AJP - Heart Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol (December 14, 2007). doi:10.1152/ajpheart.01082.2007
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
294/2/H909    most recent
01082.2007v2
01082.2007v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olgac, U.
Right arrow Articles by Poulikakos, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olgac, U.
Right arrow Articles by Poulikakos, D.
Submitted on September 18, 2007
Accepted on December 7, 2007

COMPUTATIONAL MODELING OF COUPLED BLOOD-WALL MASS TRANSPORT OF LDL: EFFECTS OF LOCAL WALL SHEAR STRESS

Ufuk Olgac1, Vartan Kurtcuoglu2, and Dimos Poulikakos2*

1 Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
2 Zurich, Switzerland; Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland

* To whom correspondence should be addressed. E-mail: dimos.poulikakos{at}ethz.ch.

The work herein represents a novel approach for the modeling of low-density lipoprotein (LDL) transport from the artery lumen into the arterial wall, taking into account the effects of local wall shear stress (WSS) on the endothelial cell layer and its pathways of volume and solute flux. We have simulated LDL transport in an axisymmetric representation of a stenosed coronary artery, where the endothelium is represented by a three-pore model that takes into account the contributions of the vesicular pathway, normal junctions and leaky junctions also employing the local WSS to yield the overall volume and solute flux. The fraction of leaky junctions is calculated as a function of the local WSS based on published experimental data and is used in conjunction with the pore-theory to determine the transport properties of this pathway. We have found elevated levels of solute flux at low shear stress regions due to the presence of a larger number of leaky junctions compared to high shear stress regions. Accordingly, we were able to observe high LDL concentrations in the arterial wall in these low shear stress regions despite increased filtration velocity, indicating that the increase in filtration velocity is not sufficient for the convective removal of LDL.




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Dabagh, P. Jalali, and J. M. Tarbell
The transport of LDL across the deformable arterial wall: the effect of endothelial cell turnover and intimal deformation under hypertension
Am J Physiol Heart Circ Physiol, September 1, 2009; 297(3): H983 - H996.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
U. Olgac, D. Poulikakos, S. C. Saur, H. Alkadhi, and V. Kurtcuoglu
Patient-specific three-dimensional simulation of LDL accumulation in a human left coronary artery in its healthy and atherosclerotic states
Am J Physiol Heart Circ Physiol, June 1, 2009; 296(6): H1969 - H1982.
[Abstract] [Full Text] [PDF]