Am J Physiol Heart Circ Physiol 290: H1558-H1565, 2006. First published November 18, 2005; doi:10.1152/ajpheart.00928.2005
0363-6135/06 $8.00
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
290/4/H1558    most recent
00928.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Choy, J. S.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Choy, J. S.
Right arrow Articles by Kassab, G. S.

Nonuniformity of axial and circumferential remodeling of large coronary veins in response to ligation

Jenny Susana Choy,1 Quang Dang,1 Sabee Molloi,2 and Ghassan S. Kassab1

Departments of 1Biomedical Engineering and 2Radiological Sciences, University of California, Irvine, California

Submitted 31 August 2005 ; accepted in final form 16 November 2005


    ABSTRACT
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The pressure-induced remodeling of coronary veins is important in coronary venous retroperfusion. Our hypothesis is that the response of the large coronary veins to pressure overload will depend on the degree of myocardial support. Eleven normal Yorkshire swine from either sex, weighing 31–39 kg, were studied. Five pigs underwent ligation of the left anterior descending (LAD) vein, and six served as sham-operated controls. The ligation of the coronary vein caused an increase in pressure intermediate to arterial and venous values. After 2 wk of ligation, the animals were euthanized and the coronary vessels were perfusion-fixed with glutaraldehyde. The LAD vein was sectioned, and detailed morphometric measurements were made along its length from the point of ligation near the base down to the apex of the heart. The structural remodeling of the vein was circumferentially nonuniform because the vein is partially embedded in the myocardium; it was also axially nonuniform because it is tethered to the myocardium to different degrees along its axial length. The wall area was significantly larger in the experimental group, whereas luminal area in the proximal LAD vein was significantly smaller in the same group compared with sham-operated controls. The wall thickness-to-radius ratio was also significantly larger in the experimental group in proportion to the increase in pressure. The major conclusion of this study is that the response of the vein depends on the local wall stress, which is, in part, determined by the surrounding tissue. Furthermore, the geometric remodeling of the coronary vein restores the circumferential stress to the homeostatic value.

arterialization; pressure-overload; retroperfusion; wall stress; surrounding tissue


THERE IS ABUNDANT LITERATURE on the effect of pressure overload on structural and mechanical remodeling of arteries (see review in Ref. 13). Studies (9) on the remodeling of the veins in response to pressure overload, however, are much less common. Indeed, we are unaware of any studies on the remodeling of the coronary veins in response to pressure overload. This is unfortunate, however, because pressure-induced remodeling is a central issue in such therapeutic approaches as chronic coronary retroperfusion (20, 21). The objective of the present study is to fill in this gap to understand the mechanical adaptation of the large coronary veins in response to elevated pressures.

Our hypothesis is that an increase in left anterior descending (LAD) vein pressure will lead to remodeling or arterialization of the veins, including an increase in wall thickness-to-radius ratio, which will decrease the circumferential wall stress. An additional hypothesis is that the structural remodeling will be circumferentially and axially nonuniform because the LAD vein is partially embedded in the myocardium circumferentially and is tethered to the myocardium to various degrees along its axial length. Hence, we will determine the structural remodeling of the LAD vein circumferentially and along its axial length.

The present findings confirm these hypotheses and show significant thickening of the venous wall to restore the intramural circumferential stress. Furthermore, the data show that the LAD vein developed intimal thickening (inward remodeling) only in the absence of myocardial support and that significant medial thickening (hypertrophic remodeling) occurs to restore the intramural circumferential stress. The present study clarifies the structural remodeling in the coronary veins after ligation and provides a rationale for the development of a coronary retroperfusion strategy that avoids long-term atherosclerotic changes.


    METHODS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The choice of the present animal model was based on the similarities between human and swine coronary vessels (10). This study was conducted in accordance with national and local ethical guidelines, including the Institute of Laboratory Animal Research Guide; the Public Health Service policy; and the Animal Welfare Act and approved by the Institutional Animal Care and Use Committee of the University of California, Irvine.

