1Department of Physiology and Pharmacology, Section for Anaesthesiology and Intensive Care, Karolinska Institute, Stockholm, Sweden; and 2Perioperative and Surgical Sciences, Anesthesiology and Intensive Care Medicine, Umeå University, Umeå, Sweden
Submitted 19 September 2006 ; accepted in final form 30 March 2007
| ABSTRACT |
|---|
|
|
|---|
sepsis; endotoxin; inotropy; end-systolic elastance; diastolic
In the heart, the predominant ET isopeptide is ET-1 (47), and both ETA and ETB receptors are found in the myocardium, endocardium, conducting system, and coronary vessels (4, 39). The ET system and ET-1 binding properties on cardiomyocytes are largely similar in pigs and humans (38).
The ET system is involved in the cardiovascular response to several disease processes. Increased plasma levels of ET-1 have been noted in association with acute myocardial infarction, congestive heart failure, pulmonary hypertension, and septic shock (59). In human sepsis, ET-1 plasma levels are increased fivefold (61) and correlates to severity of illness, as well as outcome (7). Previous reports, including those from our own group, have shown positive cardiovascular effects using ET-receptor antagonists in septic settings (10, 29, 43, 56). However, none of these studies was designed to evaluate specific cardiac effects, and the positive results seen may merely constitute alterations in cardiac pre- or afterload. Interestingly, other investigators have reported conflicting inotropic effects of ET-1 in normal vs. pathological conditions (33, 53). By analogy, we were recently able to demonstrate positive inotropic effects of intracoronary administration of ET-1 in normal, anesthetized pigs (30).
The aim of the present study was to investigate the cardiac effects of ET-receptor antagonism in endotoxemic pigs. Left ventricular (LV) pressure-volume relations (LVPVR) were examined by means of conductance volumetry in an in vivo model of porcine endotoxemia. On the basis of our previous results, we postulated that dual ET-1 receptor antagonism by administration of tezosentan would improve myocardial contractile and diastolic function in a septic state.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Sixteen female domestic land race pigs weighing between 38 and 55 kg were anesthetized after fasting overnight with free access to water. After intramuscular injections of ketamine 10 mg/kg, azaperone 4 mg/kg, and atropine 50 µg/kg, anesthesia was induced with pentobarbital sodium 12 mg/kg iv and maintained by a continuous infusion of pentobarbital sodium 5 mg·kg–1·h–1, midazolam 0.3 mg·kg–1·h–1 and fentanyl 20 µg·kg–1·h–1. Intravenous fluids were administered as Ringer acetate at a rate of 20 ml·kg–1·h–1 throughout the study period. After tracheotomy, the animals were mechanically ventilated (Evita 4 ventilator; Draeger Medical, Lubeck, Germany) with an FIO2 of 0.4, peak end-expiratory pressure of 5 cmH2O (Artema; Artema Medical, Stockholm, Sweden) with tidal volumes less than 10 ml/kg. If arterial oxygen tension (PaO2) dropped below 6.5 kPa, FIO2 was increased with increments of 0.10. Blood gas measurements were performed hourly (ABL 5, Radiometer, Copenhagen, Denmark). Body temperature was measured and maintained between 38° and 39°C with the help of heating pads and a warming blanket.
All vascular catheters were placed through direct cutdowns onto the jugular or carotid vessels. A three-lumen central venous catheter (Arrow International, Reading, PA) and a thermistor-tipped pulmonary artery catheter (Optimetrix, Abbott, IL) were placed. An arterial catheter was placed with the tip in the descending aorta. A 7.5 French (Fr) balloon occlusion catheter (Vascular Technologies, Solna, Sweden) was positioned in the inferior vena cava directly adjacent to the right atrium to provide a controlled transient restriction of venous return. Arterial, central venous, and pulmonary artery pressures were measured using a fluid-filled catheter system and transducers (Gabarith PMSET, Becton Dickinson, Franklin Lakes, NJ). A 7 Fr left ventricular (LV) pigtail combination tip manometer and conductance catheter (CA-71083-PN; CD Leycom, Zoetermeer, Holland) was placed through an 8.5 Fr introducer in the carotid artery system into the left ventricle using fluoroscopic guidance. A dual thermistor-tipped coronary sinus catheter (Webster, CA) was placed in the great cardiac vein. Catheter position was checked and rechecked using fluoroscopy, and minimal amounts of intravascular radiographic contrast (Visipaque; Amersham, Solna, Sweden). An intravenous heparin infusion, 1,000 IE per hour, was started when the cardiac catheters were in place to minimize the risk of catheter-related thrombosis. At termination of the experiment, the pigs were euthanized using a combination of pentobarbital sodium bolus intravenously followed by a bolus of potassium intravenously.
