|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1 Medicine/Cardiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
* To whom correspondence should be addressed. E-mail: hsilber{at}jhmi.edu.
Flow mediated dilation (FMD) is strongly dependent on arterial size, but the reasons for this phenomenon are poorly understood. We have previously shown that FMD is greater in small brachial arteries because the shear stress stimulus is greater in small brachial arteries. However, it is unclear why the shear stimulus is greater in small arteries. Furthermore, this relationship has not been investigated in other, differently sized arterial beds. Post-ischemic systolic shear stress and resulting FMD were evaluated in the brachial and femoral arteries of 24 young, healthy adults using phase contrast magnetic resonance imaging (PCMRI). Arterial shear and radius were calculated from the velocity profile via a best-fit parabola, before and after occlusion. Summing the velocity pixels provided hyperemic systolic flow. FMD was proportional to hyperemic shear in the brachial and femoral arteries (p<.0001, r=.60). Hyperemic systolic flow was proportional to radius2 (p<.0001, r=.93). Applying this relationship to the Poiseuille equation (shear is proportional to flow/radius3) shows that hyperemic shear is proportional to radius2/radius3 and therefore explains why hyperemic shear is proportional to 1/radius. We conclude that FMD is proportional to hyperemic systolic shear stress in both the brachial and the femoral arteries. The hyperemic shear stimulus for FMD is greater in small arteries due to the dependence of post-ischemic systolic flow on radius squared. Therefore greater FMD in small arteries does not necessarily reflect better conduit artery endothelial function. Evaluating the shear stimulus using PCMRI enhances the understanding of mechanisms underlying flow mediated dilation.
This article has been cited by other articles:
![]() |
D. H. J. Thijssen, E. A. Dawson, M. A. Black, M. T. E. Hopman, N. T. Cable, and D. J. Green Heterogeneity in conduit artery function in humans: impact of arterial size Am J Physiol Heart Circ Physiol, November 1, 2008; 295(5): H1927 - H1934. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. A. Silber, J. A.C. Lima, D. A. Bluemke, B. C. Astor, S. N. Gupta, T. K. Foo, and P. Ouyang Arterial Reactivity in Lower Extremities Is Progressively Reduced as Cardiovascular Risk Factors Increase: Comparison With Upper Extremities Using Magnetic Resonance Imaging J. Am. Coll. Cardiol., March 6, 2007; 49(9): 939 - 945. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Wright, F. M. O'Prey, D. J. Rea, R. D. Plumb, A. J. Gamble, W. J. Leahey, A. B. Devine, R. C. McGivern, D. G. Johnston, M. B. Finch, et al. Microcirculatory Hemodynamics and Endothelial Dysfunction in Systemic Lupus Erythematosus Arterioscler. Thromb. Vasc. Biol., October 1, 2006; 26(10): 2281 - 2287. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Petersen, F. Wiesmann, L. E. Hudsmith, M. D. Robson, J. M. Francis, J. B. Selvanayagam, S. Neubauer, and K. M. Channon Functional and Structural Vascular Remodeling in Elite Rowers Assessed by Cardiovascular Magnetic Resonance J. Am. Coll. Cardiol., August 15, 2006; 48(4): 790 - 797. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |
| Visit Other APS Journals Online |