Animal preparation. Eleven normal Yorkshire swine of either sex with body weight of 31–39 kg were studied. The animals were fasted overnight; ketamine (20 mg/kg) and atropine (0.05 mg/kg) were administered intramuscularly before endotracheal intubation. The animals were ventilated with the use of a mechanical respirator, and general anesthesia was maintained with 1 to 2% isoflurane and oxygen. The chest was opened through a left lateral, fourth-intercostal-space thoracotomy, and an incision was made in the pericardium with the creation of a sling to support the heart. The LAD vein was located and isolated close to the great cardiac vein, and a suture was placed around the vessel as shown in Fig. 1. An introducer was used to puncture the vein to measure the venous pressure before ligation. With the catheter inside the vessel and fixed to the surface of the heart, the ligature was tightened to measure the increase in pressure after ligation. The catheter was then withdrawn, and the ligation was made permanent to completely occlude the flow through the vein. The chest was then closed in a standard manner, and the animals were allowed to recover. In five animals, the vein was ligated, whereas in six animals, the suture was not tightened and the animals served as sham-operated controls.


Figure 1
View larger version (107K):
[in this window]
[in a new window]
 
Fig. 1. Illustration of left anterior descending (LAD) vein showing point of ligation and definition of fractional longitudinal position (FLP).

 
The experimental and sham-operated animals were recovered for 15 days. The animals were administered cefazolin (500 mg im) and buprenorphine (0.03 mg/kg) twice a day for the prevention of infection and the management of pain, respectively. At the scheduled time, the animals were anesthetized as described above. The blood pressure was measured through a carotid artery, and anticoagulation was induced with heparin (100 IU/kg) through a jugular vein. The animals were then deeply anesthetized followed by an injection of a saturated KCl solution through the jugular vein to arrest the heart. The aorta was clamped to keep air bubbles from entering the coronary arteries, and the heart was excised and placed in a saline solution. The LAD artery, the right coronary artery, and the left circumflex artery were cannulated under saline to avoid air bubbles and perfused with cardioplegic solution to flush out the blood. The heart was then perfused and fixed with 1 liter of 6.25% glutaraldehyde solution at 1,100 mosM and a pressure of 100 mmHg. The fixed hearts were kept in the refrigerator until the day of histological preparation.

Histological preparation of LAD vein. The LAD vein was cut perpendicularly to the long axis of the vessel into 3- to 4-mm serial segments from the point of ligation to the apex of the heart where the vessel had a diameter of ~0.5 mm. A coordinate system was set up such that the fractional longitudinal position (FLP) at the ligature was defined as 0 and that at the distal end (0.5 mm in diameter) was defined as 1, as shown in Fig. 1. The proximal position of every ring was recorded, and each segment was rinsed three times with a buffer solution and processed by dehydration in increasing concentrations of alcohol (70%, 80%, 95%, and 100%). The segments were then embedded in either JB-4 (odd segments) or paraffin (even segments). All samples were processed by using a microtome (HM 340 E from Microm). The JB-4 embedded segments were cut into 3-µm sections, mounted on glass slides, and stained with toluidine blue for morphometric measurements. The paraffin-embedded segments were cut into 5-µm sections, mounted on glass slides, and deparaffinized and stained with Verhoeff's elastic stain to study the vessel structure. Photographs of the histological cross-sections of each segment were taken with the use of a light microscope (Nikon) and a Spot Insight Color Digital Camera (Diagnostic Instruments).

Morphometric measurements. Photographs of histological cross-sections of the LAD vein were analyzed. The proximal portion of the vessel faced upstream, and the distal portion faced downstream as shown in Fig. 2. For each photograph, the following measurements were made on the proximal portion of the vessel: inner and outer circumferences; inner, outer, and wall areas; and intimal and wall thickness at twelve equally spaced locations (0°, 30°, 60°,... 300°, and 330° in a clockwise direction around the circumference of the vessel). The 90° line corresponds to the center of the anterior portion, and the 270° line corresponds to the center of the posterior portion of the vessel in a cross-sectional view as seen in Fig. 2. Hence, the anterior portion of the vessel, surrounded by connective tissue, ranges from 0–180°, whereas the posterior region (surrounded by myocardium) corresponds to 180–360°. Intimal thickness was measured by using the internal elastic lamina as the line of demarcation between the tunica intima and the media adventitia. All measurements were made with the use of SigmaScan Pro 5 software.


Figure 2
View larger version (21K):
[in this window]
[in a new window]
 
Fig. 2. Schematic representation of coordinate system used to measure several parameters on a cross-section of the vein.