Measurements and calculations. The conductance volumetry technique is well described elsewhere (52) and we have previously described this method in depth (8, 21). LV volume was measured using the 12-electrode dual-field conductance catheter with 8-mm spacing between electrodes, and a signal conditioning-amplifier (Leycom Sigma 5DF, Cardiodynamics, Zoetermeer, Holland). The volume signal was calibrated using a stroke volume and flow reference ratio derived from thermodilution cardiac output measurements obtained using the pulmonary artery catheter and a thermodilution computer (Wetenskappelijk Technische Instituut, Rotterdam, Holland). Parallel conductance for LV volume signal was measured using the hypertonic saline method (51). Left ventricular pressure and conductance data were recorded with a sampling rate of 250 Hz using a software package (PC Conduct, Cardiodynamics). All circulatory measurements were recorded and analyzed using a digital signal acquisition and analysis software package (Acqknowledge, Biopac Systems, Santa Barbara, CA).
Great cardiac vein flow (QGCV) was measured by thermodilution. Coronary oxygen (O2) kinetics were calculated as follows: arterial O2 content = [(arterial partial pressure O2 x 0.23) + [hemoglobin concentration](1.39 x arterial O2 saturation)]; great cardiac vein (GCV) O2 content = {(GCV partial pressure O2 x 0.23) + [hemoglobin concentration] [1.39 x GCV O2 saturation (SGCVO2)]}; myocardial O2 delivery (MDO2) = QGCV x arterial O2 content; myocardial O2 consumption (M
O2) = (arterial O2 content – GCV O2 content) x QGCV; and myocardial O2 extraction ratio (MOER) = 100 x M
O2/DO2. The units used for O2 content is milliliters per liter and for partial pressure in kilopascals.
General hemodynamic parameters for each point in the protocol were measured: heart rate (HR), mean arterial blood pressure (MAP), cardiac output, stroke volume (SV), central venous pressure (CVP), mean pulmonary artery pressure (MPAP), LV end-systolic volume, LV end-diastolic volume (LVEDV), LV end-systolic pressure, LV end-diastolic pressure, LV maximal rate of change in pressure (dP/dtmax), and maximum negative rate of pressure change (dP/dtmin). End diastole was identified as the maximum LV volume before isovolumic pressure increase, which was timed for the purpose of analysis of sequences with multiple heart cycles to 8–16 ms before measured dP/dtmax or 8–16 ms after the intracardiac ECG R wave. LV stroke work (SW) was measured from the integral of the pressure-volume area for each heart cycle. Power max (Powermax) was calculated for each beat as the maximal instantaneous pressure-flow product during systole (41). The analysis of contractile parameters was made from a selection of contiguous beats within physiological pressure ranges and also based on strong linearity in the end-systolic pressure-volume (P/V) relation. The end-systolic points were initially estimated as maximal pressure/volume for each cycle, and these beats were used to establish an end-systolic pressure-volume relation (ESPVR) for all beats, with an x-intercept. A tangent to this x-intercept was then used to find a new end-systolic P/V point for all beats, and a final ESPVR (24). Total potential energy (PVA) was calculated for a single resting beat at the onset of a preload reduction sequence using the ESPVR and then (0.5)Pes(Ves – Vo), where Pes was LV end-systolic pressure, Ves was LV end-systolic volume, and Vo was the LV volume at the x-intercept for the ESPVR. SW was calculated for the same beat, and myocardial efficiency was expressed as SW/PVA. For diastolic parameters, tau is the time constant for pressure decay during the isovolumic relaxation phase assuming a nonzero asymptote (9). Additionally, the half-time for pressure decay during isovolumic relaxation (t1/2) was measured (37). Also, for each measurement point in the protocol, a controlled preload alteration was performed during a brief period of apnea using transient inflation of the balloon-tipped catheter to occlude the inferior vena cava for a short period (6–8 s). A sequence of 6–12 contiguous heart cycles was later selected from this sequence for analysis, based on a progressive beat-to-beat reduction in end-diastolic and end-systolic LV volumes. This sequence was analyzed for end-systolic elastance (Ees) (24) and preload recruitable stroke work (PRSW) (18). All myocardial function parameters were calculated using custom software.
