomain conductivities in the x, y, and z directions and {phi}o is the interstitial potential. Under experimental conditions in which recording electrodes are embedded in an insulating medium that limits current flowing from the interstitium to the extracellular volume conductor and activation sequences are initiated epicardially in close proximity to the electrodes to limit current flowing intramurally within the interstitium, z components to Eq. 1 can be neglected. Furthermore, conditions under which directional differences in go,x and go,y are assumed place the main emphasis on accurate determination of the surface potential gradient terms.

Such spatial differences in surface potentials were used by Witkowski et al. (32), who assumed uniform planar depolarization wavefront expansion within the interrogation region and derived an expression for Im with the temporal derivative of the magnitude for the surface potential gradient as the sole time- and space-dependent term. Combinations of surface potentials were therefore recorded with 5-electrode arrays. Using electrodes separated from one another on a size scale of 2–3 myocytes (210 µm), those investigators estimated Im in canine ventricular epicardium and characterized shape changes in these estimates to index sodium channel activation intervals and the ratio between inward and outward sarcolemmal current during depolarization wavefront expansion. Because their approach assumed constant conduction velocity and homogeneous surface potential gradients, they were able to demonstrate consistency in the shapes for estimated Im between recordings made with 210-µm electrode separation and recordings made over a range from 65- to 420-µm electrode separation. With separations wider than 1 mm, however, estimated Im duration prolonged markedly and the timing for peak inward and outward estimated Im shifted dramatically. More recently, Coronel et al. (3) estimated Im with surface Laplacians (SLs) measured from porcine hearts using 300-µm interelectrode separation. Those investigators found analogous SL shape changes to those described by Witkowski et al. (32) with increases in electrode spacing in their Im estimates.

Although Witkowski et al. (32) suggested cellular level spatial resolution was not required to estimate Im under their assumptions, there are compelling reasons to support finer resolution if all necessary component terms for improved Im computation using Eq. 1 are to be made available. Inhomogeneities in the surface potential gradients diminish with refinement, leading to improved gradient measurements. Action potential propagation at a microscopic size scale is discontinuous (5, 30), suggesting an approach following Coronel et al. (3) is more readily applicable to cardiac tissue than the approach of Witkowski et al. (32), which assumes uniform conduction. Four-electrode impedance measurements with widely spaced electrodes provide effective tissue impedances that are complex combinations of the intracellular, interstitial, and extracellular impedances (21), whereas microimpedances measured with stimulating and recording electrodes separated on a cellular size scale include no intracellular contributions (19). Systems including small, closely spaced recording electrodes for precise potential gradient measurements in orthogonal directions that are bounded by stimulating electrodes to allow interstitial microimpedance measurements in these directions (24) will therefore be required.


    METHODS
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
Heart preparation. Experiments were approved by the Institutional Animal Care and Use Committee. Six New Zealand White rabbits (3–5 kg) were anesthetized with intramuscular ketamine (44 mg/kg) and xylazine (20 mg/kg), followed by intravenous pentobarbital sodium (2.5 ml) and heparin (2.0 ml). Hearts were rapidly excised after a medial sternotomy and retrogradely perfused through the aorta with 3–4 liters of recirculating, oxygenated (95% O2-5% CO2) normal solution containing (in g/l) 7.36 NaCl, 3.96 glucose, 0.2 MgCl2, 2.5 taurine, 0.65 creatine, 0.55 sodium pyruvate, 0.14 NaH2PO4, 3 NaHCO3, and 0.12 CaCl2; pH was 7.3–7.4. Temperature was maintained at 36 ± 1°C. Flow rate was fixed at 45–50 ml/min. Hearts were positioned with the cannula oriented horizontally and the right ventricular (RV) free wall facing up. Before electrophysiological study, excess lung and fat tissue was trimmed from the preparation, although a portion was left attached to the heart so that the indifferent electrode could be placed in this inactive tissue.

Electrode arrays. Hand-assembled and microfabricated arrays were built using a consistent configuration. Schematic diagrams of the arrangements are summarized in Fig. 1. Two line arrays containing seven electrodes with constant interelectrode spacing were oriented perpendicular to one another such that the central point was shared on each line. This allowed surface potentials recorded with a range of interelectrode spacing during individual acquisition intervals to be completed rapidly during experiments. Hand-assembled arrays were built following the method of Witkowski et al. (32). Briefly, that method involved threading silver wires of different diameters through alternate openings in nylon mesh cloth (Small Parts). This controlled wire arrangements, with the alternation minimizing the adjacent electrodes’ influence on the potential measurements, which was identified as an important issue in SL measurements by Witkowski et al. (32). Tensioned wires were epoxied in place, then cut and sanded flush with the epoxy surface to create 13-electrode plaques. Here, the epoxy served as an insulating layer to restrict extracellular current flow away from the epicardium. One such array was built using relatively coarse wires (California Fine Wire, Grover Beach, CA) of 250-µm diameter threaded through mesh with 300-µm openings and thread diameters of 140 µm (Fig. 1A). Center-to-center interelectrode spacing therefore measured 880 µm. Here, electrodes were widely separated compared with myocytes. Another array was built using fine wires of 50-µm diameter threaded through mesh with 74-µm openings and thread diameters of 50 µm to achieve center-to-center interelectrode spacing of 240 µm (Fig. 1B). Individual electrodes in this array were therefore separated more widely than individual myocytes, with separation being on a size scale comparable to that of Witkowski et al. (32) and Coronel et al. (3). Microfabricated arrays were built by Compunetics (Monroeville, PA) who exposed 25-µm silver pads using a laser drill at 50 µm edge-to-edge separation on one side of circuit boards whose traces were routed to interface and amplification circuitry located on the opposite side of the board. Center-to-center interelectrode spacing was 75 µm (Fig. 1C), resulting in electrodes separated on the size scale of individual myocytes. By design, packages were made flexible by using DuPont AP7156 as the base material, Riston Special Fx 900 as the laminate, and DuPont LF7001 as the overlay material. As with the epoxy in the hand-assembled arrays, this material served as an effective insulator. Flexibility was advantageous because it ensured movement of the electrode arrays was coordinated with heart contraction. All arrays were chloridized to lower electrode impedance before electrophysiological study by passing constant current through a concentrated NaCl solution using the electrode to be chloridized as the anode and a strip of silver foil as the cathode. Chloridization followed Malkin and Pendley (18), and we attempted to maintain a 2.0 mA/cm2 current density for 20 min by adjusting the applied current based on electrode surface area.



View larger version (6K):
[in this window]
[in a new window]
 
Fig. 1. Schematic diagrams of the electrode arrangements for the coarse wire (A), fine wire (B), and microfabricated arrays (C). The central electrode (a) in each array was bounded by additional electrodes (b, c, d) emanating in north (N), south (S), east (E), and west (W) directions. All schematics were drawn to scale with a 100-µm calibration bar included in C.

 
Electrode impedance. The impedances of the electrodes were measured with a simple voltage divider circuit. Each electrode was inserted into saline in series with a 1-M{Omega} resistor. A 20-V (peak-peak) sine wave was applied through the resistor and electrode, and the voltage across the electrode was measured (the internal resistance of the waveform generator was only 50 {Omega} and was therefore ignored). The saline bath was common for both the voltmeter and the waveform generator. The impedance (R) of the electrode was then computed by

(2)
with V the voltage across the electrode.

Signal conditioning. Because we recognized a high likelihood for lead noise to complicate data acquisition with the microfabricated arrays based on findings of Hofer et al. (7), considerable emphasis was placed on signal conditioning near the electrodes themselves. Each of the 13 trace leads from the electrodes in the microfabricated arrays was routed to the input of a low-noise instrumentation amplifier (AD623, Analog Devices, Norwood, MA) that was bonded to the circuit side of the flexible board. Each instrumentation amplifier served as a buffer amplifier stage in advance of filtering and acquisition. A comparable arrangement was achieved with the hand-assembled arrays by soldering the lead wires from each array to amplifier inputs on flexible "dummy" boards in which no microfabricated electrodes were included. Lead wire lengths to dummy boards were shorter than 5 cm.

Electrogram measurements. Hearts were stimulated with ventricular pacing from bipolar electrodes applied to RV epicardium located near the recording array in each experiment. Basic drive cycle lengths ranged from 300 to 500 ms, with the cycle length selected to ensure activation sequence initiation from the RV epicardium. Unipolar electrograms were acquired simultaneously and bandpass filtered at 0.05 Hz and 4 kHz cutoff frequencies before sampling at 16,000 samples/s with 14-bit resolution. For acquisition, we used 13 channels from a custom built 528-channel mapping system (34) that allows simultaneous archival of data from 528 channels at a 2,000 samples/s rate or up to 66 channels of data at the 16,000 samples/s rate. Here, the high sampling rate was required to resolve rapid signal characteristics for SLs. In each of the six experiments, 13 unipolar electrograms were recorded with coarse wire, fine wire, and microfabricated arrays under conditions with signal conditioning in close proximity to the electrodes and with signal conditioning distant (~1 m) from the electrodes. This allowed the influence of signal conditioning proximity to be quantified in terms of signal-to-noise ratios (SNRs) measured as peak-to-peak electrogram amplitude divided by root mean square (RMS) noise during diastole. All data from these 6 hearts were used for our analyses. In practice, an array was placed on the epicardium using a micromanipulator, and electrograms were collected with adjacent and distant signal conditioning. Recordings with each array were made over the course of a few minutes. In making the switch from one array to the next, we attempted to maintain the general location, although it was not practical to preserve orientation of the central recording site or of the electrode axes with each switch. A total of 78 SNR values were tabulated from electrograms recorded with and without adjacent signal conditioning for each array type.

Surface potential differences. Surface potential differences were assembled from the unipolar electrograms recorded with adjacent signal conditioning using the electrogram recorded from the central site (a) on each array as the reference using

(3)
with subscript j denoting electrodes in north (N), south (S), east (E), and west (W) directions and subscript k denoting electrodes separated from a at b, c, or d as shown in Fig. 1. With coarse wires, bipolar electrograms were therefore assembled using unipolar electrograms recorded at electrodes spaced 830, 1,710, and 2,590 µm from the central reference, while separations with fine wires were 224, 348, and 720 µm and separations with microfabricated sensors were 75, 150, and 225 µm. A total of 312 bipolar electrograms were then analyzed for each spacing and each electrode type, recognizing the orthogonal orientation for the electrode arrays. Second-difference electrograms were then assembled from component bipolar electrograms using

(4)
such that 78 second-difference electrograms were analyzed for each spacing and each electrode type. SNRs were calculated for all bipolar and second-difference electrograms.

Potential gradients and surface Laplacians. Potential gradients were assembled by scaling each bipolar electrogram by its associated electrode spacing. SLs were assembled by scaling each second-difference electrogram by the square of its associated electrode spacing.

Bidomain simulations. LRd simulations were completed using models of cardiac tissue represented as a bidomain with intracellular and interstitial portions coupled to one another via cell membrane (20, 27). In addition to Eq. 1, electrical activity was therefore described by

(5)
with gi specific intracellular bidomain conductivities in the x and y directions and Vm the transmembrane potential. Domain coupling was then described by

(6)
with {beta} the ratio of membrane surface to element volume [6,350/cm following Giles and Imaizumi (6)], Cm the specific membrane capacitance (1 µF/cm2 as nominal for biological tissue), and Iion the total transmembrane current density resulting from ion channels, pumps, and exchangers as described by the LRd membrane equations. To discretize Eq. 5, we used space steps of {Delta}x = {Delta}y = 12.5 µm. We prescribed values of go,x = 3.17 mS/cm and gi,x = 4.82 mS/cm assuming fibers oriented in the x direction, following the Kléber and Rieger (13) measurements in perfused rabbit papillary muscles after accounting for intracellular (f = 0.8) and interstitial (1 – f = 0.2) volume fractions (22). Values of go,y = 1.17 mS/cm and gi,y = 0.51 mS/cm were then derived from directional conductivity ratios of 2.7 and 9.4, respectively, as reported by Clerc (2). Models measured 5 mm x 5 mm (400 nodes x 400 nodes). Full discretization resulted in sparse linear systems that we solved using the method of conjugate gradients as described in our earlier report (24). Time steps were fixed at {Delta}t = 2 µs to ensure stable and accurate solutions during action potential depolarization.

We assumed the center point of the model was located in the center of a recording array that included 399 total electrodes oriented along fibers and 399 total electrodes oriented across fibers. Bipolar electrograms, second-difference electrograms, potential gradients, and SLs were calculated using the same approach as in the experiments, with the difference that 198 electrograms were available for analysis in each direction moving from the model center point. Action potential propagation was initiated by transmembrane current injection (300 µA/cm2, 2-ms duration) in a 4 x 4 group of nodes at the model edge where electrodes oriented along fibers were located.


    RESULTS
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
Unipolar electrogram recordings. Positioning the buffer amplification stage on the flexible substrate with microfabrication was a significant step in using these arrays for high-quality SL measurements. Adjacent signal conditioning was necessary for the microfabricated sensors because the electrode impedance was considerably larger than the impedances associated with standard wire electrodes. Figure 2 shows electrode impedance as a function of frequency with coarse wires (n = 13; Fig. 2A), fine wires (n = 13; Fig. 2B), and microfabricated sensors (n = 13; Fig. 2C). While impedance increased inversely with electrode diameter as expected and the impedance changes with frequency were consistent between electrode types, suggesting the major factor influencing the overall electrode impedance was the electrode size, it is important to note that the microfabricated sensors had direct-current (DC) impedances 250 times those of the coarse wires. Adjacent signal conditioning compensated for this discrepancy in our measurements as overall SNRs measured with adjacent signal conditioning were 21.2 ± 2.2, 32.5 ± 4.1, and 22.9 ± 0.7 using coarse wires, fine wires, and microfabricated sensors, respectively. Overall SNRs measured with distant signal conditioning were 23.3 ± 3.4, 18.8 ± 4.2, and 13.4 ± 2.2 using coarse wires, fine wires, and microfabricated sensors, respectively. Figure 3 shows the unipolar electrograms with the highest SNRs for each group. Electrograms shown on the left side were recorded with adjacent signal conditioning while those on the right side were recorded with distant signal conditioning. SNRs are marked to the left of each waveform. As a separate index of lead noise, each electrogram was differentiated in time since that process is known to amplify lead noise in practice. With the use of coarse wires (Fig. 3A), the largest measured SNRs were comparable at 41.6 and 49.7, with adjacent and distant signal conditioning, respectively. Temporal derivatives associated with these electrograms suggested increased lead noise with distant signal conditioning, however, as baseline oscillations became pronounced. With the use of fine wires (Fig. 3B), the largest measured SNR with adjacent signal conditioning measured 87.6 and with distant signal conditioning measured 64.1, while using microfabricated sensors (Fig. 3C), the largest measured SNR with adjacent signal conditioning measured 38.9 and with distant signal conditioning measured 28.9. Increases in baseline temporal derivative magnitudes with movement of the buffer amplifiers from the fine wire and microfabricated electrodes were comparable to the increases with movement using coarse wire electrodes.



View larger version (13K):
[in this window]
[in a new window]
 
Fig. 2. Electrode impedance (M{Omega}) as a function of frequency (Hz) in arrays built with coarse wire (A), fine wire (B), and microfabricated sensors (C).

 


View larger version (29K):
[in this window]
[in a new window]
 
Fig. 3. Experimentally recorded unipolar electrograms with the highest identified signal-to-noise ratios (SNRs) measured using coarse wire (A), fine wire (B), and microfabricated sensors (C). Left: electrograms recorded with adjacent signal conditioning. Right: electrograms recorded with distant signal conditioning. Associated temporal derivatives are drawn below the unipolar electrograms. SNR for each unipolar electrogram is indicated on the left side of the trace.

 
Bipolar electrograms and potential gradients. The main reason that high SNRs for unipolar electrograms with microfabricated sensors are needed for improved in vivo Im computation is related to the use of these recordings for surface potential gradient measurements. The importance of fine spatial resolution is highlighted in waveforms assembled from surface potentials recorded in our bidomain simulations and shown in Fig. 4. Figure 4A, left, shows bipolar electrograms recorded with electrode separations ranging from 75 to 750 µm. This range corresponded, approximately, to the range between the finest spatial resolution achieved with our microfabrication strategy and the finest spatial resolution achieved with the coarse wire electrode arrays. As expected, both the widths and peaks of these electrograms increased as the electrodes were separated more widely. With 750-µm separation, an additional feature of the bipolar electrogram was a prolongation of the time over which the electrogram remained at peak potential. This characteristic is consistent with the positioning of recording electrodes outside the width of the electromotive surface of the depolarization wavefront (31), and its presence was associated with marked deviations in estimated Im identified by Witkowski et al. (32). Figure 4A, right, shows bipolar electrograms recorded with electrode separations of 12.5, 25.0, and 37.5 µm, which were finer separations than we achieved with microfabrication. Bipolar electrogram magnitudes fell with finer separation, suggesting high susceptibility of SNRs in experimental recordings at such separation with lead noise. Figure 4B, left, shows the potential gradients associated with the bipolar electrograms recorded using 75- to 750-µm electrode separation. Inaccuracies in both the peaks and widths of the gradient accompanied wider separation. For comparison, Fig. 4B, right, shows the potential gradients associated with the bipolar electrograms recorded with finer spacing. Although three separate waveforms were drawn, the potential gradients are indistinguishable from one another, suggesting sufficiently fine resolution for accurate gradient measurement. Figure 4C shows the maximum potential for bipolar electrograms (left) and the maximum potential gradient (right) recorded at all electrode spacings in the simulations. The range of separations used experimentally with microfabricated sensors, fine wires, and coarse wires are divided by dashed vertical lines in the right panel. Furthermore, the maximum potential gradient measured with 75-µm separation, which was the finest separation achieved with microfabrication, is marked with the filled arrow. Here, at that resolution, we did observe a reduction in the peak gradient by 10% relative to the finest separation available in the simulations, but measurement was clearly superior to that with wider separations. For example, peak gradient reduced by 42% with an electrode separation of 237.5 µm, which was a comparable spacing to the finest available with the fine wire array; and by 81% with an electrode separation of 875.0 µm, which was a comparable spacing to the finest available with the coarse wire array.



View larger version (26K):
[in this window]
[in a new window]
 
Fig. 4. A: simulated bipolar electrograms recorded using different electrode separations (left) showed alongside bipolar electrograms recorded using the finest available separations (right). B: potential gradients measured using the bipolar electrograms from A. C: maximum potential in bipolar electrograms (left) and peak gradients (right) as a function of electrode separation (in µm).

 
Because signal conditioning was adjacent to the microfabricated sensors in our experimental arrangement, we were able to record high-quality bipolar electrograms at 75-µm electrode separation. Figure 5A shows SNRs from all experimentally recorded bipolar electrograms, plotted as a function of interelectrode separation. Although mean SNRs did increase with that separation, as expected, we note that the mean SNR achieved using microfabricated sensors at 75-µm electrode separation exceeded that for the unipolar electrograms recorded using microfabricated sensors. Figure 5B shows coarse wire bipolar electrograms with electrodes separated by 2,590 µm (top), 1,710 µm (middle), and 830 µm (bottom) from one experiment. Consistent with expectations for widely spaced electrodes, peaks and widths for these electrograms shortened as the recording electrodes approached one another. These changes were even more pronounced as the fine wire electrodes were brought to 720 µm (top), 348 µm (middle), and 224 µm (bottom) of one another, as shown in Fig. 5C, and microfabricated sensors were brought to 225 µm (top), 150 µm (middle), and 75 µm (bottom) of one another as shown in Fig. 5D.



View larger version (20K):
[in this window]
[in a new window]
 
Fig. 5. A: SNR as a function of electrode separation (in µm) for all experimentally recorded bipolar electrograms. Bipolar electrograms recorded with coarse wire (B), fine wire (C), and microfabricated sensors (D). Electrode separation for each bipolar electrogram is indicated on the left side of the trace.

 
Second-difference electrograms and SLs. Advantages associated with fine spatial resolution to measure potential gradients are highly pertinent to improved in vivo Im computation because that computation involves determination of spatial differences in directional currents. Because interstitial microimpedances were not measured here, we considered SLs as a surrogate and identified influences of electrode separation on SL that will necessarily impact Im. Figure 6A, left, shows second-difference electrograms recorded with electrode separations ranging from 75 to 750 µm in the simulation. Consistent with our analysis of the bipolar electrograms, second-difference electrogram magnitudes and widths increased as recording electrodes were more widely separated. Figure 6A, right, shows second-difference electrograms recorded with electrode separations of 12.5, 25.0, and 37.5 µm. With such fine spatial resolution, electrogram magnitudes were considerably lower than magnitudes measured with wider electrode spacing. Individual traces are not marked in the panel because of the low magnitudes. Figure 6B shows SLs measured at these same electrode spacings. As with the potential gradients, marked improvements in SL measurements accompanied refinements in spatial resolution. Here, the SL measured with 750-µm electrode separation (left) grossly underestimated the SLs measured with the finest available spatial resolution. Peak-to-peak SL measured with 75-µm electrode separation more closely represented SLs measured with finer spatial resolution, although peak-to-peak magnitude was reduced by 33%. Figure 6C shows peak-to-peak second-difference electrogram (left) and peak-to-peak SL (right) magnitudes for all electrode separations considered in the simulation. Here, it is important to recognize that with electrode separations comparable to the finest available with the fine and coarse wire arrays, peak-to-peak SLs were reduced by 76% and 96%, respectively.



View larger version (24K):
[in this window]
[in a new window]
 
Fig. 6. A: simulated second-difference electrograms recorded using different electrode separations (left) showed alongside second-difference electrograms recorded using the finest available separations (right). B: SLs measured using the second-difference electrograms from A. C: peak-to-peak potential in second-difference electrograms (left) and surface Laplacians (SLs; right) as a function of electrode separation (in µm).

 
Figure 7A shows SNRs for all experimentally recorded second-difference electrograms. Although we observed wide variability in SNR with the most closely spaced microfabricated sensors, mean SNR was comparable to mean SNRs recorded using widely spaced coarse wires. Characteristics of the second-difference electrograms were consistent with those from previous reports and our simulations. Figure 7, B–D, shows second-difference electrograms recorded using coarse wires, fine wires, and microfabricated sensors, respectively. All electrograms were acquired from one experiment. With wide separation and coarse wires (Fig. 7B), the widths and peak-to-peak second differences were much more pronounced than the widths and peak-to-peak second differences with fine wire (Fig. 7C) and microfabricated (Fig. 7D) arrays.



View larger version (22K):
[in this window]
[in a new window]
 
Fig. 7. A: SNR as a function of electrode separation (in µm) for all experimentally recorded second-difference electrograms. Second-difference electrograms recorded with coarse wire (B), fine wire (C), and microfabricated sensors (D). Electrode separation for each second-difference electrogram is indicated on the left side of the trace.

 
To further appreciate the differences between second-difference electrograms and the SLs associated with improved Im computation, we scaled second-difference electrograms recorded with the microfabricated array in three different experiments by the square of the associated electrode separation. Figure 8 shows these SLs, with the records in Fig. 8A being the scaled versions of the second-difference electrograms from Fig. 7D. For reference, the SL measured using coarse wires with 830-µm electrode separation is included below the SLs measured using microfabricated sensors. As in the simulations, peak-to-peak SL diminished with electrode separations from 75 to 150 and 225 µm, suggesting the spacing available with microfabrication likely improves in vivo Im computation. SL available with the coarse wire dramatically underestimates peak-to-peak SL. SLs from the two additional experiments shown in Fig. 8, B and C, share common features with the SLs shown in Fig. 8A, as increases in peak-to-peak SL accompanied refinements in electrode spacing.



View larger version (26K):
[in this window]
[in a new window]
 
Fig. 8. SLs measured in 3 different experiments. A: SLs are from the second-difference electrograms in Fig. 7D recorded with the microfabricated sensors and one second-difference electrogram from Fig. 7B recorded with coarse wire electrodes. Electrode separation for each source electrogram is indicated on the left side of the trace. B and C: SLs are from the second-difference electrograms recorded with the microfabricated sensors in two additional experiments.

 

    DISCUSSION
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The goal of the present study was to assess the feasibility of using microfabricated electrode arrays to measure surface potential components necessary for improved in vivo Im computation. Arrays were assembled in such a way that small electrodes separated on the size scale of individual myocytes were patterned onto one side of an insulated flexible substrate, with trace routings to adjacent signal conditioning on the other side of the substrate profoundly impacting SNRs for unipolar electrograms recordings. By carefully controlling SNRs for unipolar electrogram recordings, we were able to combine surface potentials in bipolar and second-difference electrograms and achieve comparable SNRs to those in electrograms recorded with chloridized silver wires of the type used routinely in cardiac electrophysiological studies. SNR control was critical because surface potential gradient measurements involve scaling of bipolar electrograms by the inverse of electrode separation and SL measurements involve scaling of second-difference electrograms by the inverse of the square of that separation. We believe that the importance of the work presented here is that it is possible to acquire Laplacians on the size scale of cardiac myocytes. Because of the size of the structures involved, it was of great concern that the high impedances and resulting noise would render the measurements unusable. The fact that the SNR of the microfabricated arrays is similar to or, in some cases, better than those of the larger arrays leads us to believe that we will be able to characterize depolarization wavefront expansion at the cellular level with this approach. These findings are significant because they will facilitate device development for improved Im computation in a much wider range of preparations and situations than those considered here.

Microfabrication. Our work is therefore unique compared with previous investigations that focused on the acquisition of unipolar electrograms using microfabricated sensors because we emphasized the potential gradient and SL measurements. Although the precision and consistency of silicon-based arrays used for neural electrophysiological studies (8, 35) is well documented, there have been relatively few attempts to use microfabricated arrays in cardiac electrophysiological studies. In a landmark report, Hofer et al. (7) demonstrated high-quality electrograms recorded from superfused guinea pig papillary muscles using 15 x 15 µm chloridized silver electrodes patterned onto glass with a thin-film technique. Their recordings revealed discontinuous conduction and depolarization wavefront fractionation occurring at a microscopic size scale. More recently, Kim et al. (12) evaluated the suitability of micromachined silicon probes with single or multiple shanks and iridium sensors for intramural unipolar electrogram recordings in perfused rabbit papillary muscles and isolated mouse hearts. Consistent with the present investigation, adjacent signal conditioning was identified as an essential design step for recording with sufficiently high SNR.

Cardiac mapping. Although the use of microfabrication distinguished our work because of the available spatial resolution, it is important to recognize that previous investigations involving surface potential combinations for Im estimation have focused, primarily, on waveform morphology of the resultant electrograms for improved cardiac mapping. Many of those investigations support the use of SL for unambiguous activation time detection. During uniform action potential propagation, Im in one cell includes an initial positive (outward current) phase whose rise is a consequence of capacitive charging of the cell membrane as a depolarization wavefront approaches the cell and whose fall is a consequence of sodium channel activation as the cell reaches threshold. That positive phase is followed by a negative (inward current) phase over which sodium channels inactivate. Assuming the time of Im zero crossing to be correlated with peak sodium current therefore provides a measure of cellular activation that is presumably superior to standard measures based on analyses of unipolar electrogram waveform characteristics. The unipolar electrogram includes contributions from local and distant sources that complicate activation time detection in fractionated signals, leading to ambiguities in the representation of depolarization wavefront expansion with isochrone maps (1, 11). The second-difference electrogram is suitable for this purpose because the time of its zero crossing is largely independent of directional differences in the interstitial microimpedances. Superiority for SL-based isochrone map construction was therefore suggested by Witkowski et al. (32) and Coronel et al. (3), with a detailed comparison of isochrone maps assembled using unipolar electrograms recorded at 1- to 2-mm electrode spacing from canine epicardium being completed by Punske et al. (25), who found maps assembled using the time of SL zero crossing correlated well with maps assembled using the time of peak surface potential gradient magnitude under conditions where errors were observed in maps assembled using the time of the minimum derivative of unipolar electrogram. Although the focus here was not on activation time detection, we do note likely advantages to using microfabricated sensors for this purpose because peak-to-peak SL magnitude increases so dramatically with fine spatial resolution.

Although both Witkowski et al. (33) and Coronel et al. (3) recognized the importance of improved activation time detection available from zero crossing times, each group found additional features of waveform morphology illustrative in understanding the spatial and temporal evolution of these arrhythmias. For example, Coronel et al. (3) identified positive SLs at sites of depolarization wavefront collision, negative SLs at sites of depolarization wavefront initiation, and sustained positive or negative baseline SLs in regions of conduction block during VF mapping. Witkowski et al. (33) systematically compared the ratio of the area under the estimated inward Im curve to the area under the estimated outward Im curve during VF and found that ratio was balanced when surface unipolar potential deflections resulted from local cellular activation identified using Vm-dependent fluorescence collected in an adjacent optical fiber. Surface unipolar deflections associated with electrotonic interactions showed marked reduction in the inward current as indexed by its area. Routine segmentation of active from passive deflections was therefore available. Our findings suggest finer spatial resolution would provide additional detail, with improved activation sequence reconstruction as a likely consequence.

Electrical source-load interactions. While improvements in cardiac mapping represent one way in which data of the type we analyzed can benefit from the use of microfabrication-based strategies, investigations in which Im estimates have been used as indexes for electrical source-load relationships suggest Im measurement will improve analyses of those relationships because they will be quantified. For example, de Groot et al. (4) recently used SL measurements from Langendorff-perfused rabbit hearts in combination with voltage-clamp experiments in isolated myocytes and current-clamp recordings from cell pairs to support the specificity of gap junctional uncoupling with carbenoxolone. Those investigators assumed maintenance of Vm distributions after carbenoxolone perfusion and interpreted a 50% reduction in SL amplitudes assembled from second-difference electrograms recorded using 0.5- to 1.0-mm spacing as being a consequence of gap junctional uncoupling alone. Support for the assumption regarding Vm included voltage-clamp experiments that demonstrated minimal influence of carbenoxolone on L-type calcium current, delayed rectifier potassium current, or inward rectifier potassium current and action potential recordings that showed maintenance of upstroke velocity and consistent action potential durations at 20%, 50%, and 90% repolarization. Support for gap junctional uncoupling as opposed to increased interstitial microimpedance included reduced coupling conductance measured during current clamps in cell pairs. They argued that the decrease in SL amplitude reflected gap junction uncoupling alone because Vm and tissue impedance remained constant in their experiments. Interstitial microimpedance data, however, were not provided.

Integration of microimpedance data. We view the integration of interstitial microimpedance data as a valuable and straightforward next step because feasibility of surface potential gradient and SL measurements that contribute to improved in vivo Im computation was successfully implemented here. Microfabrication will be advantageous for this purpose because it will allow us to integrate electrodes just outside the interrogation region for use in stimulation. In a recent report (24), we showed that both the intracellular and interstitial cardiac microimpedances can be measured by analyzing a set of interstitial potential differences recorded centrally during multisite stimulation with a set of interstitial electrodes bounding the recording pair. Constant microimpedances were prescribed to one-dimensional models that included LRd membrane equations, and simulations involving 29 different electrode combinations allowed interstitial and intracellular microimpedance measurement at errors below 1%. A noteworthy aspect of that approach was the stable and independent measurement of go,x and of gi,x. Because no intracellular access was required, Vm recording was unnecessary. Highly accurate go,x measurements were obtained because fine spacing allowed precise four-electrode impedance measurements, consistent with theoretical descriptions by Plonsey and Barr (19). Those investigators showed that interstitial potential distributions resulting from current injection and removal in an idealized anisotropic passive bidomain model depended critically on stimulating electrode separation. With separation at 20% of the resting space constant, no intracellular current was established as the spatial distribution of transmembrane potential was equal and opposite to the distribution of interstitial potential. Using microfabrication, we anticipate bounding the set of recording electrodes necessary for the surface potential gradient measurements with stimulating electrodes separated from one another on a size scale consistent with the Plonsey and Barr (19) requirements. Such an arrangement would allow straightforward measurements of go,x and of go,y to be used in combination with the surface potential gradient terms in Eq. 1 to further facilitate in vivo Im computation.

Limitations. In assessing our findings, it is important to recognize certain limitations. 1) We compared SNRs between unipolar electrograms recorded with adjacent and distant signal conditioning for the different types of electrodes but made no attempt to shield lead wires for the distant signal conditioning recordings. Therefore, associated noise contributions in the distant signal conditioning recordings were likely higher than contributions to be expected with shielding. 2) Although all electrograms were recorded during epicardial stimulation adjacent to the electrode arrays, the electrodes themselves were not necessarily oriented along or across epicardial fibers. As a consequence, depolarization wavefronts expanding through the interrogation regions had varying amounts of curvature. Using detailed theoretical modeling, Leon and Witkowski (16) compared the shapes, magnitudes and durations of their estimated Im to the Im calculated in simulations. With decremental conduction, conduction block, depolarization wavefront initiation, and depolarization wavefront collision, those correlations decreased systematically, consistent with deviation from the underlying assumptions formulated in the initial Witkowski et al. (32) analyses. By comparison, they found high correlations during uniform depolarization wavefront expansion through the interrogation region. While their correlations suggest the moderate variability in depolarization wavefront curvature that was likely associated with our approach minimally influenced our overall findings, that influence was not demonstrated here. 3) We did not reduce spacing in the microfabricated arrays to the extent suggested by our simulations. While our findings strongly support the feasibility of using microfabricated sensors for the necessary component potential gradients, further refinements in electrode separation will likely be necessary for improved in vivo Im computation.


    GRANTS
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
This work was supported by National Heart, Lung, and Blood Institute Awards HL-50537, HL-67728, HL-67961, and HL-77607.


    FOOTNOTES
 

Address for reprint requests and other correspondence: A. E. Pollard, Cardiac Rhythm Management Laboratory, Univ. of Alabama at Birmingham, Volker Hall B140, 1670 Univ. Blvd., Birmingham, AL 35294 (e-mail: pollard{at}crml.uab.edu)

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 GENERAL THEORY
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 

  1. Berbari EJ, Lander P, Scherlag BJ, Lazzara R, and Geselowitz DB. Ambiguities of epicardial mapping. J Electrocardiol Suppl 24: 16–20, 1991.
  2. Clerc L. Directional differences of impulse spread in trabecular muscle from mammalian heart. J Physiol 255: 335–346, 1976.[Abstract/Free Full Text]
  3. Coronel R, Wilms-Schopman JG, de Groot JR, Janse MJ, Van Capelle FJL, and De Bakker JMT. Laplacian electrograms and the interpretation of complex ventricular activation patterns during ventricular fibrillation. J Cardiovasc Electrophysiol 11: 1119–1128, 2000.[Web of Science][Medline]
  4. de Groot JR, Veenstra T, Verkerk AO, Wilders R, Smits JP, Wilms-Schopman FJ, Wiegerinck RF, Bourier J, Belterman CN, Coronel R, and Verheijck EE. Conduction slowing by the gap junctional uncoupler carbenoxolone. Cardiovasc Res 60: 288–297, 2003.[Abstract/Free Full Text]
  5. Fast VG and Kléber AG. Microscopic conduction in cultured strands of neonatal rat heart cells measured with voltage-sensitive dyes. Circ Res 73: 914–925, 1993.[Abstract/Free Full Text]
  6. Giles WR and Imaizumi Y. Comparison of potassium currents in rabbit atrial and ventricular cells. J Physiol 405: 123–145, 1988.[Abstract/Free Full Text]
  7. Hofer E, Urban G, Spach MS, Schafferhofer I, Mohr G, and Platzer D. Measuring activation patterns of the heart at a microscopic size scale with thin-film sensors. Am J Physiol Heart Circ Physiol 266: H2136–H2145, 1994.[Abstract/Free Full Text]
  8. Hoogerwerf AC and Wise KD. A three-dimensional microelectrode array for chronic neural recording. IEEE Trans Biomed Eng 41: 1136–1146, 1994.[CrossRef][Web of Science][Medline]
  9. Hund TJ, Kucera JP, Otani NF, and Rudy Y. Ionic charge conservation and long-term steady state in the Luo-Rudy dynamic cell model. Biophys J 81: 3324–3331, 2001.[Web of Science][Medline]
  10. Hund TJ and Rudy Y. Determinants of excitability in cardiac myocytes: mechanistic investigation of memory effect. Biophys J 79: 3095–3104, 2000.[Web of Science][Medline]
  11. Ideker RE, Smith WM, Blanchard SM, Reiser SL, Simpson EV, Wolf PD, and Danieley ND. The assumptions of isochronal cardiac mapping. PACE 12: 456–478, 1989.
  12. Kim CS, Ufer S, Seagle CM, Engle CL, Nagle HT, Johnson TA, and Cascio WE. Use of micromachined probes for the recording of cardiac electrograms in isolated heart tissues. Biosens Bioelectron 19: 1109–1116, 2004.[CrossRef][Web of Science][Medline]
  13. Kléber AG and Rieger CB. Electrical constants of arterially perfused rabbit papillary muscle. J Physiol 385: 307–324, 1987.[Abstract/Free Full Text]
  14. Kucera JP, Kléber AG, and Rohr S. Slow conduction in cardiac tissue. II. Effects of branching tissue geometry. Circ Res 83: 795–805, 1998.[Abstract/Free Full Text]
  15. Kucera JP and Rudy Y. Mechanistic insights into very slow conduction in branching cardiac tissue. A model study. Circ Res 89: 799–806, 2001.[Abstract/Free Full Text]
  16. Leon LJ and Witkowski FX. Calculation of transmembrane current from extracellular potential recordings: A model study. J Cardiovasc Electrophysiol 6: 379–390, 1995.[Medline]
  17. Luo CH and Rudy Y. A dynamic model of the cardiac ventricular action potential. I. Simulations of ionic currents and concentration changes. Circ Res 74: 1071–1096, 1994.[Abstract/Free Full Text]
  18. Malkin RA and Pendley BD. Construction of a very high-density extracellular electrode array. Am J Physiol Heart Circ Physiol 279: H437–H442, 2000.[Abstract/Free Full Text]
  19. Plonsey R and Barr RC. The four-electrode resistivity technique as applied to cardiac muscle. IEEE Trans Biomed Eng 7: 983–986, 1982.
  20. Plonsey R and Barr RC. Interstitial potentials and their change with depth into cardiac tissue. Biophys J 51: 547–555, 1987.[Web of Science][Medline]
  21. Plonsey RC and Barr RC. A critique of impedance measurements in cardiac tissue. Ann Biomed Eng 14: 307–322, 1986.[CrossRef][Web of Science][Medline]
  22. Polimeni PI, Williams S, and Weisman H. Application of automatic electrotonic image analyzer to the measurement of myocardial extracellular space. Comput Biomed Res 16: 522, 1983.[CrossRef][Web of Science][Medline]
  23. Pollard AE, Cascio WE, Fast VG, and Knisley SB. Modulation of triggered activity by uncoupling in the ischemic border: a model study with phase 1b-like conditions. Cardiovasc Res 56: 381–392, 2002.[Abstract/Free Full Text]
  24. Pollard AE, Smith WM, and Barr RC. Feasibility of cardiac microimpedance measurement using multisite interstitial stimulation. Am J Physiol Heart Circ Physiol 287: H2402–H2411, 2004.[Abstract/Free Full Text]
  25. Punske BB, Ni Q, Lux RL, MacLeod RS, Ershler PR, Dustman TJ, Allison MJ, and Taccardi B. Spatial methods of epicardial activation time determination in normal hearts. Ann Biomed Eng 31: 781–792, 2003.[CrossRef][Web of Science][Medline]
  26. Roth BJ. Action potential propagation in a thick strand of cardiac muscle. Circ Res 68: 162–173, 1991.[Abstract/Free Full Text]
  27. Roth BJ, Gielen FLH, and Wikswo JP. Spatial and temporal frequency-dependent conductivities in volume-conductor calculations for skeletal muscle. Math Biosci 88: 159–189, 1988.[CrossRef]
  28. Shaw RM and Rudy Y. Electrophysiologic effects of acute myocardial ischemia. A mechanistic investigation of action potential conduction and conduction failure. Circ Res 80: 124–138, 1997.[Abstract/Free Full Text]
  29. Shaw RM and Rudy Y. Ionic mechanisms of propagation in cardiac tissue. Roles of sodium and L-type calcium currents during reduced excitability and decreased gap junction coupling. Circ Res 81: 727–741, 1997.[Abstract/Free Full Text]
  30. Spach MS, Miller WT, Geselowitz DB, Barr RC, Kootsey JM, and Johnson EA. The discontinuous nature of propagation in normal canine cardiac muscle evidence for recurrent discontinuities of intracellular resistance. Circ Res 48: 39–54, 1981.[Free Full Text]
  31. Vander Ark CR and Reynolds EW Jr. An experimental study of propagated electrical activity in the canine heart. Circ Res 26: 451–460, 1970.[Abstract/Free Full Text]
  32. Witkowski FX, Kavanagh KM, Penkoske PA, and Plonsey R. In vivo estimation of cardiac transmembrane current. Circ Res 72: 424–439, 1993.[Abstract/Free Full Text]
  33. Witkowski FX, Plonsey R, Penkoske PA, and Kavanagh KM. Significance of inwardly directed transmembrane current in determination of local myocardial electrical activation during fibrillation. Circ Res 74: 507–524, 1994.[Abstract/Free Full Text]
  34. Wolf PD, Rollins D, Simpson E, Smith WM, and Ideker RE. A 528 channel system for the acquisition and display of defibrillation and electrocardiographic potentials. In: Proceedings of Computers in Cardiology. IEEE Computer Society, 1993, p. 125–128.
  35. Yoon TH, Hwang EJ, Shin DY, Park SI, Oh SJ, Jung SC, Shin HC, and Kim SJ. A micromachined silicon depth probe for multichannel neural recording. IEEE Trans Biomed Eng 47: 1082–1087, 2000.[CrossRef][Web of Science][Medline]



This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. E. Pollard and R. C. Barr
Cardiac microimpedance measurement in two-dimensional models using multisite interstitial stimulation
Am J Physiol Heart Circ Physiol, May 1, 2006; 290(5): H1976 - H1987.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
289/6/H2468    most recent
00570.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wiley, J. J.
Right arrow Articles by Pollard, A. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wiley, J. J.
Right arrow Articles by Pollard, A. E.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2005 by the American Physiological Society.