 
Data analysis. The position along the vein was normalized with respect to the total length, and the results were expressed in terms of the FLP, ranging from 0 to 1 (Fig. 1). The data for both the independent (FLP) and dependent variables (diameter, wall thickness, area, etc.) were then divided into 20 equal intervals: 0–0.05, 0.06–0.10,... 0.91–0.95, 0.96–1.0.

Statistical analysis. All morphometric data were expressed as means ± SE. The axial variations were examined with a two-way ANOVA. Student's t-test was also used to detect possible differences between animals.


    RESULTS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The phasic and mean pressures in the LAD vein before and after ligation are shown in Fig. 3A from one animal. The mean pressure, averaged over all the animals, in the LAD vein was ~20 mmHg before the ligation and 50 mmHg after the ligation (P < 0.05), as shown in Fig. 3B.


Figure 3
View larger version (27K):
[in this window]
[in a new window]
 
Fig. 3. A: phasic pressure in LAD vein before and after ligation in one animal. Solid curve represents mean value of phasic trace. B: mean pressure before and after ligation average over each group of animals.

 
The length of the LAD vein was 74.0 ± 9.2 mm in the experimental group and 76.9 ± 7.8 mm in the sham-operated control group (P = 0.59). All venous tissue samples from the experimental group ranged in diameter from 2.2 ± 0.08 (FLP, ~0) to 0.50 ± 0.14 mm (FLP, ~1). Veins in the sham-operated control group ranged from 3.04 ± 0.3 (FLP, ~0) to 0.64 ± 0.26 mm (FLP, ~1). These differences were statistically significant in the proximal portion of the LAD vein (FLP < 0.20, P = 0.03).

Figure 4 shows histological sections of the LAD vein from experimental (Fig. 4, A and C) and sham-operated (Fig. 4, B and D) groups at 90° and 270°. The increase in intimal and wall thickness in the experimental group is obvious. The thicker intima, however, is restricted to the anterior portion of the vessel (0–180°), especially at 90° (Fig. 4A). Figure 5 shows a paraffin section of the intima-thick region of the epicardial LAD vein revealing increased number of cells (many nuclei), as well as an inflammatory process including macrophages and neutrophils.


Figure 4
View larger version (119K):
[in this window]
[in a new window]
 
Fig. 4. A: histological changes of LAD vein after ligation at FLP of ~0.4 showing intimal (IT) and medial thickening in anterior portion (90°) of vessel (toluidine blue at x200). IEL, internal elastic lamina; M, media; A, adventitia. B: histological section of the LAD vein at FLP of ~0.4 in sham-operated control group showing normal wall thickness and no intimal thickening in anterior portion (90°) of vessel (toluidine blue at x200). C: histological changes of LAD vein after ligation at FLP of ~0.4 showing wall thickening in posterior portion (270°) of vessel (toluidine blue at x200). D: histological section of LAD vein at FLP of ~0.4 in sham-control group showing normal wall thickness and no intimal thickening in posterior portion (270°) of vessel (toluidine blue at x200).

 

Figure 5
View larger version (128K):
[in this window]
[in a new window]
 
Fig. 5. Histological section of anterior portion (90°) of LAD vein in experimental group at FLP of ~0.18 showing many inflammatory cells in intima (toluidine blue at x400). F, fibroblasts; Ma, macrophage; N, neutrophils.

 
The mean wall and intimal thickness for the experimental and sham-operated groups are shown in Fig. 6, A and C, and Fig. 6, B and D, respectively. The most anterior portion of the vessel (at 90°, with no surrounding myocardial tissue) showed the largest change in total wall thickness (~300 µm at FLP of ~0 to ~50 µm at FLP of ~1). The most posterior portion of the vessel (at 270°, surrounded by the myocardium), however, showed the smallest change in wall thickness (~125 µm at FLP of ~0 to ~20 µm at FLP of ~1) as shown in Fig. 6, A and B. Intimal thickness was 20 to 25 times larger in the experimental group at FLP of ~0 compared with that of the sham-operated group. Furthermore, the most anterior portion of the vein showed the largest intimal thickness (~150 µm at FLP of ~0 to ~10 µm at FLP of ~1), whereas the most posterior portion of the vessel showed the smallest change (~30 µm at FLP of ~0 to ~10 µm at FLP of ~1) as shown in Fig. 6, C and D. The cross-section of the vessel in the experimental group was also represented in cross-sectional diagrams at FLP of ~0.025, 0.225, 0.475, 0.725, and 0.975 and in the sham-operated group at FLP of ~0.025 (Fig. 7, top, right).