Biochemical analyses. Plasma levels of ET-1-like immunoreactivity (ET-1 LI) were analyzed with radioimmunoassay, as described by Hemsén (22). Troponin I in plasma was analyzed by a two-position immunoenzymatic assay (Beckman Coulter, Fullerton, CA).
Experimental protocol. Upon completion of the preparation, a 45-min stabilization period was allowed. After baseline measurements, an intravenous infusion of endotoxin (Escherichia coli B0111:B4; Sigma, St. Louis, MO) was started in all animals beginning at 0.05 µg·kg–1·h–1 and gradually increased to reach 0.25 µg·kg–1·h–1 within 45 min. After 3 h, eight animals received a short infusion of tezosentan (1 mg/kg in 10 min) followed by a continuous infusion of tezosentan at 1 mg·kg–1·h–1. General hemodynamics, blood gases, and cardiac function were assessed every hour, and plasma samples for analyses of ET-1 LI and troponin I were drawn at baseline, after 3 and 5 h.
Statistical analysis. Data are presented as means ± SE. A univariate repeated-measures ANOVA was used for analyzing changes over time from baseline until 3 h for evaluating effects of endotoxin administration and for differences between groups before intervention. A repeated-measures ANOVA using the time point 3 h as a covariate was used for evaluating effects of tezosentan administration from 4 to 5 h. Regarding ET-1 LI and troponin I, differences between groups postintervention were evaluated by ANOVA with analysis of the time-treatment interaction. Differences were considered significant at P < 0.05. A computer software program (STATISTICA 7.0 StatSoft, Tulsa, OK) was utilized for statistical calculations.
| RESULTS |
|---|
|
|
|---|
|
|
|
|
|
O2 were not affected by endotoxin, but there were significant differences between groups before intervention. MDO2 was slightly decreased in response to tezosentan. MOER was slightly increased in the tezosentan group compared with controls. Biochemical parameters. Endotoxemia caused a twofold increase in plasma ET-1 LI immunoreactivity. Tezosentan further increased ET-1 LI and resulted in a fourfold increase compared with controls at 5 h. Troponin levels were elevated in response to endotoxin by 57%. Tezosentan did not influence this parameter (Fig. 4).
|
| DISCUSSION |
|---|
|
|
|---|
Endotoxemia per se was not associated with detectable changes in myocardial contractile function in the present study. Similar in vivo findings have been described by others (3, 46), whereas some authors have reported increased (12, 23) or decreased (1, 32, 62) contractile function in early endotoxemia. The abovementioned investigators have all used load-independent measures of contractility and endotoxin, although in different doses and serotypes and in various species. Therein lies possibly the explanation for the diverging reports. The manner by which endotoxin is infused is also important, where a continuous infusion of endotoxin is preferable to bolus infusions as a model of human sepsis because it generally produces a more persistent pathophysiological response (20). Our current results suggest that endotoxin did not cause detectable LV contractile impairment, but sympathetic activation in response to endotoxin may very well have compensated for a negative inotropic effect of endotoxin, as suggested by Smith et al. (12, 50). The increase in HR seen following endotoxemia would support this concept but when blocking baroreceptor reflexes, Aghajani et al. (2) still could not see evidence of impaired contractility in endotoxemic pigs. Intriguingly, Ishihara et al. (23) reported biphasic, time-dependent changes in LV systolic performance in awake pigs receiving continuous infusion of endotoxin for 24 h. They reported an initial increase in Ees in the first hours followed by a significant sustained decrease in Ees after 7 h and onward. Studies in humans of myocardial depression are invariably not done within the first few hours of sepsis debut, but investigators often find depressed systolic function upon presentation in the intensive care unit and days thereafter (48). Our findings, within the limited time frame under which they are conducted, do not rule out the possibility that ET-1 may play a significant role in the clinical presentation of depressed systolic function at a later stage of sepsis as well. Interestingly, ET plasma levels have been shown to remain elevated in up to 28 days after onset of severe sepsis (55).
