AJP - Heart Journal of Neurophysiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol (February 21, 2003). doi:10.1152/ajpheart.00721.2002
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
284/6/H2288    most recent
00721.2002v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Makale, M. T.
Right arrow Articles by Gough, D. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Makale, M. T.
Right arrow Articles by Gough, D. A.
Submitted on August 21, 2002
Accepted on February 6, 2003

Tissue Window Chamber System for Validation of Implanted Oxygen Sensors

Milan T. Makale1, Joe T. Lin1, Richard E. Calou1, Amy G. Tsai1, Peter C. Chen1, and David A. Gough1*

1 Department of Bioengineering, University of California San Diego, La Jolla, CA, USA

* To whom correspondence should be addressed. E-mail: dgough{at}bioeng.ucsd.edu.

An experimental system is described for validating electrochemical oxygen sensors implanted in tissues. The system is a modified hamster window chamber in which a thin layer of vascularized tissue is held between two plates, one having an observation window and the other an array of oxygen sensors. This arrangement permits simultaneous recording of oxygen sensor signals and non-destructive visualization of the tissue adjacent to the sensors over periods of one month or more, without the inhibitory effects of anesthesia. The system provides a means for study of the effects of spatial and temporal oxygen distributions on the sensor signals and adaptation of the tissue structure over time. Examples are given of sensor recordings and images of tissues with implanted oxygen sensor arrays.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. T. Makale, P. C. Chen, and D. A. Gough
Variants of the tissue-sensor array window chamber
Am J Physiol Heart Circ Physiol, July 1, 2005; 289(1): H57 - H65.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
Visit Other APS Journals Online
Copyright © 1976 by the American Physiological Society.