Figure 6
View larger version (36K):
[in this window]
[in a new window]
 
Fig. 6. A: wall thickness in experimental group at various points along circumference of vein. B: wall thickness in sham-operated control group. C: intimal thickness in experimental group. D: intimal thickness in sham-operated control group.

 

Figure 7
View larger version (27K):
[in this window]
[in a new window]
 
Fig. 7. Schematic representation of cross-sections of vein at different FLP. The first two (top) compare thickness at same FLP in the experimental and sham-operated groups, respectively. Other cross-sections show remodeled vein at various values of FLP.

 
The values for the wall area were significantly different between the two groups, especially in the proximal 20% of the vessel length (almost double) as seen in Fig. 8. In the experimental group, the values ranged from 1.1 (FLP, ~0) to 0.04 mm2 (FLP, ~1), whereas in the sham-operated group, they ranged from 0.7 (FLP, ~0) to 0.02 mm2 (FLP, ~1) (P < 0.05).


Figure 8
View larger version (17K):
[in this window]
[in a new window]
 
Fig. 8. Variation in wall area along FLP of vessels in experimental and sham-operated control groups.

 
The luminal area was significantly smaller in the experimental group (P < 0.001) and more evident in the proximal 15% of the vessel length; i.e., 2 to 3 times smaller, as shown in Fig. 9. In the experimental group, the values ranged from 2 (FLP, ~0) to 0.19 mm2 (FLP, ~1), whereas in the sham-operated group, they ranged from 7 (FLP, ~0) to 0.3 mm2 (FLP, ~1).


Figure 9
View larger version (17K):
[in this window]
[in a new window]
 
Fig. 9. Variation in luminal area along FLP of vessels in experimental and sham-operated control groups. *P < 0.001.

 
The wall thickness-to-radius ratio was 1.5 to almost 5 times larger in the experimental group (P < 0.001); the values ranged from 0.24 (FLP, ~0) to 0.054 (FLP, ~1), whereas in the sham-operated group, they ranged from 0.050 (FLP, ~0) to 0.018 (FLP, ~1), as shown in Fig. 10. The mean circumferential stress was approximated by Laplace's equation as the quotient of pressure and wall thickness-to-radius ratio. We found the mean values to be 38 ± 26 and 43 ± 18 kPa for the experimental and sham-operated groups, respectively. The differences were not statistically significant (P = 0.72).


Figure 10
View larger version (21K):
[in this window]
[in a new window]
 
Fig. 10. Variation of the wall thickness-to-radius ratio along FLP of vessels in experimental and sham-operated control groups.

 
The total (lumen plus wall) area was significantly smaller in the experimental group (P < 0.001), particularly in the proximal segments of the vessel length as shown in Fig. 11. The values in the experimental group ranged from 2.9 (FLP, ~0) to 0.2 mm2 (FLP, ~1), whereas in the sham-operated group, they ranged from 7.7 (FLP, ~0) to 0.32 mm2 (FLP, ~1).


Figure 11
View larger version (17K):
[in this window]
[in a new window]
 
Fig. 11. Variation of total (lumen plus wall) area along FLP of vessels in experimental and sham-operated control groups.

 

    DISCUSSION
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
The major finding of the present study is that the pressure increase induced by the ligation of the LAD vein leads to remodeling or arterialization of the vein. The structural remodeling is circumferentially and axially nonuniform because the vein is partially embedded in the myocardium circumferentially and is tethered to the myocardium to various degrees along its axial length.

Effect of venous ligation on pressure waveform and flow distribution. If the coronary venous system consisted of only epicardial drainage into the coronary sinus, then the ligation of a vein would result in a stagnation of flow and an increase in venous pressure to arterial levels. On the other hand, if the coronary venous system consisted of only subendocardial drainage into numerous thebesian vessels, then the ligation of a vein would result in an increase in pressure to capillary levels or below. In actuality, the coronary venous system consists of both a major epicardial sinusal venous system and many subendocardial thebesian vessels. Furthermore, there are communications or interconnections within each system and in between the two systems (14). Hence, ligation of a coronary vein is expected to raise the venous pressure to a value intermediate to capillary and arterial pressures, i.e., ~50 mmHg as documented in the present study (Fig. 3B). Furthermore, the pulse pressure is quite large during the cardiac cycle as seen in Fig. 3A. In systole, the peak pressure approaches arterial pressure because the communication between the sinusal and thebesian vessels is interrupted because the thebesian vessels, which are subendocardial, may be compressed by the high extravascular pressure. Hence, the increase in pressure is a measure of the degree of venting of the LAD vein through the interconnections between the sinusal veins and Thebesian system. If the ligation were made at a different axial position along the vein, a different pressure increase would be expected. In the present study, we systematically ligated the LAD vein in all hearts (at approximately the same point) where the LAD vein curves into the great cardiac vein as shown in Fig. 1.

The occlusion of a coronary vein not only increases the venous pressure but also causes a redistribution of the flow to the numerous communications between the various segments of the coronary circulation. Scharf et al. (22) found that the occlusion of the coronary sinus caused a redistribution of the venous flow to other channels emptying in the right heart. Furthermore, they found that the distribution of venous outflow changed when the pressure exceeded 9 mmHg. Hence, we expect significant redistribution of blood flow in the present experimental model.

Effect of ligation and pressure overload on coronary veins. The vasculature is an adaptable structure that is capable of biochemical, architectural, and functional adjustments in response to changes in mechanical stimuli. An increase in blood pressure leads to an increase in tensile stress, which is a stimulus for vascular growth and remodeling (12). In in vitro studies (6), it has been shown that venous smooth muscle cells are much more responsive to mechanical stimuli than their arterial counterparts. Furthermore, if the increase in circumferential stress is too large and abrupt, it can also elicit an injury response. The injury response includes neointimal hyperplasia as a result of the proliferation and migration of the smooth muscle cells into the intima. The proliferation is followed by an increase in connective tissue matrix, which results in the thickening of the medial and intimal layers. Specifically, previous studies (18, 26) in dogs have shown that an anastomotic occlusion occurs in venous retroperfusion due to fibrous proliferation. There may be species differences, however, because Chiu and Mulder (4) did not observe venous obliteration in the sheep model.

Occlusion of the LAD vein resulted in a significant increase in pressure and hence circumferential stress, which induces structural changes of the venous wall, such as neointimal hyperplasia and wall hypertrophy. At a FLP of ~0, the LAD vein is partially tethered by the myocardium. If we assume that the tethering is negligible, we can use Laplace's equation to approximate the circumferential stress. Laplace's equation states that the mean circumferential stress in the vessel wall is directly proportional to the blood pressure and inversely proportional to the vessel thickness-to-radius ratio. Therefore, an increase in blood pressure causes an increase in the mean circumferential stress. In pure hypertension, it is expected that the increase in wall thickness-to-radius ratio will occur in proportion to the increase in pressure, such that the circumferential stress is normalized (19, 2325). This is in agreement with our present findings for the inward and hypertrophic remodeling of the LAD vein.

Recently, Hayashi et al. (9) have examined in rabbits the biomechanical response of the femoral vein to a chronic elevation of blood pressure. In response to a constriction of the iliac vein, they found that the femoral vein remodels to pressure overload. Their data show that the increase in wall thickness-to-radius ratio of the experimental vein normalized the circumferential stress to that of a normal vein. Furthermore, they found that the vascular tone and contractility were increased by the elevation of blood pressure, which suggests functional arterializations of the venous vessels.

Effect of surrounding tissue on venous remodeling. The intramural stresses and strains in blood vessels depend not only on the mechanical loading and the microstructural components of the vessel wall, such as collagen and elastin fibers, smooth muscle cells, and ground substances, but also on the mechanical coupling with neighboring tissue. All blood vessels receive some perivascular support from the surrounding tissue. The epicardial coronary blood vessels are partially embedded, whereas the intramyocardial vessels are fully embedded into the myocardium (8). Our group (28) has previously investigated the effect of radial tissue constraint on the intramural stresses and strains of coronary arteries. The radial tissue constraint was imposed in terms of zero-displacement boundary conditions to constrain the outer surface of the vessel to different extents by the myocardium. A finite element analysis showed that even a small external compression (10%) of the myocardium on the coronary artery causes a large reduction in circumferential stress and strain (28). Hence, we expect the stress to be higher in the anterior than posterior portion of the venous vessel wall during pressure overload. This is consistent with the intimal hyperplasia observed on the anterior side in the present study. The intimal hyperplasia disappears when the vessel becomes completely embedded into the myocardium. Hence, the myocardium protects the blood vessel from increased stress. This is a novel documentation of the nonuniformity of structural remodeling in response to nonuniformity in the circumferential stress distribution. Hence, there is a direct connection between the local stress and the response of the vessel wall. Future study is needed in which a detailed three-dimensional analysis of the stress distribution in the LAD vein under normotensive and hypertensive conditions will quantify the relation between local stress (cause) and structural response (effect).

Possible mechanism of remodeling. Among the many molecules implicated in vascular remodeling is tissue-type transglutaminase (tTG). tTG is an enzyme that has many functions, among which is the introduction of isopeptide linkages within a single polypeptide or between different polypeptides. Recently, Bakker et al. (1) found that tTG plays an important role in remodeling of small arteries. Their in vivo data showed that inward remodeling observed with low blood flow may be reversed by inhibiting the effects of the enzyme. Their in vitro experiments also showed that exogenous tTG induced inward remodeling on vessels pressurized at 60 mmHg. Langille and Dajnowiec (15) underscore the relationship between tTG and inward arterial remodeling.

Critique of methods. Laplace's equation is only an approximation, because the mean circumferential stress is likely to be reduced due to the myocardial support (8, 27). Furthermore, because the vessel is partially tethered (posterior but not anterior), we expect the stress distribution in the wall to vary along the circumference. The computation of the local stress distribution in a partially or fully tethered vessel and the detailed relation of the stress to the remodeling pattern remains a task for future investigations.

Although we did not measure cardiac function in the present group of experimental animals, we did not observe any hemodynamic or electrophysiological changes in the hearts in response to a single ligation of the LAD vein. Previously, Gross et al. (7) have shown that prior venous ligation reduces the mortality rate from subsequent coronary ligation. This is consistent with the well-known clinical observation that patients with right heart failure, and hence elevated coronary sinus pressure, are less prone to anginal pain.

The venous ligation changes not only local blood pressure but also blood flow. Although it is very difficult to measure blood flow in the epicardial veins because they are easily collapsible, it is reasonable to expect that the flow is decreased, especially near the ligation where there may be flow stagnation. The degree of flow reduction depends on the presence of bifurcations near the ligation that allows venting of flow. The adaptation of vessel lumen to changes in flow is in line with the constant wall shear stress hypothesis (11, 16, 17). Ultimately, the pattern of remodeling will depend on the degree of changes in both pressure and flow. Bakker et al. (2) found that the rat cremaster arterioles developed inward remodeling at zero flow and physiological pressure, whereas they did not observe remodeling at low pressure (3).

It is well known that fixation and histological processing of tissues, such as dehydration, embedding, sectioning, and staining, can cause dimensional changes and tissue distortion. In the present study, we used a fixation and tissue processing procedure that was recently shown to produce minimal distortion (5). In coronary arteries, it was found that the differences in dimensions between the histological sections and the fresh tissues to be within ~10% (5). The difference between the sham-operated and experimental tissue should be unaffected, however, because the same procedure was used in both groups.

In summary, the present study systematically characterizes the structural remodeling of the LAD vein at an intermediate pressure (between arterial and venous values). Our data show that the remodeling is nonuniform circumferentially and axially. This nonuniformity stems from the nonuniformity of the intramural stress field, which is dictated by the degree of radial myocardial constraint. In the venous vessels that are completely surrounded by the myocardium, the remodeling is circumferentially uniform as is the increase in wall thickness. The venous vessel is transformed from a thin-walled, large lumen vessel to a thicker-walled, smaller lumen vessel as depicted in Fig. 12. Future studies are needed where the prearterialized LAD veins are exposed to arterial pressure and flow, such as during coronary retroperfusion. With such studies we would expect further arterializations of the venous system in response to elevated pressure and expansive enlargement of the vessel lumens due to increased flow. Such observations and considerations are important for designing a therapeutic rationale for the nourishment of ischemic myocardium through venous retroperfusion.


Figure 12
View larger version (30K):
[in this window]
[in a new window]
 
Fig. 12. Schematic representation of cross-section of proximal ring in experimental and sham-operated control groups.

 

    GRANTS
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 
This research was supported in part by the National Heart, Lung, and Blood Institute Grant 2-R01-HL-055554–06, the American Heart Association Grant-in-Aid 0555058Y, and TransVascular, Inc. (Menlo Park, CA).


    ACKNOWLEDGMENTS
 
We thank Carlos Linares and Hans Mooij for excellent technical assistance.


    FOOTNOTES
 

Address for reprint requests and other correspondence: G. S. Kassab, Dept. of Biomedical Engineering, Univ. of California, Irvine, 204 Rockwell Engineering Ctr., Irvine, CA 92697-2715 (e-mail: gkassab{at}uci.edu)

The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.


    REFERENCES
 TOP
 ABSTRACT
 METHODS
 RESULTS
 DISCUSSION
 GRANTS
 REFERENCES
 

  1. Bakker EN, Buus CL, Spaan J, Perree J, Ganga A, Rolf TM, Sorop O, Bramsen LH, Mulvany MJ, and VanBavel E. Small artery remodeling depends on tissue-type transglutaminase. Circ Res 96: 119–126, 2005.[Abstract/Free Full Text]
  2. Bakker EN, van der Meulen ET, van den Berg BM, Everts V, Spaan JA, and VanBavel E. Inward remodeling follows chronic vasoconstriction in isolated resistance arteries. J Vasc Res 39: 12–20, 2002.[CrossRef][ISI][Medline]
  3. Bakker EN, Versluis JP, Sipkema P, VanTeeffelen JW, Rolf TM, Spaan JA, and VanBavel E. Differential structural adaptation to haemodynamics along single rat cremaster arterioles. J Physiol 548: 549–555, 2003.[Abstract/Free Full Text]
  4. Chiu CJ and Mulder DS. Selective arterialization of coronary veins for diffuse coronary occlusion. J Thorac Cardiovasc Surg 70: 177–182, 1975.[Abstract]
  5. Choy JS, Mathieu-Costello O, and Kassab GS. The effect of fixation and histological preparation on coronary artery dimensions. Ann Biomed Eng 33: 1027–1033, 2005.[CrossRef][ISI][Medline]
  6. Dethlefsen SM, Shepro D, and D'Amore PA. Comparison of the effects of mechanical stimulation on venous and arterial smooth muscle cells in vitro. J Vasc Res 33: 405–413, 1996.[ISI][Medline]
  7. Gross L, Blum L, and Silverman G. Experimental attempts to increase the blood supply to the dog's heart by means of coronary sinus occlusion. J Exp Med 65: 91–108, 1937.[Abstract]
  8. Hamza L, Dang Q, Lu X, Mian A, Molloi S, and Kassab GS. Effect of passive myocardium on the compliance of the coronary arteries. Am J Physiol Heart Circ Physiol 285: H653–H660, 2003.[Abstract/Free Full Text]
  9. Hayashi K, Mori K, and Miyazaki H. Biomechanical response of femoral vein to chronic elevation of blood pressure in rabbit. Am J Physiol Heart Circ Physiol 284: H511–H518, 2003.[Abstract/Free Full Text]
  10. Hughes GC, Post MJ, Simons M, and Annex BH. Porcine models of human coronary artery disease: implications for preclinical trials of therapeutic angiogenesis. J Appl Physiol 94: 1689–1701, 2003.[Abstract/Free Full Text]
  11. Kamiya A and Togawa T. Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol Heart Circ Physiol 239: H14–H21, 1980.[Abstract/Free Full Text]
  12. Kassab GS and Fung YC. The pattern of coronary arteriolar bifurcations and the uniform shear hypothesis. Ann Biomed Eng 23: 13–20, 1995.[CrossRef][ISI][Medline]
  13. Kassab GS, Gregersen H, Nielsen SL, Lu X, Tanko L, and Falk E. Remodeling of the coronary arteries in supra-valvular aortic stenosis. J Hypertens 20: 2429–2437, 2002.[CrossRef][ISI][Medline]
  14. Kassab GS, Lin DH, and Fung YC. Morphometry of pig coronary venous system. Am J Physiol Heart Circ Physiol 267: H2100–H2112, 1994.[Abstract/Free Full Text]
  15. Langille BL and Dajnowiec D. Cross-linking vasomotor tone and vascular remodeling: a novel function for tissue transglutaminase? Circ Res 96: 9–11, 2005.[Free Full Text]
  16. Langille BL and O'Donnel F. Reductions in arterial diameter produced by chronic disease in blood flow are endothelium-dependent. Science 231: 405–407, 1986.[Abstract/Free Full Text]
  17. Lu X, Zhao JB, Wang GR, Gregersen H, and Kassab GS. Remodeling of the zero-stress state of the femoral artery in response to flow-overload. Am J Physiol Heart Circ Physiol 280: H1547–H1559, 2001.[Abstract/Free Full Text]
  18. Marco JD, Hahn JW, Barner HB, Jellinek M, Blair OM, Standeven JW, and Kaiser GC. Coronary venous arterialization: acute hemodynamic, metabolic, and chronic anatomical observations. Ann Thorac Surg 23: 449–454, 1977.[Abstract]
  19. Matsumoto T and Hayashi K. Mechanical and dimensional adaptation of rat aorta to hypertension. J Biomech Eng 116: 278–283, 1994.[ISI][Medline]
  20. Moll JW, Dziatkowiak AJ, Edelman M, Iljin W, Ratajczyk-Pakalska E, and Stengert K. Arterialization of the coronary veins in diffuse coronary arteriosclerosis. J Card Surg 16: 520–525, 1975.
  21. Oh BH, Volpini M, Kambayashi M, Murata K, Rockman HA, Kassab GS, and Ross J Jr. Myocardial function and transmural blood flow during coronary venous retroperfusion in pigs. Circulation 86: 1265–1279, 1992.[Abstract/Free Full Text]
  22. Scharf SM, Bromberger-Barnea B, and Permutt S. Distribution of coronary venous flow. J Appl Physiol 30: 657–662, 1971.[Free Full Text]
  23. Vaishnav RN, Vossoughi J, Patel DJ, Cothran LN, Coleman BR, and Ison-Franklin EL. Effect of hypertension on elasticity and geometry of aortic tissue from dogs. J Biomech Eng 112: 70–74, 1990.[ISI][Medline]
  24. Wolinsky H. Effects of hypertension and its reversal on the thoracic aorta of male and female rats. Circ Res 28: 622–637, 1971.[Abstract/Free Full Text]
  25. Wolinsky H. Long-term effects of hypertension on the rat aortic wall and their relation to concurrent againg changes. Circ Res 30: 301–309, 1972.[Abstract/Free Full Text]
  26. Zajtchuk R, Heydorn WH, and Miller JG. Revasculation of the heart through the coronary vein. Ann Thorac Surg 21: 318–321, 1976.[Abstract]
  27. Zhang W, Herrera C, Atluri SN, and Kassab GS. Effect of surrounding tissue on vessel fluid and solid mechanics. J Biomech Eng 126: 760–769, 2004.[CrossRef][ISI][Medline]
  28. Zhang W, Herrera C, Atluri SN, and Kassab GS. The effect of longitudinal pre-stretch and radial constraint on the stress distribution in the vessel wall: a new hypothesis. Mech Chem Biosystems 2: 41–52, 2005.



This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
G. S. Kassab, J. A. Navia, K. March, and J. S. Choy
Coronary venous retroperfusion: an old concept, a new approach
J Appl Physiol, May 1, 2008; 104(5): 1266 - 1272.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Y. Liu, W. Zhang, and G. S. Kassab
Effects of myocardial constraint on the passive mechanical behaviors of the coronary vessel wall
Am J Physiol Heart Circ Physiol, January 1, 2008; 294(1): H514 - H523.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
Y. Liu, C. Dang, M. Garcia, H. Gregersen, and G. S. Kassab
Surrounding tissues affect the passive mechanics of the vessel wall: theory and experiment
Am J Physiol Heart Circ Physiol, December 1, 2007; 293(6): H3290 - H3300.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
S. W. Watts, C. Rondelli, K. Thakali, X. Li, B. Uhal, M. H. Pervaiz, R. E. Watson, and G. D. Fink
Morphological and biochemical characterization of remodeling in aorta and vena cava of DOCA-salt hypertensive rats
Am J Physiol Heart Circ Physiol, May 1, 2007; 292(5): H2438 - H2448.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
J. S. Choy and G. S. Kassab
A novel strategy for increasing wall thickness of coronary venules prior to retroperfusion
Am J Physiol Heart Circ Physiol, August 1, 2006; 291(2): H972 - H978.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
290/4/H1558    most recent
00928.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Choy, J. S.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Choy, J. S.
Right arrow Articles by Kassab, G. S.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.