Although many studies performed in vitro in various species show conflicting results regarding myocardial effects of ET-1 (49, 65), there are several reports done in larger animals and humans that seem to indicate positive inotropic effects of ET-1 under nondisease conditions (33, 60). We recently reported that exogenous ET-1 administered into the coronary circulation had positive, dose-related effects on LV systolic performance in a nonseptic setting (30).
Interestingly, in pathological states, such as congestive heart failure, ET receptor antagonism has shown positive effects in some clinical trials (54) but with increasing doses, the overall effect may be negative. Similarly, there are reports on ET-1 exerting negative inotropic effects during pathological conditions such as congestive heart failure (33, 53).
Despite an improved CI, tezosentan administration was associated with impairment of LV contractile status. In our previous studies, we have shown beneficial effects on CI, SV, SW, and survival using dual ET receptor antagonists (29, 58). However, load-independent measures of LV contractile performance were not used in those studies. The positive effects seen may well have been due to reductions in afterload. In the present study, we therefore utilized LVPVR to minimize loading confounders, a method previously validated by others (52). Sepsis and endotoxemia are associated with marked alterations in both pre- and afterload, making the choice of method crucial for analyzing myocardial effects in vivo.
In the current paper Ees, PWRmax/LVEDV, and dP/dtmax/LVEDV all decreased in response to tezosentan, and there was a tendency for PRSW to move in the same direction. Because all of these load-independent parameters show congruent results, the conclusion that tezosentan had negative inotropic effects in this setting is fair. This is also in agreement with our recent study in which intracoronary ET-1 administration was associated with increased myocardial contractile function in "nonseptic" pigs (30), an effect likely mediated by ETA receptors. The inotropic effect of ETA-receptor activation has previously been described (25, 33), and this activation is thought to lead to increased sensitivity of the myofilaments for Ca2+ via the Na+/H+ exchanger, thus increasing cytoplasmic pH, increase in the inward Ca2+ current during depolarization and posttranslational modification of myofibrillar proteins (63). Few investigators have proposed the ETB receptor as primarily responsible for the inotropic effects of ET-1 (5). Our current data implicate that the increase in ET-1 levels seen in endotoxemia may provide a response to uphold LV contractile function.
The effects of endotoxemia on general hemodynamics were primarily hypodynamic, and pulmonary hypertension was prominent. Gas exchange was impaired, seen as decrease in PaO2 and increase in PaCO2. Tezosentan administration was associated with increases in CI and stroke volume index, as well as decreases in SVRI, MPAP, PVRI, and CVP, whereas MAP was further decreased and HR was unaffected. The beneficial findings on global hemodynamics are possibly related to the vasodilatory effects of dual ET-receptor antagonism, more pronounced in a state of sepsis in which the ET system is markedly activated (fourfold increase in plasma ET-1 LI levels) than in a state of nonseptic anesthetized pigs (35).
Mechanical efficiency (SW/PVA) was also studied, and there was a modest decrease in response to endotoxin before intervention. In another pig model of endotoxemia, mechanical efficiency was also impaired (3), and similar findings have been shown in septic models in rats (26) and dogs (28). Contrarily, Constable et al. (12) demonstrated increased SW/PVA in endotoxemic neonatal calves. SW/PVA is most reliable as a measure of in vivo mechanical efficiency if ventricular load and heart rate are maintained relatively constant during serial mechanical efficiency measures. These were not experimentally controlled in this model.
In the literature, there is some evidence that ET-1 improves contractile efficiency in vitro (63, and references therein). This means that antagonizing the ET system would impair myocardial efficiency but, in the current study, tezosentan administration was not associated with further effects on SW/PVA.
