AJP - Heart Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Am J Physiol Heart Circ Physiol 295: H482-H490, 2008. First published May 30, 2008; doi:10.1152/ajpheart.00223.2008
0363-6135/08 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
295/2/H482    most recent
00223.2008v2
00223.2008v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kolyva, C.
Right arrow Articles by Siebes, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kolyva, C.
Right arrow Articles by Siebes, M.

TRANSLATIONAL PHYSIOLOGY

Windkesselness of coronary arteries hampers assessment of human coronary wave speed by single-point technique

Christina Kolyva,1 Jos A. E. Spaan,1 Jan J. Piek,2 and Maria Siebes1,2

Departments of 1Medical Physics and 2Cardiology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands

Submitted 3 March 2008 ; accepted in final form 27 May 2008

A novel single-point technique to calculate local arterial wave speed (SPc) has recently been presented and applied in healthy human coronary arteries at baseline flow. We investigated its applicability for conditions commonly encountered in the catheterization laboratory. Intracoronary pressure (Pd) and Doppler velocity (U) were recorded in 29 patients at rest and during adenosine-induced hyperemia in a distal segment of a normal reference vessel and downstream of a single stenosis before and after revascularization. Conduit vessel tone was minimized with nitroglycerin. Microvascular resistance (MR) and SPc were calculated from Pd and U. In the reference vessel, SPc decreased from 21.5 m/s (SD 8.0) to 10.5 m/s (SD 4.1) after microvascular dilation (P < 0.0001). SPc was substantially higher in the presence of a proximal stenosis and decreased from 34.4 m/s (SD 18.2) at rest to 27.5 m/s (SD 13.4) during hyperemia (P < 0.0001), with a concomitant reduction in Pd by 20 mmHg and MR by 55.4%. The stent placement further reduced hyperemic MR by 26% and increased Pd by 26 mmHg but paradoxically decreased SPc to 13.1 m/s (SD 7.7) (P < 0.0001). Changes in SPc correlated strongly with changes in MR (P < 0.001) but were inversely related to changes in Pd (P < 0.01). In conclusion, the single-point method yielded erroneous predictions of changes in coronary wave speed induced by a proximal stenosis and distal vasodilation and is therefore not appropriate for estimating local wave speed in coronary vessels. Our findings are well described by a lumped reservoir model reflecting the "windkesselness" of the coronary arteries.

coronary hemodynamics; pulse wave velocity; microvascular resistance; intramyocardial pump; stenosis



Address for reprint requests and other correspondence: M. Siebes, Dept. of Medical Physics, Academic Medical Ctr., Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands (e-mail: m.siebes{at}amc.uva.nl)