|
|
||||||||
1Clinical Research Institute of Montreal, Montreal, Quebec, Canada; 2Department of Cardiothoracic Surgery, Academic Hospital, Maastricht, The Netherlands; and 3Quebec Heart Institute, Laval Hospital, Laval University, Quebec, Canada
Submitted 27 July 2004 ; accepted in final form 8 December 2004
In patients with aortic stenosis, the left ventricular afterload is determined by the degree of valvular obstruction and the systemic arterial system. We developed an explicit mathematical model formulated with a limited number of independent parameters that describes the interaction among the left ventricle, an aortic stenosis, and the arterial system. This ventricular-valvular-vascular (V3) model consists of the combination of the time-varying elastance model for the left ventricle, the instantaneous transvalvular pressure-flow relationship for the aortic valve, and the three-element windkessel representation of the vascular system. The objective of this study was to validate the V3 model by using pressure-volume loop data obtained in six patients with severe aortic stenosis before and after aortic valve replacement. There was very good agreement between the estimated and the measured left ventricular and aortic pressure waveforms. The total relative error between estimated and measured pressures was on average (standard deviation) 7.5% (SD 2.3) and the equation of the corresponding regression line was y = 0.99x 2.36 with a coefficient of determination r2 = 0.98. There was also very good agreement between estimated and measured stroke volumes (y = 1.03x + 2.2, r2 = 0.96, SEE = 2.8 ml). Hence, this mathematical V3 model can be used to describe the hemodynamic interaction among the left ventricle, the aortic valve, and the systemic arterial system.
mathematical modeling; cardiovascular system; cardiac catheterization; left ventricle
This article has been cited by other articles:
![]() |
W. K. Laskey, W. G. Kussmaul III, and A. Noordergraaf Systemic Arterial Response to Exercise in Patients With Aortic Valve Stenosis Circulation, February 24, 2009; 119(7): 996 - 1004. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Garcia, P. G. Camici, L.-G. Durand, K. Rajappan, E. Gaillard, O. E. Rimoldi, and P. Pibarot Impairment of coronary flow reserve in aortic stenosis J Appl Physiol, January 1, 2009; 106(1): 113 - 121. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Tanne, L. Kadem, R. Rieu, and P. Pibarot Hemodynamic impact of mitral prosthesis-patient mismatch on pulmonary hypertension: an in silico study J Appl Physiol, December 1, 2008; 105(6): 1916 - 1926. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| Visit Other APS Journals Online |