Endotoxemia was associated with deterioration of isovolumic relaxation, seen as prolongation of tau, but had no evident effects on LV stiffness. Several investigators have reported similar findings (1, 62). In healthy volunteers, Kiely et al. (27) infused ET-1 intravenously and found impaired LV relaxation using echocardiographic parameters. In a cecal inoculation model in rats, Brahmbhatt and coworkers (6) could show prolongation of tau at 12 and 24 h postinoculation, which was further prolonged by infusing BigET-1, a precursor of ET-1. This suggests that sepsis per se as well as the ET system impairs LV isovolumic relaxation. Diastolic dysfunction is also seen in septic patients either as a sole manifestation of septic myocardial depression or in conjunction with systolic dysfunction (48).
Tezosentan improved isovolumic relaxation (tau and t
) and decreased LV stiffness. These findings are in line with our previous work (29) in which high-volume resuscitated endotoxemic pigs improved measures of LV stiffness when treated with tezosentan in the same dosage. In a recent study from our group, we administered either ET-1 or sarafotoxin 6c, a selective ETB-receptor agonist, into the coronary circulation (30). Both of these peptides were associated with deteriorated isovolumic relaxation (tau and t1/2) which suggest that the ETB- receptor is strongly involved. ET receptor antagonism has also been beneficial in this regard in other models. Goldberg et al. (19) reported impairment in human myocyte relaxation upon ET-1 administration, which was attenuated by an ETA-receptor antagonist, and Mebazaa et al. (34) reported that papillary muscles from rabbits exposed to endotoxin in vivo could show prolonged time to half relaxation, which was counteracted by an ETA-receptor antagonist. These authors found the ETA-receptor responsible for the negative lusitropic effects, whereas our previous results strongly suggest the ETB-receptor (30). The present data do not discriminate which of the ET receptors are responsible for the effects seen. However, while being a dual ET receptor antagonist, tezosentan has a high ETA/ETB antagonizing effect ratio (11). Therefore, a high degree of ETA-receptor antagonism would be expected in this model, suggesting that the results possibly were mainly due to ETA-receptor antagonism. On the other hand, there is clear evidence of ETB-receptor antagonizing effects by tezosentan seen as increased levels of plasma ET-1 LI. The elevation of plasma ET-1 upon ET receptor antagonism depends upon blocking pulmonary endothelial ETB-receptors, which are responsible for the clearing function of circulating ET-1 (16).
These results suggest that specific ETB receptor antagonism could be preferable, improving diastolic function without negatively affecting systole. However, in a previous study from our group, selective ETB-receptor antagonism proved detrimental during endotoxemia, probably due to unopposed vasoconstriction mediated by ETA receptors and decreased ET clearance (57).
Endotoxemia was not associated with any effects on cardiac oxygen utilization parameters or QGCV. MOER decreased somewhat in response to endotoxin, an effect also seen in human sepsis (14). As previously reported in both human sepsis and animal endotoxemia (29) cardiac troponin I was increased in response to endotoxin. The mechanisms behind this phenomenon are yet unclear, but mere ischemia is unlikely since neither in this model nor in human sepsis is myocardial hypoperfusion evident (14). Tezosentan administration was coupled to a modest decrease in MDO2, possibly related to the concomitant decrease in hemoglobin, and a modest increase in MOER. These effects were quite small and are less likely to have had an impact on the results of cardiac function. Interestingly, a recent report from Merkus et al. (36) suggests a local regulating factor responsible for abolished ET-1-mediated constrictor effect on coronary resistance vessels. Cardiac troponin I was not affected by tezosentan.
In conclusion, in this porcine model of early endotoxemia dual ET receptor antagonism with tezosentan was associated with a reduction in contractile function, despite improved global hemodynamic parameters. In contrast, ET receptor antagonism seemed to improve diastolic function. Positive hemodynamic effects from ET receptor antagonism in acute endotoxemia may be due to changes in cardiac load and enhanced diastolic function rather than improved contractile function.
| GRANTS |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
The costs of publication of this article were defrayed in part by the payment of page charges. The article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. J. Lester, A. J. Tajik, R. A. Nishimura, J. K. Oh, B. K. Khandheria, and J. B. Seward Unlocking the Mysteries of Diastolic Function Deciphering the Rosetta Stone 10 Years Later. J. Am. Coll. Cardiol., February 19, 2008; 51(7): 679 - 689. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |