AJP - Heart pressure measurements
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 291: H184-H192, 2006. First published February 24, 2006; doi:10.1152/ajpheart.01300.2005
0363-6135/06 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
291/1/H184    most recent
01300.2005v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (16)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ripplinger, C. M.
Right arrow Articles by Efimov, I. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ripplinger, C. M.
Right arrow Articles by Efimov, I. R.

Mechanisms of unpinning and termination of ventricular tachycardia

Crystal M. Ripplinger, Valentin I. Krinsky, Vladimir P. Nikolski, and Igor R. Efimov

Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri

Submitted 8 December 2005 ; accepted in final form 8 February 2006

High-energy defibrillation shock is the only therapy for ventricular tachyarrhythmias. However, because of adverse side effects, lowering defibrillation energy is desirable. We investigated mechanisms of unpinning, destabilization, and termination of ventricular tachycardia (VT) by low-energy shocks in isolated rabbit right ventricular preparations (n = 22). Stable VT was initiated with burst pacing and was optically mapped. Monophasic "unpinning" shocks (10 ms) of different strengths were applied at various phases throughout the reentry cycle. In 8 of 22 preparations, antitachycardia pacing (ATP: 8–20 pulses, 50–105% of period, 0.8–10 mA) was also applied. Termination of reentry by ATP was achieved in only 5 of 8 preparations. Termination by unpinning occurred in all 22 preparations. Rayleigh's test showed a statistically significant unpinning phase window, during which reentry could be unpinned and subsequently terminated with E80 (magnitude at which 80% of reentries were unpinned) = 1.2 V/cm. All reentries were unpinned with field strengths ≤2.4 V/cm. Unpinning was achieved by inducing virtual electrode polarization and secondary sources of excitation at the core of reentry. Optical mapping revealed the mechanisms of phase-dependent unpinning of reentry. These results suggest that a 20-fold reduction in energy could be achieved compared with conventional high-energy defibrillation and that the unpinning method may be more effective than ATP for terminating stable, pinned reentry in this experimental model.

reentry; optical mapping; defibrillation; antitachycardia pacing



Address for reprint requests and other correspondence: I. R. Efimov, Campus Box 1097, One Brookings Dr., St. Louis, MO 63130 (e-mail: igor{at}wustl.edu)




This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. Agladze, M. W. Kay, V. Krinsky, and N. Sarvazyan
Interaction between spiral and paced waves in cardiac tissue
Am J Physiol Heart Circ Physiol, July 1, 2007; 293(1): H503 - H513.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.